ESR5 safety relay Control relay suitable for safety applications easySafety
18Pages

{{requestButtons}}

Catalog excerpts

ESR5 safety relay Control relay suitable for safety applications easySafety - 1

ESR5 safety relay Control relay suitable for safety applications eaySafety The safety of humans and machinery must be guaranteed throughout the entire life cycle of the machinery or installation. Safety-related components for functional safety, such as position switches, light barriers, two-hand operation, or emergency stop pushbuttons provide personnel protection. Safety-related logic units monitor and evaluate safetyrelevant information. Safety relays from the series ESR5 and the safety-related control relay eaySafety fulfill the highest requirements of international safety norms. eaySafety control relays – Flexible, safety-related information processing All-in-One: Safety and control functions combined in one device +++ Simple configuration through prefabricated and tested safety components +++ Direct state display and increased machine availability due to fast error diagnosis through integrated display +++ Multistep password concept prevents unwanted manipulation 1 2 3. . ESR5 safety relays – profitable monitoring The right safety function for each application +++ Fast commissioning and error-free exchange through plug-in screw terminals +++ Multivoltage variants 24 – 230 V AC/DC for universal application

Open the catalog to page 1
ESR5 safety relay Control relay suitable for safety applications easySafety - 2

Safety relays Safety relay, control relay suitable for safety circuits System overview Safety relays 13/2 Description Safety relays 13/4 Ordering ES4P basic devices 13/5 Expansion Devices I/O expansions 13/6 Accessories Remote text display 13/7 Network connection cables 13/9 Switched-mode power supply units 13/9 PROFIBUS-DP data cable 13/10 PROFIBUS-DP bus connector plug 13/10 Top-hat rail adapter for inspection window 13/10 electronic safety relay Description Electronic safety relays Ordering ESR5 basic devices Contact expansion modules Technical data Basic devices, contact expansion...

Open the catalog to page 2
ESR5 safety relay Control relay suitable for safety applications easySafety - 3

Safety relays System overview Safety

Open the catalog to page 3
ESR5 safety relay Control relay suitable for safety applications easySafety - 4

Safety relays 13/3 Basic device Expandable: standard inputs/outputs and standard bus systems Bus system easyNet on board 24 V DC 14 safe digital inputs 4 safe relay outputs or 1 safe redundant relay output and 4 safe transistor outputs Display and keypad optional Bolt-on and top-hat rail mounting Screw terminals ^ Page 13/5 PROFIBUS DP slave interface, 24 V DC 24 V DC 12 digital inputs 6 relay outputs (max. 10 A, UL) or 8 transistor outputs Bolt-on and top-hat rail mounting Screw terminals ^ Page 13/6 CANopen interface, 24 V DC ^ Page 13/6 Remote text display 2 Consists of: •...

Open the catalog to page 4
ESR5 safety relay Control relay suitable for safety applications easySafety - 5

13/4 Safety relaysDescription The easySafety control relay for safety-related applications monitors all commonly used safety devices and also takes over the required control tasks for the machine. Packed with a host of conventional safety relays in the form of safety function blocks, easySafety not only features integrated safety functions but also standard functions in a single device - all in one. In addition to the safety circuit diagram containing the safety configuration, the safety control relay also contains a standard circuit diagram. This circuit diagram can be used for standard...

Open the catalog to page 5
ESR5 safety relay Control relay suitable for safety applications easySafety - 6

Safety relays Basic devices 13/5 Inputs (safety) Outputs (safety) Display + easyNet/ Safety/stan- Part no. Price Std. pack keypad easyLink dard circuit Article no. See price diagram list Digital 6 A relay Transistor Test signal easySafety EN 954-1: 1996, category 4 EN ISO 13849-1: 2006, PL e (Performance Level) IEC 61508: 1998, SIL 3 (Safety integrity Level) IEC 62061: 2005, SILCL 3 (Safety integrity level claim limit) Expandable: standard inputs/outputs and standard bus systems 24 V DC supply voltage Safety Technology Control the unexpected Notes Accessories Page 1 Power supply...

Open the catalog to page 6
ESR5 safety relay Control relay suitable for safety applications easySafety - 7

Expansion devices Inputs Outputs Supply Part no. Price Std. pack Information relevant for export to voltage Article no. See price North America Digital Relay Transis- i I-11-1 Product Standards UL File No. UL CCN CSA File No. CSA Class No. IEC/EN see Technical Data; UL 508; CSA C22.2 No. 142-M1987; CSA C22.2 No. 213-M1987; CE marking E135462 NRAQ, NRAQ7 012528 2252-01 + 2258-02 NA Certification UL Listed, CSA certified Degree of Protection IEC: IP20, UL/CSA Type: - Product Standards UL File No. UL CCN CSA File No. CSA Class No. IEC/EN see Technical Data; UL 508; CSA C22.2 No. 142-M1987; CSA...

Open the catalog to page 7
ESR5 safety relay Control relay suitable for safety applications easySafety - 8

Safety relays 13/7Accessories Supply Description Part no. Price Std. pack Information relevant for export to See price North America Remote text display Display/keypad monochrome display 132 x 64 pixels with switchable backlight IP65, removable silver front frame With keypad, with Moeller company logotype MFD-80-B NEMA 4x in connection with MFD-XM-80 265251 protective membrane ^ Page 12/29 With keypad, without Moeller company logotype MFD-80-B-X NEMA 4x in connection with MFD-XM-80 284905 protective membrane ^ Page 12/29 Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA...

Open the catalog to page 8
ESR5 safety relay Control relay suitable for safety applications easySafety - 9

13/8 Safety relaysAccessories Description Programming cables SUB-D, 9 pole, serial, 2 m Modem cable Configurable modem, printer and EASY800-MO-CAB 1 off possible data transfer rate 56 kBaud, 9 pole SUB-D plug (plug + socket for self connection) Product Standards UL File No. UL CCN CSA File No. CSA Class No. IEC/EN see Technical Data; UL 508; CSA C22.2 No. 142-M1987; CSA C22.2 No. 213-M1987; CE marking E135462 NRAQ 012528 2252-01 + 2258-02 NA Certification UL Listed, CSA certified Degree of Protection IEC: IP20, UL/CSA Type: - Memory card Manual Italian

Open the catalog to page 9
ESR5 safety relay Control relay suitable for safety applications easySafety - 10

Safety relays 13/9Accessories Description For use with Part no. Price Std. pack Information relevant for export to North America Network connection cables Length: 0.3 m Product Standards Bus termination resistor 8 pole, RJ45, 124 D Connectionto PIN 1 and PIN 2 easyNet EASY-NT-R UL File No. UL CCN CSA File No. CSA Class No. NA Certification Degree of Protection IEC/EN see Technical Data; UL 508; CSA C22.2 No. 142-M1987; CSA C22.2 No. 213-M1987; CE marking E135462 NRAQ 012528 2258-02 UL Listed, CSA certified IEC: IP20, UL/CSA Type: - Data cable easyNet EASY-NT-CAB Degree of Protection IEC: IP...