CONDENSING BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL ECODENSE WT 65 ECODENSE WT 80 ECODENSE WT 100 ECODENSE WT 115 ECODENSE WT 125 ECODENSE WT 150
Open the catalog to page 1DEAR USER, The Condensing Boilers ECODENSE WT 65, ECODENSE WT 80, ECODENSE WT 100, ECODENSE WT 115, ECODENSE WT 125, ECODENSE WT 150 are constructed and manufactured according to the most advance technological inventions and the safety rules. It is easy to use for our customers. We recommend that you read this manual and safety warnings thoroughly before the use of the device in order to ensure safe, cost effective and environmental-friendly use. If you encounter any issue that is not explained clearly in this manual or you could not understand, please contact with our service department....
Open the catalog to page 2WARNINGS Warning Symbols and Descriptions
Open the catalog to page 4General Safety Rules • All personnel engaged in installation, disassembly, commissioning, operation, control, maintenance and repair should have received the necessary training and fully read and understood this manual. • No changes that might damage the safety of the device must be made by persons and/or organizations on the device. • All operation, commissioning and installation works (except for burning adjustment) should be carried out when the device is not operating and after disconnecting the power supply. Noncompliance with these rules may lead to serious bodily injuries and even...
Open the catalog to page 5TERMS OF WARRANTY Main and auxiliary equipment and all components used in ECODENSE WT 65, ECODENSE WT 80, ECODENSE WT 100, ECODENSE WT 115, ECODENSE WT 125, ECODENSE WT 150 Condensing Boilers are guaranteed for 1 year by TERMO ISI SİSTEMLERİ A.Ş. starting from the date of commissioning under the maintenance, adjustment, operating conditions and relevant mechanic, chemical and thermal effects explained herein. Please note that this warranty is only valid if the device(s) is commissioned and maintained by our authorized services. Our company reserves the right to make any modifications on the...
Open the catalog to page 6GENERAL CHARACTERISTICS OF CONDENSING BOILER ECODENSE WT 65, ECODENSE WT 80, ECODENSE WT 100, ECODENSE WT 115, ECODENSE WT 125, ECODENSE WT 150 are heating devices operating with natural gas or LPG with a very low suction power, and equipped with high-duty, premix condensing control system with microprocessor. The boiler is composed of a heat exchanger with aluminum cooling fins and a steel premix burner equipped with ignition and ionization flame control, modulating fan and gas valve. ECODENSE WT 65, ECODENSE WT 80, ECODENSE WT 100, ECODENSE WT 115, ECODENSE WT 125, ECODENSE WT 150 are...
Open the catalog to page 7ECODENSE Components ECODENSE WT 65 - ECODENSE WT 80 No. Material 1 Venturi 7 Automatic air relief cock 8 Water pressure sensor 9 Water flow sensor 10 Condensing water collection tray 16 Heater circuit return 17 Heater circuit supply 19 Condensing water release outlet 20 Condensing water trap
Open the catalog to page 8ECODENSE WT 100 - ECODENSE WT 115 - ECODENSE WT 125- ECODENSE WT 150 No. Material 1 Venturi 7 Automatic air relief cock 8 Water pressure sensor 9 Water flow sensor 10 Condensing water collection tray 16 Heater circuit return 17 Heater circuit supply 19 Condensing water release outlet 20 Condensing water trap
Open the catalog to page 9ECODENSE CONDENSING BOILER RADIATOR HYDRAULIC P&ID SENSORS ve MODULES 1_ Outside Sensor ( QAC34 ) 2. Inlet Strap-on lemperature Sensors ( QAD36 )
Open the catalog to page 10ECODENSE CONDENSING BOILER RADIATOR + BOILER SENSORS ve MODULES HYDRAULIC P&ID 1. Outside Sensor ( OAC34 ) 2. Inlot Strap-on Temperature Sensors [ QAD36 )
Open the catalog to page 11CLOSED CIRCUIT COMPONENTS Balance Tank Balance Tank (Separator) must be vertical. Advantages: Ø No hydraulic response occurs between the boiler circuit and the heating circuit. Ø Boilers and heating zones operate under suitable water flow. Sizing of Balance Tank: Ø In order to ensure healthy operation of the balance tank, accurate sizing must be made. Ø The boiler’s exit water temperature should be measured on the upper part of balance tank. Ø For this, a ½” muff should be welded onto tank, and also an air relief cock should be mounted. Ø Dimensions shown in the picture represent minimum...
