video corpo

SASY 60i Busbar System
82Pages

{{requestButtons}}

Catalog excerpts

SASY 60i Busbar System - 1

Eaton - xEffect SASY 60i SASY 60i busbar system provides highest efficiency in the control panel

Open the catalog to page 1
SASY 60i Busbar System - 2

Energizing a world that demands more. We deliver: • Electrical solutions that use less energy, improve power reliability and make the places we live and work safer and more comfortable Hydraulic and electrical solutions that enable machines to deliver more productivity without wasting power Aerospace solutions that make aircraft lighter, safer and less costly to operate, and help airports operate more efficiently Vehicle drivetrain and powertrain solutions that deliver more power to cars, trucks and buses, while reducing fuel consumption and emissions Discover today’s Eaton. Powering...

Open the catalog to page 2
SASY 60i Busbar System - 3

Customer-focused and Innovative SASY 60i now a UL-certified Component SASY 60i - safe and reliable: In combination with the new generation of Eaton’s motor protectors and circuit breakers, SASY 60i provides a universal UL -certified solution for switching, protecting and distributing power. The modular SASY 60i busbar system by Eaton has been conceived for the efficient distribution of power in the switching cabinet. Thanks to busbar adapters, feed and output switches can be mounted directly onto the busbar system in a quick and a space-saving way. Optimized busbar profile The system offers...

Open the catalog to page 3
SASY 60i Busbar System - 4

Sammelschienen-System SASY 60i für den Weltmarkt Short installation time thanks to pre-assembly Eaton offers direct and reversing starters up to 15 kW, fully mounted on busbar adapters. These fully assembled units consist of one PKZM0 motor protector and one or two DILM contactor(s). In order to mount these, they only need to be clicked in place on the busbar; this guarantees reduced assembly times and costs. Special features of the device adapters The device adapters offer a special functionality in that they can be mounted onto different profiles and busbar thicknesses. The adapters...

Open the catalog to page 4
SASY 60i Busbar System - 5

A system designed for worldwide use Together with its system components, the SASY 60i busbar system is designed for worldwide use in control cabinets for mechanical and system engineering. Its design has even taken into account the greater clearance and creepage distances that must be observed in the U.S. pursuant to UL 508A. For busbar applications that have not been type-tested, UL508A allows an ampacity of 1000A/inch2 (1.55A/mm2). This value may be higher if the product or the application has been tested accordingly. Eaton has conducted extensive tests for the user’s maximum benefit in...

Open the catalog to page 5
SASY 60i Busbar System - 6

System up to 630 A for flat busbars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page xx System up to 1250, 1600 A for profile busbars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page xx Covers for 630, 1250 and 1600 A systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page xx Feeder circuit adapters for 630, 1250 and 1600 A systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page xx Terminals for 630, 1250 and 1600 A...

Open the catalog to page 6
SASY 60i Busbar System - 7

SASY 60i Busbar System SASY 60i Busbar System • Selected components are also conforming with UL-standards for control systems • 60 mm spacing between busbars • 630, 1250 and 1600 A rated current • Adapter technology for Switch Disconnectors • Adapter technology for Motor Starters • Slide fuse equipment • Connection technique

Open the catalog to page 7
SASY 60i Busbar System - 8

Poles Max. Special Features Utilisation Rated Operational Current Number Ie (A) Type Article No. Notes Units Designation per Busbar Support • Thermoplasticic, silicone-free, chlorine-free • Halogen-free • Self-extinguishing according to UL 94 • RAL 7035 • Track resistance CTI 200 • Temperature-resistant up to 120°C With snap-in slide 12 x 5/10 for adapting 15 x 5/10 drilled holes inside for screw-fixing With snap-in slide 12 x 5/10 for adapting 15 x 5/10 drilled holes inside for screw-fixing With snap-in slide 12 x 5/10 for adapting 20 x 5/10 BBS-3/FL-NA 107067...

Open the catalog to page 8
SASY 60i Busbar System - 9

Poles Max. Special Features Utilisation Rated Operational Current Number Ie (A) Type Article No. Notes Units Designation per UL Base Plate • Silicone-free, chlorine-free • Self-extinguishing according to UL 94 • Temperature-resistant up to 110°C wa_vH3713 -- - To be used when Necessary BBC-BT-NA 107172 1 100 mm 2 the air gap between for UL support long busbar systems and mounting plate is insufficient Busbar Covers • Silicone-free, chlorine-free • Self-extinguishing according to UL 94 • Temperature-resistant up to...

Open the catalog to page 9
SASY 60i Busbar System - 10

Poles Max. Special Features Utilisation Rated Operational Current Number Ie (A) Type Article No. Notes Units Designation per Busbar Support • Thermoplastic, silicone-free, chlorine-free • Halogen-free • Self-extinguishing according to UL 94 • RAL 7035 • Track resistance CTI 200 • Temperature-resistant up to 120°C Busbar Support Double-T-Profile 3 1600 Suitable as Double-T-Profile BBS-3/PR 107162 With pre-drilled 3 lateral and central holes inside support for screw Suitable for setting up a PE or N bar Double-T-Profile BBS-1/PR 107165 With...

Open the catalog to page 10
SASY 60i Busbar System - 11

Poles Max. Special Features Utilisation Rated Operational Current Number Ie (A) Type Article No. Notes Units Designation per Busbar Covers • Silicone-free, chlorine-free • Self-extinguishing according to UL 94 • Temperature-resistant up to 110°C For BBC-CU-BAR/PR 107175 1000 mm 5 Double-T-Profile long of 87.5°C and an ambient temperature of 35°C, please refer to the current load diagram in the Technical Data section for further values.

Open the catalog to page 11
SASY 60i Busbar System - 12

Type Article No. Notes Units Designation per Suits any thickness of bars if i BBC-MRCOV1 107179 To be used 10 with spare section cover BBC-RCOV1 only Single covers Compartment Section Double-T wa_"t12913 For 3-pole systems with BBS-3/PR BBC-CS48/PR 107176 48 mm high 1 2400 mm long To be fixed at the (profile) bar support For 3-pole systems with BBS-3/PR BBC-CS76/PR 107177 76 mm high 1 2400 mm long To be fixed at the (profile) bar support Cover module for cut-out. Height = 195 mm

Open the catalog to page 12

All Eaton catalogs and technical brochures

  1. xEnergy Basic

    176 Pages

  2. xEnergy Light

    140 Pages

  3. Data Networks

    94 Pages

  4. Cable glands

    34 Pages

  5. Crouse hinds

    272 Pages

  6. Cam Switches T

    256 Pages

Archived catalogs