2GPe cVM e- drive - 1

Inverter controlled units with two vertical multi-stage pumps. TYPICAL APPLICATIONS GPE pressurisation units have the following applications: • Water supply or distribution networks, apartment blocks, schools, hotels, etc. • Generic industrial water supply • Irrigation for gardens, parks and sports facilities UNIT EQUIPMENT • Two CVM series pumps with 2-pole self-ventilating asynchronous motor, efficiency class IE2 for three-phase motors starting from 0.75 kW with E-drive series INVERTER • Control unit: pumps equipped with inverters for modulating control • INVERTER control of each pump with pressure transducer and electronic control display • Corrosion resistant materials for all components in contact with fluids • Galvanised steel base • Galvanised steel manifolds (AISI 304, AISI 316 available on request). The manifolds are dimensioned in relation to the total hydraulic output of the pressurisation system • Delivery side shut-off valve on each pump • Delivery side check valve • Protection against water supply failure as standard supply • Equipped for connection to delivery side accumulation tank Your Life, our Quality. Worldwide. INVERTER CONTROL UNIT E-drive is device for controlling and protecting pumping systems by varying the pump power voltage. E-drive can be connected to any commercially available pump, and is used to keep a given setting constant (pressure, flow rate, fluid temperature, etc.) as the operating conditions vary. This means that the pump runs only when needed, thus preventing energy wastage and increasing its service life. E-drive can also: • protect the motor from overloads and dry running • provide soft starts and stops to increase system life and reduce absorption peaks • provide information about current absorption and power voltage • register the hours of operation and trip alarms as required • run one or more pumps at constant speed (DOL: Direct On Line) • connect to other E-drives for combined operation • Voltage: - Version MT: - Power voltage: single-phase 230V - Output voltage (pump): three-phase 230V - Version TT: - Power voltage: three-phase 400V - Output voltage (pump): three-phase 400V • Mains power frequency: 50 - 60 Hz (+/- 2%) • Max. ambient operating temperature at nominal load: 40°C (104 °F) • Max. altitude at nominal load: 1000 m • Protection rating: IP55 (NEMA 4) • Digital outputs configurable as NO or NC: 1. motor run signal 2. alarm signal 3. pump command DOL 1 4. pump command DOL 2 • Analogue inputs (10 / 15 VDC): 1. 4-20 mA 2. 4-20 mA 3. 4-20 mA / 0 - 10 VDC (configurable) 4. 4-20 mA / 0 - 10 VDC (configurable) • 4 digital inputs, configurable NO or NC, for motor start/stop The contents of this publication must not be regarded as binding. EBARA Pumps Europe S.p.A. reserves the right to effect any modification it deems nece

Open the catalog to page 1
2GPe cVM e- drive - 2

2GPE CVM E-drive DOMESTIC PRESSURISATION TECHNICAL FEATURES APPLICATION RANGE • Maximum operating pressure: 11 bar • Max fluid temperature: 40°C • MEI > 0.4 For further information, refer to the Data Books available on www. ebaraeurope.com PUMP MATERIALS • Cast iron pump body and motor mount • AISI 304 external jacket • Impeller and diffuser in PPE + glass fibre reinforced PS • Stages in PPE + glass fibre reinforced PS/PTFE • AISI 416 shaft ADVANTAGES • Energy saving: the controller modulates the pump rate in relation to system demand, better than direct in-line connection to the mains...

Open the catalog to page 2
2GPe cVM e- drive - 3

2GPE CVM E-drive DOMESTIC PRESSURISATION PERFORMANCE CURVES for 2GPE CVM B 15 series (ISO 9906 Annex A) PERFORMANCE CURVES for 2GP CVM A 10 - A 12 - A 15 series PERFORMANCE CURVES for 2GPE CVM B 20 B 23 series The indicated characteristics do not include the pressure drops in the valves and lines The indicated NPSH is a laboratory value related to the pump alone Your Life, our Quality. Worldwide. The contents of this publication must not be regarded as binding. EBARA Pumps Europe S.p.A. reserves the right to effect any modification it deems necessary, without prior notice.

Open the catalog to page 3
2GPe cVM e- drive - 4

2GPE CVM E-drive DOMESTIC PRESSURISATION TABLE OF PERFORMANCE AND ELECTRICAL DATA FOR TWO PUMPS RUNNING SIMULTANEOUSLY Model MT 2GPE CVM A/10 E-DRIVE 1500 MT 2GPE CVM A/12 E-DRIVE 1500 MT 2GPE CVM A/15 E-DRIVE 1500 MT 2GPE CVM B/15 E-DRIVE 1500 MT 2GPE CVM B/20 E-DRIVE 1500 MT - The contents of this publication must not be regarded as binding. EBARA Pumps Europe S.p.A. reserves the right to effect any modification it deems necessary, without prior notice. DIMENSION CHART Model MT TT 2GPE CVM A/10 E-DRIVE 1500 MT 2GPE CVM A/1 0 E -DRIVE 2200 TT 2GPE CVM A/12 E-DRIVE 1500 MT 2GPE CVM A/12 E...

Open the catalog to page 4

All EBARA PUMPS EUROPE catalogs and technical brochures

  1. DW - DW VOX

    15 Pages

  2. DS-DVS

    3 Pages

  3. DML-DMLV

    5 Pages

  4. CDX-CDXL

    3 Pages

  5. Q series

    1 Pages

  6. e- poWer

    1 Pages

  7. DFFRP

    1 Pages

  8. D-TANK

    2 Pages

  9. 1epbh

    2 Pages

  10. idroGo

    4 Pages

  11. SF6

    18 Pages

  12. PRA-PRN

    4 Pages

  13. Q_SERIES

    1 Pages

  14. QA60C_SERIES

    1 Pages

  15. QM1_SERIES

    1 Pages

  16. QM2_SERIES

    1 Pages

  17. QME1_SERIES

    1 Pages

  18. QME2_SERIES

    1 Pages

  19. QS1_SERIES

    1 Pages

  20. QS2_SERIES

    1 Pages

  21. QS3_SERIES

    1 Pages

  22. QT1_SERIES

    1 Pages

  23. QT2_SERIES

    1 Pages

  24. QT3_SERIES

    1 Pages

  25. RIGHT

    3 Pages

  26. SANIRELEV

    5 Pages

  27. SB3

    3 Pages

  28. SP SERIES

    1 Pages

  29. SWS-SWT

    3 Pages

  30. WINNER 4N

    14 Pages

  31. pressCoMfort

    1 Pages

  32. CVM

    10 Pages

  33. 1GP P

    1 Pages

  34. 1GP H

    2 Pages

  35. 6BHE(L)

    26 Pages

  36. 4BHS

    5 Pages

  37. 3TP

    4 Pages

  38. 2CDX Surface

    5 Pages

  39. DL-DL W/C

    22 Pages

Archived catalogs