The EC4-F2-5-01 Fluorine Gas Sensor is an electrochemical 3-electrode sensor designed for industrial safety, leakage detection, emission monitoring, and more. It features high selectivity, a double-sealed housing for leakage protection, stable zero, linear output, high sensitivity, and low power consumption. It operates within a temperature range of -20°C to +40°C and is RoHS compliant.

Performance
The sensor has a sensitivity of -260 nA/ppm ± 80 nA/ppm, a zero current of ± 20nA, and a range of 0-5ppm with a maximum overload of 10ppm. It offers a resolution of < 0.01 ppm and response times of T50 < 20s and T90 < 60s. The sensor is linear with a repeatability of 2%.

Operation
Operating on an amperometric principle with a bias voltage of 0 mV, it requires a recommended load resistor of 100 Ω and has a warm-up time of less than 60 seconds.

Environmental Conditions
The sensor functions in temperatures from -20 to +40℃, humidity from 15-95 %RH (non-condensing), and pressure from 800 to 1200 hPa. It should be stored between 0 to 20℃, optimally at 4 to 6℃.

Lifetime and Warranty
The sensor has a long-term drift of < 1 %/month, an expected lifetime of over 2 years, and a zero drift in clean air of < 1 ppm. It has a storage life of 6 months and a warranty of 12 months.

Cross Sensitivity
The sensor shows positive readings for gases like Bromine, Carbon Monoxide, Chlorine, Chlorine Dioxide, Iodine, and Nitrogen Dioxide, while showing no response to Methane and Carbon Dioxide. Sulfur Dioxide shows a negative reading.

Disclaimer and Warning
The datasheet includes a disclaimer about the accuracy of the data and a warning about the proper handling and disposal of the sensor. Users are advised to avoid cleaning with strong solvents and to follow local electronic waste recycling regulations.

Contact Information
EC Sense GmbH in Germany and Ningbo AQSystems Technology Co., Ltd. in China are the main contacts for Europe, the rest of the world, and Asia respectively.
See more

Catalog excerpts

EC4-F2-5-01 Fluorine Gas Sensor-1

Electrochemical 3-Electrode Sensor EC4-F2-5-01 Fluorine Gas Sensor Datasheet Easy Gas Sensor Solutions

 Open the catalog to page 1
EC4-F2-5-01 Fluorine Gas Sensor-2

EC4-F 2 -5-01 Fluorine Gas Sensor Datasheet EC4-F2-5 Fluorine Gas Technical Specifications Performance Features Detects with high selectivity a wide variety of gases Double sealed housing for advanced leakage protection Stable zero Zero Current Maximum Overload Response Time Environment Operating Temperature Range High sensitivity Operating Humidity Range Operating Pressure Range Storage Temperature Linear output Wide operation temperature range of -20°C to +40°C Typical warm-up time in minutes RoHS compliant Typical Applications Industrial Safety Leakage Detection Operation Operating Principle...

 Open the catalog to page 2
EC4-F2-5-01 Fluorine Gas Sensor-3

EC4-F 2 -5-01 Fluorine Gas Sensor Datasheet Test Concentration Sensor Reading Carbon Dioxide Carbon Monoxide Chlorine Dioxide Nitrogen Dioxide Sulfur Dioxide *Positive Reading Expected **Negative Reading Expected Note: 1) The above interference factors may vary due to different sensors and service life, please refer to the actual test results. 2) This table is not complete for all cross gases. Please contact us for other gases. 3) The above parameters are the test results at a temperature of 25°C, a relative humidity of 50%RH and a normal pressure environment. The performance of the sensor varies...

 Open the catalog to page 3
EC4-F2-5-01 Fluorine Gas Sensor-4

EC4-F 2 -5-01 Fluorine Gas Sensor Datasheet Disclaimer The EC Sense performance data stated above is based on data obtained under test conditions using the EC Sense gas distribution system and AQS test software. In the interest of continuous product improvement, EC Sense reserves the right to change design features and specifications without notice. We are not responsible for any loss, injury or damage caused by this. EC Sense assumes no responsibility for any indirect loss, injury or damage resulting from the use of this document, the information contained therein or any omissions or errors...

 Open the catalog to page 4
EC4-F2-5-01 Fluorine Gas Sensor-5

Business Centre Europe and the rest of the world Business Centre Asia EC Sense GmbH Wangener Weg 3 82069 Hohenschäftlarn, Germany Tel: +49(0)8178-99992-10 Fax: +49(0)8178-99992-11 Email: [email protected] www.ecsense.com, www.ecnose.de Ningbo AQSystems Technology Co., Ltd. F4-17 Building, Zhong Wu Technology Park No.228, Jin Gu Bei Road, Yinzhou District NingBo, Zhejiang Provence, P.R. China Post Code: 315100 Tel: +86(0)574 88097236, 88096372 Email: [email protected] www.ecsense.cn, www.ecnose.de EC4-F2-5 Fluorine Gas Sensor_Datasheet_V1.1_20230607 Copyright@2023 EC Sense GmbH