ISOjag insulation jacket
2Pages

{{requestButtons}}

Catalog excerpts

ISOjag insulation jacket - 1

ISOjag Venturi Orifice steam trap removable Insulation jackets The new EBE ISOjag Removable Insulation Jackets are designed to fit the ECOFLOW Venturi Orifice Steam Traps sizes ranging from DN15 to DN50. Cutting heat losses by a typical 90%, it is extremely easy to remove and replace, so that steam trap maintenance can be carried out quickly and efficiently, saving time and money. The value of insulating steam plant is well documented. All responsible and proactive steam users are aware of the tremendous energy savings possible through good insulation of pipework. Heat losses from uninsulated pipework* Exactly fits the Venturi Orifice Steam Traps sizes DN15 – DN50 Self-contained insulation system, independent from any pipework insulation Rugged Velcro fastener strips I.D. Tagging with part number,Nozzle sizing and location identification. Double sewn construction with bond edging Jackets are fabricated from DuPontTM Nomex® 455 (NOMEX III), a patented blend of NOMEX and KEVLAR brand fibers. The outer layer has a weight of 160gm/m2, with a silicone coated glass fibre cloth encapsulated in up to ten further Nomex insulation layers. Pullcords are Kevlar for maximum performance in high temperature environments ISOjag jackets are suitable for use on applications up to 200 degrees centigrade Convenient, ISOjag insulation jackets are extremely easy to remove and replace so that maintenance personal can easily and quickly inspect the steam traps High quality durable construction Is truly “REMOVABLE & REUSABLE” (remember...all insulation is removable) Guaranteed fit for Orifice Steam traps -90% reduction in heat losses -90% productivity gains in maintenance activity (assembly/disassembly) compared to the traditional solution Return on investment between 3 and 18 months (for non-insulated surface temperatures between 200°C and 60°C respectively). Can help you meet health and safety requirements by keeping the workplace safer *Losses per meter of bare pipe For example the losses from bare steam pipes at 140 degC differential temperature, range from 184 W/m for a 15mm N.B. pipe, to over 800 W/m for 100mm N.B. pipes. Insulation typically cuts the heat losses by 90% of the values stated above. Savings in fuel typically pay for the cost of insulating within a year. In addition insulating pipework will reduce discomfort from overheating in summer and hot, bare steam and condensate pipes are also a health and safety hazard to personnel. EBE Engineering GmbH, Rellinghauser Straße 334F, 45136 Essen

Open the catalog to page 1
ISOjag insulation jacket - 2

ISOjag Venturi Orifice steam trap removable Insulation jackets DIMENSIONS The advantages of an ISOjag insulation jacket Although insulation is widespread on industrial steam plant, steam traps and flanges are often overlooked during the insulation process. However, it is estimated that a single uninsulated steam trap has thermal radiation losses equal to one meter of straight pipework (based upon the nominal diameter of the steam trap). The ISOjag insulation jacket can reduce thermal radiation losses by up to 90%. It is designed for speed and ease of installation and can be retrofitted to...

Open the catalog to page 2

All EBE-Engineering GmbH catalogs and technical brochures