1. Catalogs
  2. EC Sense GmbH
  3. EC4-HCl-30-01 Hydrogen Chloride Gas Sensor

EC4-HCl-30-01 Hydrogen Chloride Gas Sensor

EC4-HCl-30-01 Hydrogen Chloride Gas Sensor

EC4-HCl-30-01 Hydrogen Chloride Gas Sensor

Product catalog summary
Technical Specifications
The EC4-HCl-30-01 is an electrochemical 3-electrode sensor designed for detecting hydrogen chloride gas. It is suitable for industrial safety, leakage detection, emission monitoring, semiconductor industry, and warehouse logistics monitoring. Key features include no bias voltage, high selectivity, double-sealed housing for leakage protection, stable zero, linear output, high sensitivity, and low power consumption. It operates within a temperature range of -20°C to +55°C and is RoHS compliant.

Performance
The sensor has a sensitivity of -150 nA/ppm ± 50 nA/ppm, a zero current of ± 100nA, and a range of 0-30ppm with a maximum overload of 100ppm. It offers a resolution of less than 0.1 ppm and response times of T50 < 40s and T90 < 80s. The repeatability is 2% with linear output.

Operation
The sensor operates on an amperometric principle with a bias voltage of 0 mV and a recommended load resistor of 100 Ω. The warm-up time is less than 60 seconds.

Environmental Conditions
It functions in an operating temperature range of -20 to +55℃, humidity range of 15-95 %RH (non-condensing), and pressure range of 800 to 1200 hPa. The storage temperature is optimal between 4 to 6℃.

Lifetime and Warranty
The sensor has a long-term drift of less than 1% per month, an expected lifetime of over 2 years, and a zero drift in clean air of less than 1 ppm. The storage life is 6 months, and it comes with a 12-month warranty.

Cross Sensitivity
The sensor shows no response to methane and carbon dioxide at test concentrations, while it accurately detects hydrogen chloride at 1 ppm. Positive readings are expected for fluorine and hydrogen bromide.

Disclaimer and Warning
The datasheet includes a disclaimer about the accuracy of the performance data and a warning regarding the handling and disposal of the sensor. Users are advised to avoid cleaning with strong solvents and to follow local electronic waste recycling regulations.

Contact Information
EC Sense GmbH in Germany and Ningbo AQSystems Technology Co., Ltd. in China are the business centers for Europe, the rest of the world, and Asia respectively.
See more

Catalog excerpts

EC4-HCl-30-01 Hydrogen Chloride Gas Sensor-1

Electrochemical 3-Electrode Sensor EC4-HCl-30-01 Hydrogen Chloride Gas Sensor Datasheet Easy Gas Sensor Solutions

 Open the catalog to page 1
EC4-HCl-30-01 Hydrogen Chloride Gas Sensor-2

EC4-HCl-30-01 Hydrogen Chloride Gas Sensor Datasheet EC4-HCl-30 Hydrogen Chloride Gas Technical Specifications Performance Features No bias voltage Detects with high selectivity a wide variety of gases Double sealed housing for advanced leakage protection Stable zero Zero Current Maximum Overload Response Time Environment Operating Temperature Range Linear output Operating Humidity Range High sensitivity Operating Pressure Range Storage Temperature nA power consumption Wide operation temperature range of -20°C to +55°C Typical warm-up time in minutes RoHS compliant Typical Applications Industrial...

 Open the catalog to page 2
EC4-HCl-30-01 Hydrogen Chloride Gas Sensor-3

EC4-HCl-30-01 Hydrogen Chloride Gas Sensor Datasheet Test Concentration Sensor Reading Carbon Dioxide Hydrogen Chloride Hydrogen Bromide *Positive Reading Expected Note: 1) The above interference factors may vary due to different sensors and service life, please refer to the actual test results. 2) This table is not complete for all cross gases. Please contact us for other gases. 3) The above parameters are the test results at a temperature of 25°C, a relative humidity of 50%RH and a normal pressure environment. The performance of the sensor varies under different environmental conditions. If...

 Open the catalog to page 3
EC4-HCl-30-01 Hydrogen Chloride Gas Sensor-4

EC4-HCl-30-01 Hydrogen Chloride Gas Sensor Datasheet Disclaimer The EC Sense performance data stated above is based on data obtained under test conditions using the EC Sense gas distribution system and AQS test software. In the interest of continuous product improvement, EC Sense reserves the right to change design features and specifications without notice. We are not responsible for any loss, injury or damage caused by this. EC Sense assumes no responsibility for any indirect loss, injury or damage resulting from the use of this document, the information contained therein or any omissions or...

 Open the catalog to page 4
EC4-HCl-30-01 Hydrogen Chloride Gas Sensor-5

Business Centre Europe and the rest of the world Business Centre Asia EC Sense GmbH Wangener Weg 3 82069 Hohenschäftlarn, Germany Tel: +49(0)8178-99992-10 Fax: +49(0)8178-99992-11 Email: [email protected] www.ecsense.com, www.ecnose.de Ningbo AQSystems Technology Co., Ltd. F4-17 Building, Zhong Wu Technology Park No.228, Jin Gu Bei Road, Yinzhou District NingBo, Zhejiang Provence, P.R. China Post Code: 315100 Tel: +86(0)574 88097236, 88096372 Email: [email protected] www.ecsense.cn, www.ecnose.de EC4-HCl-30 Hydrogen Chloride Gas Sensor_Datasheet_V1.1_20230607 Copyright@2023 EC Sense GmbH

 Open the catalog to page 5
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.