The Aurora range of integrating nephelometers
8Pages

{{requestButtons}}

Catalog excerpts

The Aurora range of integrating nephelometers - 1

Jj i ' A Aurora™ Integrating Nephelometers Aerosol monitoring & atmospheric research

Open the catalog to page 1
The Aurora range of integrating nephelometers - 2

Today, right around the world, atmospheric scientists and environmental agencies rely on ECOTECH’s range of Aurora™ integrating nephelometers. They've proven themselves to not only be accurate, flexible and easy to use, but also transportable and designed to cope with the demands of use in remote locations. • Comprehensive range of nephelometers; from single or three wavelength integrating nephelometers to a polar three wavelength integrating nephelometer • The Aurora™ range offers total remote control including calibration • Rugged and robust. Proven capability in remote, unattended...

Open the catalog to page 2
The Aurora range of integrating nephelometers - 3

Affordable excellence AURO RA™ 1 0 0 0 Clear choice for visibility monitoring The Aurora™ 1000 is the perfect choice for any air quality monitoring system. It is a highly costeffective entry level instrument uncompromised in its reliability and designed to run in extreme conditions. Multiple options, features and accessories are available to be used in conjunction with the Aurora™ range. Refer to matrix table on page 7 for a list of options and compatibility. FE AT U RE S Single wavelength, available in 525 nm, 450 nm or 635 nm Wide measurement range (0.3 to 20,000 Mm-1) Fully automatic...

Open the catalog to page 3
The Aurora range of integrating nephelometers - 4

All-round capability AURO RA™ 3 0 0 0 Proven results for long term monitoring The Aurora™ 3000 is the favoured choice of researchers as it facilitates simultaneous measurement across three wavelengths, enabling wide and in-depth analysis of the interaction between light and aerosols. Its capabilities include integrating measurements of full scatter and backscatter, making it a perfect instrument for climate change research. Like its siblings, the Aurora™ 3000 has a range from 0.3 to 20,000 Mm-1. A high-precision option is also available, with a lower detectable limit of 0.1 Mm-1. FE AT U RE...

Open the catalog to page 4
The Aurora range of integrating nephelometers - 5

Best in class AURO RA™ 4 0 0 0 — P O L A R Measuring the aerosol phase function The Aurora™ 4000 builds on the same three wavelength capabilities as the Aurora™ 3000. This device provides measurements of light scattering within up to 18 user selectable angular sectors, using varied backscatter shutter positioning. This can be used to determine the phase function of aerosols, which is crucial to climate research and modelling. Despite its sophisticated capabilities, the Aurora™ 4000 maintains the same ease of use, maintenance and calibration as the rest of the Aurora™ range. FE AT U RE S...

Open the catalog to page 5
The Aurora range of integrating nephelometers - 6

ACS™ 1000 Innovation in hygroscopic study ECOTECH’s Aerosol Conditioning System (ACS™ 1000) can be used with most aerosol monitoring instruments, adjusting relative humidity with minimal particle loss to measure the effect of water uptake on the properties of aerosols. The ACS™ 1000 simultaneously controls differing relative humidity levels in two sample channels, allowing real-time measurement by parallel instruments for comparison. FEATURES I Sample RH controllable between 40 % and 90 % with minimal particle loss J Customisable flow and humidograms J Autoranging power supply 110-250 VAC,...

Open the catalog to page 6
The Aurora range of integrating nephelometers - 7

Options, features & accessories matrix o o o CM Mass Flow Control Option PM10 Inlet PART NO: H020449 PM25 Inlet PART NO: H020450 Automated Ball Valve Option PART NO: E011009 Upgrade LDL Option PART NO: E011007 External Pump Controller Kit PART NO: E011006 External Pump Kit PART NO: H020332 External Pump PART NO: P030004 Aerosol Conditioning System (ACS™ 1000) Ability to Log Raw Data Ability to Display Units in pg/m3 Using Spirant™ BAM or User K Factor Calibration Kit PART NO: H020331 External 12 Volt Cable Kit PART NO: C020022 Exhaust Tube Kit PART NO: H020330 Service Kit PART NO:...

Open the catalog to page 7
The Aurora range of integrating nephelometers - 8

A partnership with ECOTECH There’s a lot more to our Aurora™ range or ACS™ 1000 system than what comes in the box. ECOTECH provide continuous support for users right across the globe. Our own scientists and engineers can always be called upon for advice, knowledge and practical assistance, and they’re available in any time zone. We also facilitate user group meetings throughout the year, enabling a forum for researchers to share experiences and receive guidance from ECOTECH experts as well as peers. Our blog is the hub of a virtual network, also offering firmware and software updates....

Open the catalog to page 8

All Ecotech catalogs and technical brochures

  1. ORION

    6 Pages

  2. VOC1000

    1 Pages

  3. FUSION

    6 Pages

  4. DUO

    6 Pages

  5. CUBE

    6 Pages

  6. NO2 Analyser

    8 Pages

  7. Serinus Cal

    8 Pages

  8. WINAQMS

    4 Pages

  9. NOx EC9841AS

    2 Pages

  10. NOx EC9841

    2 Pages

  11. Serinus 10

    2 Pages

  12. Converters

    2 Pages

Archived catalogs