Technical Specifications
  • Brand: Eco ice
  • Type: AKM 25 kW
  • Refrigerant: Ammonia / Water
  • Refrigerating Capacity: 25 kW
  • Coefficient of Performance (COP): ≥ 0.38

Coolant Circuit
  • Inlet Temperature: -3°C
  • Outlet Temperature: -6°C
  • Volume Flow (Water / Glycol): 7.9 m³/h
  • Connection: DN 50

Heating Water Circuit
  • Heating Capacity: 56 kW
  • Inlet Temperature: 90 – 95°C
  • Outlet Temperature: 80 – 85°C
  • Volume Flow: 5.9 m³/h
  • Connection: DN 50

Cooling Water Circuit
  • Re-cooling Power: 91 kW
  • Inlet Temperature: 25°C
  • Outlet Temperature: 30°C
  • Volume Flow: 15.7 m³/h
  • Connection: DN 65

Electrical Data
  • Voltage / Frequency: 400 V / 50 Hz
  • Power Input: 1.6 kWel

Dimensions and Weight
  • Dimensions (L/W/H): 800 / 1200 / 2000 mm
  • Operating Weight: 550 kg

Contact Information
  • Executive Director: Dr. Günter Bellmann
  • Project Engineer: Dipl.-Ing. Silvio Knorr
  • Address: Am Heiligen Holz 10, 04552 Borna
  • Telephone: +49 3433 74667-0
  • Email: [email protected]
  • Website: www.eco-ice.net

Additional Information

The document includes a 3D illustration of the AKM in combination with possible peripheral devices. The refrigerating capacity and COP are dependent on heating water and recooling temperature.

Issue Date: 09/2015

See more

Catalog excerpts

Absorption refrigerator Ecoice Kälte GmbH-1

Absorption refrigerator Ecoice Kälte GmbH Refrigerating capacity1 Technical Data Sheet Coolant circuit Inlet temperature Volume flow (Water / glycol) Heating capacity Inlet temperature Outlet temperature Volume flow Re-cooling power Inlet temperature Outlet temperature Volume flow Voltage / Frequency Power input Length / Width / Height Refrigerant: Ammonia / Water Outlet temperature Operating weight Heating water circuit Product image: Cooling water circuit Electrical data Executive director: Dr. Günter Bellmann Telephone: +49 3433 74667-0 e-Mail: [email protected] Project engineer: Dipl.-Ing. Silvio Knorr Telephone: +49 3433 74667-13 e-Mail: [email protected] Am Heiligen Holz 10, 04552 Borna Tel: +49 3433 74667-0, www.eco-ice.net [email protected] 3d-Illustration of the AKM in combination with possible peripheral devices 1 depending on heating water and recooling temperature I

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.