Customized drive systems I Components I assembly Drive solutions I Industrial drive engineering 2018-06 ebmpapst The engineer’s choice
Open the catalog to page 1Information About ebm-papst Definitions for motors AC motors Information about AC motors KM 40XX / 2-pole KM 40XX / 4-pole KM 43XX / 2-pole KM 43XX / 4-pole BLDC motors BG 43XX Control electronics DC motors M28XX M80XX Gearheads Performax® 32 (planetary gearhead) Optimax 63 (planetary gearhead) Flatline 78 (spur gearhead) Accessories Optical encoder system Brakes Power supply unit Standards and guidelines Operating factor, lifetime, efficiency ebm-papst around the world
Open the catalog to page 3About ebm-papst. As technological leader for ventilation and drive engineering, ebm-papst is in demand as an engineering partner in many industries. With over 15,000 different products, we provide the right solution for just about any challenge. Our fans and drives are reliable, quiet and energy-efficient. Six reasons that make us the ideal partner: Closeness to our customers. ebm-papst has 25 production locations worldwide (including facilities in Germany, China and the USA), together with 49 sales offices, each of You want the best solution for every project. The interrelationships which...
Open the catalog to page 4Information AC motors DC motors BLDC motors Our success story to becoming market leader and technological innovator. 1963 Elektrobau Mulfingen GmbH & Co. KG founded by Gerhard Sturm and Heinz Ziehl. 1965 Development of the first compact fan in the field of EC-/DC-technology. 1966 The ebm-papst success story started to take off with the release of the new 68 motor. 1972 The first foreign subsidiary was founded in Sweden. 1988 Gerhard Sturm receives the German Cross of Merit. 1990 The sixty millionth external rotor fan was produced. 1992 Acquisition of PAPST Motoren GmbH in St. Georgen. 1997...
Open the catalog to page 5Continuous stall power PBn0 [W] Is an approximate value for the voltage-independent maximum permitted output (P=U x I) that can be taken from the DC voltage source in holding status. Permissible peak torque short-term Mmax [mNm] Is the torque which the motor can usually deliver in a short time. Permissible peak current, motor lead Imax [A] Is the current that must flow in to the motor lead as a peak value to achieve the short-time peak torque. Induced voltage Uimax [V/1 000 rpm] Maximum value of the induced voltage between two motor leads at 1 000 rpm. It is a dimension for the...
Open the catalog to page 6Starting torque [mNm] Is the torque that can be delivered over a short time when the motor is started based on the electromagnetic motor characteristics and the set current limitation. Effective torque Meff [mNm] For cycle operation (e.g. “S5” operating mode - intermittent duty with the effect of the startup losses and the losses due to electrical braking on the heating), the effective torque corresponding to continuous operation (“S1” operating mode) is determined according to the following formula: At an ambient temperature of 40°C this effective torque must not be greater than the...
Open the catalog to page 7General information BLDC motors ebm-papst around the world
Open the catalog to page 9Information about AC motors. High quality sintered cup slide bearings with lubricant depot are Nominal voltage: 230 V, 50 Hz adaptation for other voltages and used by default, suitable for ambient temperatures of approx. frequencies is generally possible. Motors designed for 50 Hz can 0 to 60°C. Proven bearing systems are available for lower or higher usually also be operated at the same voltage with 60 Hz (see temperatures. For increased axial or / and radial loads, such as diagram). However, due to the changed rpm/ torque ratio, the vertical shaft positions, belt drives or the like, an...
Open the catalog to page 10Technical information of shaded pole motors EM - Asymmetrical setup - 2-pole with short circuit rotor - Simple and robust - Self-starting - Maintenance and radio interference-free You can get additional information about shaded pole motors EM by request. Technical information of capacitors KM - 2- or 4-pole single-phase motors with short circuit rotor - Winding, 2-stranded, with switched operating capacitor auxiliary phase Additional information about capacitor motors KM can be found on the following pages of the catalogue (page 12-19).
