Eaton - Enclosures for all applications Eaton Diagnose System Temperature monitoring brings enhanced security to your switchboard N 4 ’’ Powering Business Worldwide
Open the catalog to page 1Busbar Temp Sensors Sensor 1 Extend Cat 5/ er over 5e cablin /6 g 198 fee • Permanent monitoring • Detection at an early stage Wireless PT1000 Temp Sensors Sensor 1 Managed Ethernet Switch • Diagnostics • Documentation Optional Wireless Router • Availability of the system • Wireless – no wiring of the sensors • Quick and easy installation • No batteries in the sensors • Permanent status transmission • Log-file recording • Integration into existing SCADA systems
Open the catalog to page 2• Incl. USB receiver 868 MHz (CKOZ-00/14) for wireless detection of the ambient temperature Type Article No. Pack • Wireless measuring of the busbar temperature via sensors Type Article No. Pack Temperature Sensor Busbar Temperature • Incl. holding brackets for 10 mm flat copper Adapter Plate • Incl. screws and Allen key Type Article No. Pack Type Article No. Pack Holding Brackets Type Article No. Pack For 15 mm Cu material thickness For 20 mm Cu material thickness
Open the catalog to page 3Temperature input Ambient Temperature • RF module for capturing the ambient temperature • Incl. fixing bracket • For max. 2 temperature sensors Type Article No. Pack Temperature Sensor for Ambient Temperature • PT1000, attachment hole 4mm, cable length = 1m Type Article No. Pack • Incl. fixing bracket Type Article No. Pack Test device busbar sensors Type Article No. Pack
Open the catalog to page 4Type Article No. Pack Power supply for USB-HUB • Rated voltage Input: 100-240V AC, 50/60Hz • Rated voltage Output: 24V DC, (±3%) • Rated current: 1.25A Type Article No. Pack Power supply LCD monitor (HMI) for local visualization of the user interface • A robust 12-inch display for industrial environments • Can be built into the switchboard directly • Degree of protection IP65 (front panel) • Brightness: 600 cd/m2 • Resolution: 1024x768 (4:3) • Contrast ratio: 700:1 • Supply voltage: 9 - 36V DC • Operating temperature: -20°C bis +60°C • Capacitive 2-finger touch • Interfaces: 1x HDMI...
Open the catalog to page 5Ω Diagnose System Technical Data Introduction Eaton DIAGNOSE was developed to provide permanent monitoring of our low-voltage main distribution boards. This results in a wide variety of advantages such as early detection, warning messages, diagnostics, documentation, increased system availability, optimized service intervals, reduction of infra-red scans, reduction of mechanical strain, ... placed in areas of the system that are difficult or impossible to access for thermo-scans. As it is no longer necessary to remove covers or planks for thermo-scans, it also results in increased safety for...
Open the catalog to page 6Ω Diagnose System Technical Data Functional overview System description to a maximum permitted threshold limit, a pre-warning level will be triggered. This will be displayed in orange in the Diagnostics software. In the overview, the respective sensor will change its colour. If a temperature value exceeds the respective threshold limit, the sensor will turn red. If a sensor does not send any information (no current on the busbar), it will be indicated in yellow. DIAGNOSE is a wireless and maintenance-free temperature monitoring system for busbar systems and ambient temperatures. It can be...
Open the catalog to page 7Ω Diagnose System System overview Basic Configuration 1: Local connection to PC/laptop via static IP address, configuration and data readout via PC/laptop, no network connection required, max. 5 sections can be monitored with one USB receiver, additional monitoring of ambient air temperature as reference value. Since only one USB receiver is being used in this configuration, the size of the assembly is limited to 5 sections. The reason for this is the transmission power of the sensors, as the metal separations may interfere with the signal. (Proposal: Install the controller, including the USB...
Open the catalog to page 8Ω Diagnose System System overview Configuration 3: This is an extended version of configuration 2 - up to 4 USB receivers can be connected to the controller via so-called USB extensions, which allows for the monitoring of up to 20 sections. If the USB extension is to be used, the installation principle remains the same as in configuration 1 and 2. This means that receiver 1 - which collects the data from the sensors in section 1 through 5 - should be installed in section number 3. Receiver 2 should be placed in section 8 and is responsible for the sensors in sections 6 to 10, etc. The distance...
Open the catalog to page 9Ω Diagnose System Technical Data Detailed explanation of the individual components DIAGNOSE Controller: The heart of Eaton DIAGNOSE is the DIAGNOSE Controller. This is where the system configuration is uploaded to and saved. The threshold limit values for the different field/section configurations are already pre-configured at the factory before delivery. After DIAGNOSE has been started up, all the data/temperatures collected will be saved for one month. Following that period, the first data saved will be gathered at a time. Thanks to its large memory capacity, gathering data over the course of...
Open the catalog to page 10Ω Diagnose System Technical Data Detailed explanation of the individual components USB receiver 2.4 GHz The USB drive serves as the interface between the controller and the sensors in the respective section of the main busbar. The number of sensors per receiver is limited to 200. The USB stick can be connected to the controller directly or by using a USB extension. In general, no more than 5 sections should be monitored through one receiver, to ensure that the signal is sufficiently strong to transmit the measurements. Features: • 2.4 GHz signal • A maximum of 4 USB receivers can be...
Open the catalog to page 11For more information, visit Eaton.com. To contact an Eaton salesperson or local distributor/agent, please visit www.eaton.eu/electrical/customersupport Eaton Industries (Austria) GmbH Scheydgasse 42 1210 Vienna Austria Eaton EMEA Headquarters Route de la Longeraie 7 1110 Morges, Switzerland Eaton.eu © 2017 Eaton All Rights Reserved Publication number CA014007EN Printed in Austria September 2017 Grafics: SRA, Schrems Eaton is a registered trademark. All other trademarks are property of their respective owners. Follow us on social media to get the latest product and support information. Eaton...
Open the catalog to page 12All Eaton catalogs and technical brochures
-
Green Switching
4 Pages
-
EM20 Modbus Communication
18 Pages
-
Xiria Product Family
4 Pages
-
Power Xpert XP2 Aluminium
20 Pages
-
Power Xpert XP2 Copper
20 Pages
-
Industrial switch-disconnectors
148 Pages
-
Product Range Catalog SmartWire-DT®
108 Pages
-
xEnergy Basic
176 Pages
-
xEnergy Light
140 Pages
-
Data Networks
94 Pages
-
Arc Fault Protection ARCON
12 Pages
-
Panel Building Accessories
104 Pages
-
SASY 60i Busbar System
82 Pages
-
xComfort Compact Distributor Boxes
138 Pages
-
Industrial wireless products
4 Pages
-
SmartWire-DT Catalog
108 Pages
-
Product Launch
3 Pages
-
Ex-Safety and main current switches
100 Pages
-
Cable glands
34 Pages
-
Ex-Control and distribution systems
130 Pages
-
Crouse hinds
272 Pages
-
The safety you rely on
635 Pages
-
Protective Devices
358 Pages
-
Cam Switches T
256 Pages
-
Add-On Distribution Board XVTL
86 Pages
-
FMX Smart, Innovative Design
20 Pages
Archived catalogs
-
Product Overview for Machinery_2016
316 Pages
-
New Items Catalogue
38 Pages
-
MiniTrainer for Automation
23 Pages