Fans and drive concepts for rail technology Edition 2016-11 ebmpapst The engineer’s choice
Open the catalog to page 1About ebm-papst As a leader in technologies for ventilation and drive engineering, ebm-papst is in demand as an engineering partner in many sectors. With over 15,000 different products, we provide the right solution for just about any challenge. Our fans and drives are reliable, quiet and energy-efficient. Six reasons that make us the ideal partner: Our systems expertise. You want the best solution for every project. The interrelationships between ventilation and drive engineering must thus be considered as a whole. And that’s what we do – with motor technology that sets standards,...
Open the catalog to page 2Information Drive concepts ebm-papst ZEITLAUF Technology: - Accessories - Conn. diagrams - Technical parameters & scope ebm-papst agents Tractionized fans for railway applications 110 VDC Photo: Deutsche Bahn AG / Claus Weber Technical parameters & scope Conn. diagrams Drive concepts ebm-papst ZEITLAUF Tractionized fans for railway applications 400 VAC About ebm-papst ebm-papst: Your highly competent partner in rail engineering Fire safety in rail vehicles Tractionized fans for railway applications 24 VDC Tractionized fans for railway applications 110 VDC Tractionized fans for railway...
Open the catalog to page 3ebm-papst: Your highly competent partner in rail engineering Creating the ideal fan solution. Our advantage lies in the perfect interaction. The area of railways places particular requirements on a product. Fans developed uniquely for rail technology and for the specific field of application will help to achieve a high level of customer satisfaction in the long-term. Introducing standard products in rail vehicles is frivolous and sooner or later becomes expensive for the customer. To find the best solution for the individual rail use in each case, a comparison of the requirements in the field...
Open the catalog to page 4Information Concretely, this means that all the relevant components possess the test certificates they require and that they are all currently valid. Specific properties of the products‘ construction were also verified. The seven-part standard has the objective of protecting passengers and staff in case of fire on board and assuring evacuation. Part 2 of the standard describes the requirements for the degree of flammability of materials and components. ebm-papst subjected the products to voluntary testing and certification by TÜV SÜD. Tractionized fans for railway applications 400 VAC The test...
Open the catalog to page 5Technical parameters & scope Conn. diagrams Drive concepts ebm-papst ZEITLAUF Tractionized fans for railway applications 400 VAC Tractionized fans for railway applications 110 VDC Tractionized fans for railway applications 24 VDC Tractionized fans for railway applications - 24 VDC Information
Open the catalog to page 7EC dual centrifugal fan with housing, for railway applications, Ø 097 Technical features and electrical connection Sound power level Input current Input power Nominal data Voltage range Material: Housing and Impeller: plastic PA UL94 V0, black Degree of protection: Motor: IP 24 KM, Electronics: IP 66 / 69 K Insulation class: "B" Installation position: Any Mode: Continuous operation (S1) Bearings: Maintenance-free ball bearings Cable exit: Lateral Protection class: III Conformity with standards: See P. 4 Approvals: EAC Technical features: See electrical connections P. 80 Nominal voltage Air...
Open the catalog to page 8Information Tractionized fans for railway applications 24 VDC Tractionized fans for railway applications 110 VDC Tractionized fans for railway applications 400 VAC Cable (halogen-free): BETAtrans® GKW R 2,5 mm2, 2x crimped ferrules (brown, black) BETAtrans® GKW R 1,0 mm2, 4x crimped ferrules (yellow, orange, blue, white) Conn. diagrams Technical parameters & scope Drive concepts ebm-papst ZEITLAUF Terminal assignment: + UB (black) GND (brown) PWM/LIN (yellow) INVLIN (orange) ABSENK (blue) Diagnostic output (white
Open the catalog to page 9EC dual centrifugal fan with housing, for railway applications, Ø 097 Technical features and electrical connection Sound power level Input current Input power Nominal data Voltage range Material: Housing and Impeller: plastic PA UL94 V0, black Degree of protection: Motor: IP 24 KM, Electronics: IP 66 / 69 K Insulation class: "B" Installation position: Any Mode: Continuous operation (S1) Bearings: Maintenance-free ball bearings Cable exit: Lateral Protection class: III Conformity with standards: See P. 4 Approvals: EAC Technical features: See electrical connections P. 84 Nominal voltage Air...
