video corpo

ESR5 safety relay Control relay suitable for safety applications easySafety
18Pages

{{requestButtons}}

Catalog excerpts

ESR5 safety relay Control relay suitable for safety applications easySafety - 1

ESR5 safety relay Control relay suitable for safety applications eaySafety The safety of humans and machinery must be guaranteed throughout the entire life cycle of the machinery or installation. Safety-related components for functional safety, such as position switches, light barriers, two-hand operation, or emergency stop pushbuttons provide personnel protection. Safety-related logic units monitor and evaluate safetyrelevant information. Safety relays from the series ESR5 and the safety-related control relay eaySafety fulfill the highest requirements of international safety norms. eaySafety control relays – Flexible, safety-related information processing All-in-One: Safety and control functions combined in one device +++ Simple configuration through prefabricated and tested safety components +++ Direct state display and increased machine availability due to fast error diagnosis through integrated display +++ Multistep password concept prevents unwanted manipulation 1 2 3. . ESR5 safety relays – profitable monitoring The right safety function for each application +++ Fast commissioning and error-free exchange through plug-in screw terminals +++ Multivoltage variants 24 – 230 V AC/DC for universal application

Open the catalog to page 1
ESR5 safety relay Control relay suitable for safety applications easySafety - 2

Safety relays Safety relay, control relay suitable for safety circuits System overview Safety relays 13/2 Description Safety relays 13/4 Ordering ES4P basic devices 13/5 Expansion Devices I/O expansions 13/6 Accessories Remote text display 13/7 Network connection cables 13/9 Switched-mode power supply units 13/9 PROFIBUS-DP data cable 13/10 PROFIBUS-DP bus connector plug 13/10 Top-hat rail adapter for inspection window 13/10 electronic safety relay Description Electronic safety relays Ordering ESR5 basic devices Contact expansion modules Technical data Basic devices, contact expansion...

Open the catalog to page 2
ESR5 safety relay Control relay suitable for safety applications easySafety - 3

Safety relays System overview Safety

Open the catalog to page 3
ESR5 safety relay Control relay suitable for safety applications easySafety - 4

Safety relays 13/3 Basic device Expandable: standard inputs/outputs and standard bus systems Bus system easyNet on board 24 V DC 14 safe digital inputs 4 safe relay outputs or 1 safe redundant relay output and 4 safe transistor outputs Display and keypad optional Bolt-on and top-hat rail mounting Screw terminals ^ Page 13/5 PROFIBUS DP slave interface, 24 V DC 24 V DC 12 digital inputs 6 relay outputs (max. 10 A, UL) or 8 transistor outputs Bolt-on and top-hat rail mounting Screw terminals ^ Page 13/6 CANopen interface, 24 V DC ^ Page 13/6 Remote text display 2 Consists of: •...

Open the catalog to page 4
ESR5 safety relay Control relay suitable for safety applications easySafety - 5

13/4 Safety relaysDescription The easySafety control relay for safety-related applications monitors all commonly used safety devices and also takes over the required control tasks for the machine. Packed with a host of conventional safety relays in the form of safety function blocks, easySafety not only features integrated safety functions but also standard functions in a single device - all in one. In addition to the safety circuit diagram containing the safety configuration, the safety control relay also contains a standard circuit diagram. This circuit diagram can be used for standard...

Open the catalog to page 5
ESR5 safety relay Control relay suitable for safety applications easySafety - 6

Safety relays Basic devices 13/5 Inputs (safety) Outputs (safety) Display + easyNet/ Safety/stan- Part no. Price Std. pack keypad easyLink dard circuit Article no. See price diagram list Digital 6 A relay Transistor Test signal easySafety EN 954-1: 1996, category 4 EN ISO 13849-1: 2006, PL e (Performance Level) IEC 61508: 1998, SIL 3 (Safety integrity Level) IEC 62061: 2005, SILCL 3 (Safety integrity level claim limit) Expandable: standard inputs/outputs and standard bus systems 24 V DC supply voltage Safety Technology Control the unexpected Notes Accessories Page 1 Power supply...

Open the catalog to page 6
ESR5 safety relay Control relay suitable for safety applications easySafety - 7

Expansion devices Inputs Outputs Supply Part no. Price Std. pack Information relevant for export to voltage Article no. See price North America Digital Relay Transis- i I-11-1 Product Standards UL File No. UL CCN CSA File No. CSA Class No. IEC/EN see Technical Data; UL 508; CSA C22.2 No. 142-M1987; CSA C22.2 No. 213-M1987; CE marking E135462 NRAQ, NRAQ7 012528 2252-01 + 2258-02 NA Certification UL Listed, CSA certified Degree of Protection IEC: IP20, UL/CSA Type: - Product Standards UL File No. UL CCN CSA File No. CSA Class No. IEC/EN see Technical Data; UL 508; CSA C22.2 No. 142-M1987; CSA...

Open the catalog to page 7
ESR5 safety relay Control relay suitable for safety applications easySafety - 8

Safety relays 13/7Accessories Supply Description Part no. Price Std. pack Information relevant for export to See price North America Remote text display Display/keypad monochrome display 132 x 64 pixels with switchable backlight IP65, removable silver front frame With keypad, with Moeller company logotype MFD-80-B NEMA 4x in connection with MFD-XM-80 265251 protective membrane ^ Page 12/29 With keypad, without Moeller company logotype MFD-80-B-X NEMA 4x in connection with MFD-XM-80 284905 protective membrane ^ Page 12/29 Product Standards UL File No. UL CCN CSA File No. CSA Class No. NA...

Open the catalog to page 8
ESR5 safety relay Control relay suitable for safety applications easySafety - 9

13/8 Safety relaysAccessories Description Programming cables SUB-D, 9 pole, serial, 2 m Modem cable Configurable modem, printer and EASY800-MO-CAB 1 off possible data transfer rate 56 kBaud, 9 pole SUB-D plug (plug + socket for self connection) Product Standards UL File No. UL CCN CSA File No. CSA Class No. IEC/EN see Technical Data; UL 508; CSA C22.2 No. 142-M1987; CSA C22.2 No. 213-M1987; CE marking E135462 NRAQ 012528 2252-01 + 2258-02 NA Certification UL Listed, CSA certified Degree of Protection IEC: IP20, UL/CSA Type: - Memory card Manual Italian

Open the catalog to page 9
ESR5 safety relay Control relay suitable for safety applications easySafety - 10

Safety relays 13/9Accessories Description For use with Part no. Price Std. pack Information relevant for export to North America Network connection cables Length: 0.3 m Product Standards Bus termination resistor 8 pole, RJ45, 124 D Connectionto PIN 1 and PIN 2 easyNet EASY-NT-R UL File No. UL CCN CSA File No. CSA Class No. NA Certification Degree of Protection IEC/EN see Technical Data; UL 508; CSA C22.2 No. 142-M1987; CSA C22.2 No. 213-M1987; CE marking E135462 NRAQ 012528 2258-02 UL Listed, CSA certified IEC: IP20, UL/CSA Type: - Data cable easyNet EASY-NT-CAB Degree of Protection IEC: IP...

Open the catalog to page 10

All Eaton catalogs and technical brochures

  1. xEnergy Basic

    176 Pages

  2. xEnergy Light

    140 Pages

  3. Data Networks

    94 Pages

  4. Cable glands

    34 Pages

  5. Crouse hinds

    272 Pages

  6. Cam Switches T

    256 Pages

Archived catalogs