Catalog excerpts
F:T*MPowering Business Worldwide
Open the catalog to page 1Energizing a world that demands more. We deliver: • Electrical solutions that use less energy, improve power reliability and make the places we live and work safer and more comfortable Hydraulic and electrical solutions that enable machines to deliver more productivity without wasting power Aerospace solutions that make aircraft lighter, safer and less costly to operate, and help airports operate more efficiently Vehicle drivetrain and powertrain solutions that deliver more power to cars, trucks and buses, while reducing fuel consumption and emissions Discover today’s Eaton. Powering...
Open the catalog to page 2High frequency TL lighting is often used in agricultural industry applications (such as barns). Conventional circuit breakers appear to sometimes fail spontaneously, which is very undesirable in barns. Consider a failure of the ventilation systems, feeding systems, manure and egg collection in poultry barns. By using the new digital circuit breaker from Eaton, the problem of undesired switch off can be minimized. MCBs and RCCBs for North American market UL certified for eOEMs who acting worldwide providing power distribution systems for Power Plants in North America. High safety relevant...
Open the catalog to page 3Digital protection switches – the new era has begun. Better security with proactive communication! The digital RCCB from Eaton’s xEffect series are capable to do more than just switch off: They monitor electrical installations and issue advance warnings of critical current flows. Thanks to short time delay and optimized tripping threshold, briefly occurring malfunctions do not induce the digital protection switch to shut down. When a fault current crops up, the information is reported to the security center of the industrial plant right away and troubleshooting can start before a plant...
Open the catalog to page 4Highly qualified controllers offer their services PROMOTION Allow us to introduce ourselves: FRCdM and FRBdM would like to work in your switchbox. We‘re two highly qualified control robots from the famous EATON talent factory – the first of the new digital generation. It’s not only that I work completely reliably as a Residual Current Operated Circuit Breaker with integrated Overcurrent Protection (RCBO), but I also display the cause and extent of the flowing fault current. This enables fast actions quickly take measures to maintain system availability. The LEDs set off an alarm when fault...
Open the catalog to page 5FRBdM and FRCdM offer several other advantages The LED allows for a fault current display directly on site. In the service mode, malfunction causes can be determined quickly and without complication. The digital display facilitates real-time diagnostics directly at the switch. By means of the LEDs, the system status can be seen at anytime, and with one glance. All models have at least a short time delay to prevent from nuisance tripping due to transient disruptions (lightning, engine start). Digital Combi-switch FRBdM: With help of the service mode, the exact extent of the leakage current...
Open the catalog to page 6Benefits: • Reliable protection for machines with 1-phase frequency converters • Increased protection due to - detection of mixed frequencies - higher load rating with DC residual currents up to 10mA • Reduction of nuisance tripping thanks to - time delayed tripping - high current withstand capability The Type F RCD is defined according IEC/ EN 62423. It provides safe and reliable protection against sinusoidal residual currents and pulsating DC fault currents (like Type A devices). It is also capable of handling residual currents with mixed frequencies of up to 1 kHz (10, 50, 1000 Hz) in...
Open the catalog to page 7RCCB Type B (acc. IEC 62423) Standard type, sensitive to all residual currents according up to 1 kHz RCD Type F (acc. IEC 62423) Standard type, multi-frequency residual currents up to 1 kHz PV Systems Battery banks UPS Units EV charging Medical devices … Washing machines, dishwashers Heat pumps Motor applications Ventilation, cooling and air condition systems • Welding equipment • … • Appliances and motors with 1phase frequency converters (supply: phase/neutral) RCCB Type Bfq (acc. IEC62423) Non-sensitive against system caused earth leakage currents at high frequencies up to 50 kHz • 3...
Open the catalog to page 8Lean connectivity for protective devices (MCBs, RCCBs, RCBOs) - Permanent information of the system - Decrease system downtime/Increase system uptime - Direct connection to the SmartWire-DT line - Reduction of installation time, wiring and costs The SmartWire-DT MCB module allows a fast and easy connection of protective devices as MCBs, RCCBs and RCBOs to the SmartWire-DT line. This gives machinery builders and installers the possibility to integrate protective devices comfortable in the Lean automation. The status (on, off, tripped) of the protective devices is so implement in the control...
Open the catalog to page 9Description type designation RCD's … xEffect … RCCB … RCBO … RCD add on Block up to 63A … RCD add on Block up to 125A … mechanical … digital … electronic, voltage dependent … breaking capacity 10kA … breaking capacity >10kA … breaking capacity variable Description type designation MCB‘s FAZ … MCBs up to 63A FAZT … MCBS up to 40A with braking capacity >10kA AZ … MCBs up to 125A General definitions RCD RCCB RCBO MCB Residual Current operated Device (umbrella term for RCCB and RCBO) Residual Current Circuit Breaker Residual Current Operated Circuit Breaker with Overcurrent
Open the catalog to page 10Protective Devices Table of Contents Protective Devices 1. General • Switch Gear Digital. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1.3 2. Components • RCCB – RCCB FRCdM Type A, U and R, Digital . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1.7 – RCCB FRCdM Type B, Bfq and B+, Digital . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Open the catalog to page 11All Eaton catalogs and technical brochures
-
Green Switching
4 Pages
-
EM20 Modbus Communication
18 Pages
-
Xiria Product Family
4 Pages
-
Power Xpert XP2 Aluminium
20 Pages
-
Power Xpert XP2 Copper
20 Pages
-
Industrial switch-disconnectors
148 Pages
-
Product Range Catalog SmartWire-DT®
108 Pages
-
xEnergy Basic
176 Pages
-
xEnergy Light
140 Pages
-
Data Networks
94 Pages
-
Arc Fault Protection ARCON
12 Pages
-
Panel Building Accessories
104 Pages
-
SASY 60i Busbar System
82 Pages
-
xComfort Compact Distributor Boxes
138 Pages
-
Industrial wireless products
4 Pages
-
SmartWire-DT Catalog
108 Pages
-
Product Launch
3 Pages
-
Ex-Safety and main current switches
100 Pages
-
Cable glands
34 Pages
-
Ex-Control and distribution systems
130 Pages
-
Crouse hinds
272 Pages
-
The safety you rely on
635 Pages
-
Protective Devices
358 Pages
-
Cam Switches T
256 Pages
-
Add-On Distribution Board XVTL
86 Pages
-
FMX Smart, Innovative Design
20 Pages
Archived catalogs
-
Product Overview for Machinery_2016
316 Pages
-
New Items Catalogue
38 Pages
-
MiniTrainer for Automation
23 Pages