Open the catalog to page 10Technical parameters & scope Conn. diagrams Drive concepts ebm-papst ZEITLAUF Tractionized fans for railway applications 400 VAC Terminal assignment: + UB (black) GND (brown) PWM/LIN (yellow) Diagnostic output (white) Cable (halogen-free): BETAtrans® 3 GKW 6 mm2, 2x crimped ferrules (brown, black) BETAtrans® 3 GKW 1 mm2, 2x crimped ferrules (yellow, white) Tractionized fans for railway applications 110 VDC Tractionized fans for railway applications 24 VDC
Open the catalog to page 11Nominal data EC axial fanfor railway applications, 0 300 Material: Housing and Impeller: plastic PA UL94 V0, black Direction of air flow: "V" (sucking over rotor) Degree of protection: Motor: IP 24 KM, Electronics: IP 66 / 69 K Insulation class: "B" Installation position: Any Mode: Continuous operation (S1) Bearings: Maintenance-free ball bearings Cable exit: Lateral Protection class: III Conformity with standards: See P. 4 Approvals: EAC Technical features: See electrical connections P. 80 Curves: 350 300 250 200 150 100 50 A J2 Q_ Air performance measured as per: ISO 5801, Installation...
Open the catalog to page 12Information Tractionized fans for railway applications 24 VDC Tractionized fans for railway applications 110 VDC Tractionized fans for railway applications 400 VAC Drive concepts ebm-papst ZEITLAUF Accessories Conn. diagrams X View X: 3 2 1 = + UB (black) 2 = GND (brown) 1 3 = PWM/LIN (yellow) 6 4 = INVLIN (orange) 4 X 5 5 = ABSENK (blue) 6 = Diagnostic output (white) Lead connection with plug tyco Junior Power Timer 1-962349-1, 6-pole, coded. Mating plug tyco 1-963212-1 not included in delivery. Technical parameters & scope
Open the catalog to page 13All EBMPAPST catalogs and technical brochures
-
RER 125-19/12 N
4 Pages
-
RER 120-26/14/2 TDP
4 Pages
-
REF 100-11/18 H
4 Pages
-
5958
4 Pages
-
4656 N
4 Pages
-
4118 N/2H8P
4 Pages
-
4112 NH3
4 Pages
-
3850
4 Pages
-
3600
4 Pages
-
3414 NGH
4 Pages
-
3214 JH
4 Pages
-
3412 NGMV
5 Pages
-
3218 JH4
4 Pages
-
3218 JN
4 Pages
-
255 M
4 Pages
-
252 N
4 Pages
-
255 N
4 Pages
-
252 H
4 Pages
-
255 H
4 Pages
-
RG 160-28/18/ 2NTDHHP
4 Pages
-
RadiFit EC centrifugal fans.
8 Pages
-
DC RadiCal centrifugal fans
8 Pages
-
Retrofit - the right way!
3 Pages
-
New EC blower from ebm-papst
2 Pages
-
Product Catalogue 2019-03
74 Pages
-
RadiPac
8 Pages
-
RadiCal
12 Pages
-
RadiPac EC centrifugal fans
136 Pages
-
Condensing boiler technology
48 Pages
-
G2E146-DW07-01
9 Pages
-
G2E180-EH03-01
10 Pages
-
G4D225-FK10-03
10 Pages
-
G4D250-DC10-03
10 Pages
-
G4E160-AB01-01
9 Pages
-
EC/AC axial fans - AxiCool
56 Pages
-
Compact fans for AC and DC
192 Pages
-
Axial fans version 07
436 Pages
-
Compact fans for AC, DC and EC
272 Pages
-
RadiCal
2 Pages
-
S FORCE
192 Pages
-
ECI 63
14 Pages
-
ATEX
2 Pages
-
ErP 2015
3 Pages
-
PLUG FANS
76 Pages
-
Energy-saving fans
56 Pages
-
AC axial fans - HyBlade®
48 Pages
-
EC axial fans - HyBlade®
48 Pages
-
AC axial fans
31 Pages
-
AC and DC voltage compact fans
192 Pages
-
AC axial fans, AC diagonal fans
10 Pages
-
ECI 63 modular drive series
14 Pages
-
Centrifugal fans and blowers
616 Pages
-
Square shaded-pole motors
15 Pages
-
ACmaxx
5 Pages
-
AC axial fans, AC diagonal fans
10 Pages
-
AC centrifugial fans
78 Pages
-
Energy-saving motors
14 Pages
-
AC axial fans, A series
22 Pages
-
AC axial fans, Kseries
26 Pages