Overview
The document provides detailed information on ebro's eBi 100 and eBi 15 data loggers, designed for routine control of steam sterilizers, washer-disinfectors, and washer-disinfectors for endoscopes. These devices comply with German guidelines and ISO standards, ensuring reliable measurement and evaluation of sterilization processes.

Specifications
  • EBI 100-T100: Temperature data logger with a range of -40 °C to +150 °C and accuracy of ±0.3 °C.
  • EBI 100-TP231: Pressure/temperature data logger with a pressure range of 1 mbar to 4000 mbar and accuracy of ±15 mbar.
  • EBI 15: Bowie Dick Test data logger with temperature accuracy of ±0.1 °C.

Starter Sets
  • SL 1010: For bed pan washers, includes EBI 100-T100, pH tester, conductivity tester, software, and carrying case.
  • SL 1110: For washer-disinfectors and steam sterilizers, includes EBI 100-TP231, pH tester, conductivity tester, silicone protection box, software, and carrying case.
  • SL 1610: For routine control and Bowie Dick test, includes EBI 15, EBI 100-T100, software, and carrying case.
  • SL 1500: For Bowie Dick test in steam sterilizers, includes EBI 15, software, and carrying case.

Procedures and Software
The Winlog.med software facilitates data read-out and evaluation, providing automatic pass/fail results. It supports multiple data loggers and requires a computer with at least 1 GHz processor speed, 1 GB RAM, 1 GB free storage, USB 2.0, and Windows XP or 7.

Benefits
  • Easy use and documentation of tests.
  • Reusable after 500 cycles with service and calibration.
  • Conforms with ISO 17665, EN ISO 11140-4, and EN 285 standards.
  • Certified by TÜV Industrial Services and SMP.

Contact Information
ebro Electronic GmbH, Peringerstr. 10, 85055 Ingolstadt, Germany. Tel: +49 841 95478-0, Email: [email protected], Website: www.ebro.com
See more

Catalog excerpts

Data Loggers for Routine Control-1

Routine Control WASHER-DISINFECTORS / WASHER-DISINFECTORS FOR ENDOSCOPES / STEAM STERILIZERS / BEDPAN WASHERS CSSD | MEDICAL i HYGIENE CONTROL a xylem brand

 Open the catalog to page 1
Data Loggers for Routine Control-2

Routine control made easy with ebro data loggers EBI 100 data loggers With the EBI 100 data loggers, ebro offers reliable measurement devices for routine control of steam sterilizers, washer-disinfectors and washer-disinfectors for endoscopes according to German guidelines and ISO 15883. The data loggers are available in different versions including temperature or temperature / pressure loggers with and without external probes. They record the temperature and pressure variation over time during the washer-disinfector or sterilizer process and can easily be read out on a computer with the help...

 Open the catalog to page 2
Data Loggers for Routine Control-3

Electronic Bowie Dick Test with the EBI 15 data logger With the EBI 15 data logger, ebro has developed an easy to use and very reliable measurement system for comprehensive routine control of steam sterilizers as well as for the execution of the Bowie Dick Test according to EN ISO 11140-4 and ISO 17665. In addition, the system can check relevant sterilization parameters such as vacuum, compensation time, hold time and sterilization temperature as well as steam penetration. After completing the test, data read-out and graphic test evaluation is done with ebro’s Winlog.med software. EBI 15 Bowie...

 Open the catalog to page 3
Data Loggers for Routine Control-4

What does the EBI 15 accomplish? • Bowie Dick Test: The EBI 15 delivers clear results during daily checks of the air evacuation test and steam penetration test according to ISO 17665, EN ISO 11140-4 and DIN EN 285. • Easy use, evaluation and documentation of the Bowie Dick Test • Early warning system: The EBI 15 provides early identification of possible failures in steam-sterilizers. Even the smallest quantities of residual air that doesn`t lead to a failed Bowie Dick Test yet are detected. • Vacuum check: The EBI 15 allows a reasonable vacuum check also for sterilizers without pressure display...

 Open the catalog to page 4
Data Loggers for Routine Control-5

www.ebro.com Peringerstraße aß 10 mbH • ic Gm b D--8 ron ctro 505 Ele 5 5 In ro E go g eb lstt 11 01 ad tt ©2 Easy data read-out with Winlog.med software During the routine monitoring of washer-disinfectors, washer-disinfectors for endoscopes and steam sterilizers the pressure and temperature variation in time is documented with the help of the data loggers. During the evaluation, the software recognizes and checks all relevant phases of the sterilization. In addition, all of the required parameters are calculated and graphically displayed with the help of the software. Winlog.med software allows...

 Open the catalog to page 5
Data Loggers for Routine Control-6

Bowie Dick Test data logger data logger range Temperature accuracy Pressure measurement range Pressure accuracy Protection class Factory calibration ebro Electronic GmbH Peringerstr. 10 85055 Ingolstadt, Germany Tel +49 841 95478-0 Fax +49 841 95478-80 Internet: www.ebro.com E-Mail: [email protected] All names are registered tradenames or trademarks of ebro Electronic GmbH. Technical changes reserved. © 2013 ebro Electronic GmbH. February 2013

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.