Product catalog summary
Overview: The document describes a patented process for shredding and sterilizing infectious waste using saturated steam. The process is fully enclosed, automated, and made of stainless steel, eliminating intermediate waste handling.
Process Description: Contaminated waste is loaded into an upper chamber where it is shredded into small pieces. The shredded material then drops into a lower treatment chamber. The waste and machine parts are steam heated to 138°C (280°F) and pressurized to 3.5 bar (51 psi) for sterilization.
Cycle Details: The process cycle lasts 45 minutes, is fully automated, and monitored by a computerized control system. A batch report is printed and recorded at the end of each cycle, detailing sterilizing parameters.
Outcome: The final product is safe for recycling or disposal as ordinary waste. The process achieves microbial inactivation of 10^8 and reduces waste volume by up to 80%.
Approval: The process is approved by the Higher Council of Public Health of France under the Ministry of Health and the Ministry of the Environment.
Specifications: The system has a process volume capacity of 2500 liters per cycle. Dimensions are 490 x 460 x 640 cm (16.1 x 15.1 x 21 ft) with a shipping weight of 5200 kg. Maximum weight when filled with water for a hydraulic test is 10,500 kg. Stress is 3.5 kg/cm², steam pressure is 8 bar, and maximum steam flow is 500 kg/h. Compressed air is 6 bar, and electricity requirement is 380 V / 3-Phase 35 kW.
Operating Characteristics: Average cycle time is 45 minutes with a process volume capacity of 2500 liters. Average waste density is 100 - 150 kg/m³, and average process weight capacity is 250 - 375 kg/cycle (551 - 827 lb/cycle). Consumption per cycle includes 40 kg of steam, 9 kWh of electricity, and 50 liters of water.
Contact Information: Address: 28 rue Sébastopol, 59100 Roubaix, France. Phone: +333 20 70 98 65. Fax: +333 20 36 28 05. Email: [email protected]. Website: www.ecodas.com.
See more

Catalog excerpts

T2000-1

- Process volume capacity 2500 L per cycle. STAAT NDARD Our patented process is designed to shred and sterilize infectious waste by saturated steam. Shredding and sterilization are achieved in one fully enclosed and automated, stainless steel, system with no intermediate waste handling. The contaminated waste is loaded into the upper chamber where a heavy-duty shredder reduces the waste into small pieces. Using gravity, the processed material drops into the lower treatment chamber. After shredding, waste and all the inner parts of the machine are steam heated to 138°C (280 F) and pressurized to 3,5 bar (51 psi). Sterilization is achieved by maintaining a temperature of 138°C (280 F) at the core of the waste for 10 minutes. After the cooling process, the final product is safe to recycle or to dispose as ordinary waste. Waste are both sterilized (Microbial inactivation = 108) and volumereduced by up to 80 %. The 45 minutes duration of an average cycle process is fully automated and totally monitored. A computerized control system scans the process and automatically prints and records on a memory card a batch report at the end of each cycle with the essential sterilizing parameters for accurate record keeping. Approved by the Higher Council of Public Health of France under the direction of the Ministry of Health and the Ministry of the Environmen

 Open the catalog to page 1
T2000-2

- Process volume capacity 2500 L per cycle General Characteristics 490 x 460 x 640 cm 16,1 x 15,1 x 21 ft 5200 kg 10500 kg 3,5 kg/cm2 Operating Characteristics Average Cycle Time Process Volume Capacity Average Waste Density Average Process Weight Capacity Microbial Inactivation Waste Volume Reduction Consumption / cycle Steam 40 kg [email protected] www.ecodas.com ENGINEERED SOLUTIONS FOR HEALTHCARE & THE ENVIRONMENT

 Open the catalog to page 2