Catalog excerpts
Jj i ' A Aurora™ Integrating Nephelometers Aerosol monitoring & atmospheric research
Open the catalog to page 1Today, right around the world, atmospheric scientists and environmental agencies rely on ECOTECH’s range of Aurora™ integrating nephelometers. They've proven themselves to not only be accurate, flexible and easy to use, but also transportable and designed to cope with the demands of use in remote locations. • Comprehensive range of nephelometers; from single or three wavelength integrating nephelometers to a polar three wavelength integrating nephelometer • The Aurora™ range offers total remote control including calibration • Rugged and robust. Proven capability in remote, unattended...
Open the catalog to page 2Affordable excellence AURO RA™ 1 0 0 0 Clear choice for visibility monitoring The Aurora™ 1000 is the perfect choice for any air quality monitoring system. It is a highly costeffective entry level instrument uncompromised in its reliability and designed to run in extreme conditions. Multiple options, features and accessories are available to be used in conjunction with the Aurora™ range. Refer to matrix table on page 7 for a list of options and compatibility. FE AT U RE S Single wavelength, available in 525 nm, 450 nm or 635 nm Wide measurement range (0.3 to 20,000 Mm-1) Fully automatic...
Open the catalog to page 3All-round capability AURO RA™ 3 0 0 0 Proven results for long term monitoring The Aurora™ 3000 is the favoured choice of researchers as it facilitates simultaneous measurement across three wavelengths, enabling wide and in-depth analysis of the interaction between light and aerosols. Its capabilities include integrating measurements of full scatter and backscatter, making it a perfect instrument for climate change research. Like its siblings, the Aurora™ 3000 has a range from 0.3 to 20,000 Mm-1. A high-precision option is also available, with a lower detectable limit of 0.1 Mm-1. FE AT U RE...
Open the catalog to page 4Best in class AURO RA™ 4 0 0 0 — P O L A R Measuring the aerosol phase function The Aurora™ 4000 builds on the same three wavelength capabilities as the Aurora™ 3000. This device provides measurements of light scattering within up to 18 user selectable angular sectors, using varied backscatter shutter positioning. This can be used to determine the phase function of aerosols, which is crucial to climate research and modelling. Despite its sophisticated capabilities, the Aurora™ 4000 maintains the same ease of use, maintenance and calibration as the rest of the Aurora™ range. FE AT U RE S...
Open the catalog to page 5ACS™ 1000 Innovation in hygroscopic study ECOTECH’s Aerosol Conditioning System (ACS™ 1000) can be used with most aerosol monitoring instruments, adjusting relative humidity with minimal particle loss to measure the effect of water uptake on the properties of aerosols. The ACS™ 1000 simultaneously controls differing relative humidity levels in two sample channels, allowing real-time measurement by parallel instruments for comparison. FEATURES I Sample RH controllable between 40 % and 90 % with minimal particle loss J Customisable flow and humidograms J Autoranging power supply 110-250 VAC,...
Open the catalog to page 6Options, features & accessories matrix o o o CM Mass Flow Control Option PM10 Inlet PART NO: H020449 PM25 Inlet PART NO: H020450 Automated Ball Valve Option PART NO: E011009 Upgrade LDL Option PART NO: E011007 External Pump Controller Kit PART NO: E011006 External Pump Kit PART NO: H020332 External Pump PART NO: P030004 Aerosol Conditioning System (ACS™ 1000) Ability to Log Raw Data Ability to Display Units in pg/m3 Using Spirant™ BAM or User K Factor Calibration Kit PART NO: H020331 External 12 Volt Cable Kit PART NO: C020022 Exhaust Tube Kit PART NO: H020330 Service Kit PART NO:...
Open the catalog to page 7A partnership with ECOTECH There’s a lot more to our Aurora™ range or ACS™ 1000 system than what comes in the box. ECOTECH provide continuous support for users right across the globe. Our own scientists and engineers can always be called upon for advice, knowledge and practical assistance, and they’re available in any time zone. We also facilitate user group meetings throughout the year, enabling a forum for researchers to share experiences and receive guidance from ECOTECH experts as well as peers. Our blog is the hub of a virtual network, also offering firmware and software updates....
Open the catalog to page 8All Ecotech catalogs and technical brochures
-
Operations & Maintenance
12 Pages
-
Environmental Monitoring
16 Pages
-
ORION
6 Pages
-
VOC1000
1 Pages
-
FUSION
6 Pages
-
DUO
6 Pages
-
CUBE
6 Pages
-
NO2 Analyser
8 Pages
-
Serinus 51 SO2/H2S Analyser
2 Pages
-
BLAST MONITORING Solutions
4 Pages
-
Serinus Cal
8 Pages
-
SPECTRONUS analyzer
12 Pages
-
ECOTECH Company Profile
16 Pages
-
WINAQMS
4 Pages
-
PROTINUS 1000
2 Pages
-
NH3 Analyser Serinus 44
2 Pages
-
EC9843 NOy analyzer
2 Pages
-
EC9820T CO2 trace analyzer
2 Pages
-
SO2 Analyser EC9850T
2 Pages
-
SO2 Analyser EC9850
2 Pages
-
SO2 Analyser Serinus 50
2 Pages
-
NOx EC9841AS
2 Pages
-
NOx EC9841
2 Pages
-
CO Analyser EC9832
2 Pages
-
CO Analyser Serinus 30H
2 Pages
-
CO Analyser Serinus 30
2 Pages
-
Serinus 10
2 Pages
-
SERINUS Gas Analyser Series
4 Pages
-
GasCal 1100 gas calibrator
2 Pages
-
WinAQMS Data Logger
4 Pages
-
Serinus 10 Ozone Analyzer
2 Pages
-
HiVol 3000 PUF Sampler
2 Pages
-
HiVol 3000 XAD Sampler
2 Pages
-
Converters
2 Pages
Archived catalogs
-
Environmental Monitoring 2019
16 Pages
-
Corporate Profile
6 Pages
-
EC9830T CO trace analyzer
2 Pages
-
EC9811 Ozone photometer
2 Pages
-
EC9841T NOx trace analyzer
2 Pages