MRVB

MRVB

MRVB

Product catalog summary
Overview
The ECONEX Manual Reset Shut-Off Valves, Series MRVB, are normally closed solenoid valves designed for high operating pressures and flow capacities. They are suitable for controlling gases from the 1st, 2nd, and 3rd families, as well as air. Available sizes include Rp ½ and Rp ¾.

Specifications
  • Valve Body: Brass
  • Trim: Stainless Steel
  • Seat Disc: Buna "N"
  • Standard Supply Voltage: 230 Vac (options for 110 Vac, 24 Vac, 24 V.D.C., 12 V.D.C.)
  • Frequency: 50 – 60 Hz
  • Duty Cycle: Continuous
  • Enclosure: IP 65 - IEC 529
  • Ambient Temperature: -10° to +60°C
  • Coil Orientation: 360°

Features
  • Normally closed operation
  • Quick closing
  • Installation in any position
  • Quiet operation
  • Resin-moulded coil
  • D.C. current with rectifier inside the plug connector

Operating Principle
The electromagnetic coil releases the shutting device when de-energized, interrupting the gas flow. The coil can be energized by a gas detector or another safety device. The shut-off valve can be manually reset only if the coil is energized.

Installation Instructions
  1. Ensure all operating data on the valve label match the system.
  2. Remove protection plugs from the valve.
  3. Ensure the pipeline is free from impurities and aligned with the valve body.
  4. Apply sealing material to the external thread of the pipeline only.
  5. Respect the flow direction indicated by the arrow on the valve body.
  6. Install the valve horizontally or vertically, ensuring the coil is not turned downwards.
  7. Use the correct wrench for installation, not the coil as a lever.
  8. Ensure the coil is energized before resetting the valve.

Maintenance
The equipment is maintenance-free.

Warnings
Read the operating instructions before use. Installation must be performed by skilled and authorized technicians. All data are subject to change without notice.
See more

Catalog excerpts

MRVB-1

MANUAL RESET SHUT - OFF VALVES Series MRVB…NC ECONEX Manual Reset Shut-Off valves Normally Closed of the series MRVB are a new-concept powerful solenoid capable of functioning at higher operating pressures and flow capacities than most comparable valves now available. MRVB valves are available in the following sizes: Rp ½ and Rp ¾. They are particularly suitable for the control of gases belonging to the 1st, 2nd and 3rd family and of air. Valve body : brass Standard supply voltage : 230 Vac Trim : stainless steel On request : 110 Vac Seat disc : Buna "N" 24 Vac 24 V.D.C. / 12 V.D.C. Connections : Rp ½ and Rp ¾ according to ISO 7-1 Frequency : 50 – 60 Hz Orifice size : 13 mm Duty cycle : continuous Inlet pressure : 500 mbar Connector : DIN 43650 [ISO 4400] Pg 11, with rectifier Closing time : < 1 second Cable inlet : adjustable 90° by 90° Ambient Enclosure : IP 65 - IEC 529 temperature : - 10° ÷ + 60° C Coil orientation : 360° .. Normally closed operation .. Quick closing .. Installation in any position [see installation and operating instructions] .. Quiet operation .. Resin-moulded coil .. D.C. current with rectifier inside the plug connector

 Open the catalog to page 1
MRVB-2

SIZE Pipe [Rp] Orifice Ø [mm] KVs Max. operating pressure [mbar] Rating [VA] Coil type MODEL 230 Vac -50/60Hz ½ 13 2,83 MRVB15CNCPO1 ¾ 13 3 500 18 P01 MRVB20CNCPO1 NOTE In the model code, replace the VII letter with B for 115 Vac / 50 - 60 Hz , with A for 24 Vac / 50 - 60 Hz, with F for 12 V D.C. and with E for 24 V D.C. OPERATING PRINCIPLE The electromagnetic coil releases the shutting device if de-energized and interrupts the gas flow. Coil can be energized either by a gas detector or by another safety device. For opening the shut-off valve pull the knob placed over the coil upwards making...

 Open the catalog to page 2
MRVB-4

WARNING PLEASE READ THE OPERATING INSTRUCTIONS BEFORE USE! THIS EQUIPMENT MUST BE INSTALLED ACCORDING TO THE PRESCRIPTIONS IN FORCE! Installation must be carried out exclusively by skilled and authorized service technicians. 1. Make sure that all operating data indicated on the manual reset valve label correspond to those of the system. 2. Remove the protection plugs from the manual reset valve. 3. Before installing the manual reset valve make sure that the pipeline is free from impurities and perfectly aligned with the valve body. The pipeline must be vibration-free. 4. The sealing material...

 Open the catalog to page 4

Archived catalogs

  1. MPV series

    4  Pages

  2. BSV

    4  Pages

  3. SVB

    4  Pages

  4. SVS

    4  Pages

  5. GDH

    4  Pages

  6. GMM

    2  Pages

  7. Ball valves

    2  Pages

  8. AB1 series

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.