Open the catalog to page 18Sizing Table For Expansion Tank
Open the catalog to page 19Expansion Tank Expansion tank fore pressures must be adjusted according to system. Expansion tank should be placed parallel to circuit return line. Manometer A manometer with capacity of at least 0 to 6 bar must be connected to system. Manometer should be placed to easily visible spot from filling point, preferably same point as expansion tank. Strainer Any dirt or residue in circuit water causes damage got boiler and circuit components and decreases efficiency by reducing heat transfer. In order to prevent this problem a strainer must be connected to circuit. Air Separator The air in the...
Open the catalog to page 20WATER QUALITY 1. Before connection of condensing boilers any dirt and residue in circuit must be cleaned. 2. Refined water must be used while adding water to heating circuit due to any loss in closed circuit. 3. Permitted water hardness for water used in water circuit must comply with VDI 2035 standard. The lime dissolved in water, settles on hot surfaces and forms an insulation layer when water temperature rises. This prevents heat transfer and high temperature might damage the heat exchanger. If boiler water cycles through water circuit, all circuit water must meet above requirements. If...
Open the catalog to page 21TECHNICAL DATA Capacity Table ECODENSE WT SERIES WALL TYPE CONDENSING BOILER
Open the catalog to page 22Condensing Boiler Dimensions Noise Level When the condensing boiler is in operation, the maximum noise level released is <70 dBA. The noise level value corresponds to the value measured with semi-anekoik (semi-unreflecting acoustic) room testing according to the product standards at the time of expansion of the smoke release system, when the condensing boiler operates at the maximum heating power.
Open the catalog to page 23CONDENSING BOlLER HANDLING INFORMATION • Prevent strong impacts on top of the product and vibration while handling the product. • Do not leave the product in wet environment. Device must be shipped in original packaging! A Clean the inside of fuel line thoroughly before installing the burner to the fuel line. Any X|\ damage that may occur due to solid objects and metal particles from the fuel line shall not be covered by our company.
Open the catalog to page 24All Ecostar Burners catalogs and technical brochures
-
MONOBLOCK GAS BURNERS
39 Pages
-
DUCT BURNERS
22 Pages
-
FPB series
34 Pages
-
SHG series
23 Pages
-
Process burners 2017
12 Pages
-
grm series burners 2017
8 Pages
-
Duct burners 2017
4 Pages
-
Monoblock Burners 2017
108 Pages
-
Fuel-Oil Burners
8 Pages
-
Hot Air Generato
2 Pages
-
Dual Burners
8 Pages
-
brulorler-ecostar-gaz
8 Pages
-
Technical Catalogue
288 Pages
-
CIB DIB DSE MIB for Industry
20 Pages
-
Filtering,Pumping,Heating
2 Pages
-
INDUSTRIAL BURNERS
2 Pages
-
Gazoram Drying Burners
8 Pages
-
Portable Heaters
6 Pages
-
Diesel Burners
8 Pages
-
2013 Company
19 Pages
-
GAS PROCESS BURNERS
8 Pages
-
light oil burner
8 Pages
-
HEAVY OIL BURNER
8 Pages
-
DUAL FUEL MONOBLOCK BURNER
8 Pages
-
INDUSTRIAL BURNERS
8 Pages
Archived catalogs
-
ECOSTAR Duct Burners
1 Pages