Open the catalog to page 11- Clockwise directional rotation (see connection diagram) - Symmetrical winding, also suitable for counter-clockwise rotation - Continuous operation S1 - Ball bearing - Insulation class F (VDE/EN) Characteristic curve
Open the catalog to page 12O Screw-in depth max. 8 For thread-forming screws according to DIN 7500 Electrical connection Connection cable Color brown (bn) light blue (lbu) black (bk) Function Phase Neutral conductor Auxiliary phase Cable length 180 ± 20 from motor Cable end 6 ± 2 with ferrules Change of the rotating direction is possible by polarity reversal of the wires bk bn For motor-gearbox combinations, depending on the choice of the single components, the maximum allowable torque (gearbox) can be exceeded or respectively not reached.
Open the catalog to page 13- Clockwise directional rotation (see connection diagram) - Symmetrical winding, also suitable for counter-clockwise rotation - Continuous operation S1 - Ball bearing - Insulation class F (VDE/EN) Characteristic curve
Open the catalog to page 14O Screw-in depth max. 8 For thread-forming screws according to DIN 7500 Electrical connection Connection cable Color brown (bn) light blue (lbu) black (bk) Function Phase Neutral conductor Auxiliary phase Cable length 180 ± 20 from motor Cable end 6 ± 2 with ferrules Change of the rotating direction is possible by polarity reversal of the wires bk bn For motor-gearbox combinations, depending on the choice of the single components, the maximum allowable torque (gearbox) can be exceeded or respectively not reached.
Open the catalog to page 15- Clockwise directional rotation (see connection diagram) - Symmetrical winding, also suitable for counter-clockwise rotation - Continuous operation S1 - Ball bearing - Insulation class F (VDE/EN) Characteristic curve
Open the catalog to page 16O Screw-in depth max. 8 For thread-forming screws according to DIN 7500 Electrical connection Color brown (bn) light blue (lbu) black (bk) Function Phase Neutral conductor Auxiliary phase Cable length 180 ± 20 from motor Cable end 6 ± 2 with ferrules Change of the rotating direction is possible by polarity reversal of the wires For motor-gearbox combinations, depending on the choice of the single components, the maximum allowable torque (gearbox) can be exceeded or respectively not reached.
Open the catalog to page 17All Ebm-papst catalogs and technical brochures
-
EC centrifugal fans RadiCal
76 Pages
-
AC Motors
16 Pages
-
514 F
4 Pages
-
BCI
60 Pages
-
ECI Series
84 Pages
-
VHD146
5 Pages
-
It’s All a Matter of TechNiQ.
16 Pages
-
Centrifugal fans and blowers
616 Pages
-
Condensing boiler technology
48 Pages
-
AC motors
11 Pages
-
RadiPac EC centrifugal fans
136 Pages
-
RadiCal EC centrifugal fans
172 Pages
-
Axial fans (version 2007)
436 Pages
-
ECI motors
24 Pages
-
VDC-3-49.15
8 Pages
-
ECI 63 modular drive series
14 Pages
-
BG motors
5 Pages
-
BCI motors
28 Pages
-
AC axial fans - HyBlade®
48 Pages
-
EC axial fans - HyBlade®
48 Pages
-
AC / EC Transformer Fans
36 Pages
-
Compact fans for AC and DC
269 Pages
-
Accessories for fans
23 Pages
-
AC axial fans
26 Pages
-
ACmaxx fans
22 Pages
-
Specials for fans
18 Pages
-
DC centrifugal fans
72 Pages
-
DC axial fans
64 Pages
-
AC and DC voltage compact fans
268 Pages
-
RadiPac EC centrifugal fans
104 Pages
-
RadiCal EC/AC centrifugal fans
184 Pages
-
EC/AC axial fans - AxiCool
56 Pages
-
VarioDrive C
9 Pages
-
Plug fans with EC motor
76 Pages
-
GreenTech: The Green Company.
16 Pages
Archived catalogs
-
Condensing boiler technology
48 Pages