video corpo

Accessories for RCDs, MCBs, Combined RCD/MCB Devices, Motor Starters and Power Limiters
12Pages

{{requestButtons}}

Catalog excerpts

Accessories for RCDs, MCBs, Combined RCD/MCB Devices, Motor Starters and Power Limiters - 1

Accessories for Protective Devices Accessories for RCDs, MCBs, Combined RCD/MCB Devices, Motor Starters and Power Limiters – Auxiliary Switch – RCD-Tripping Module – Shunt Trip Release – Undervoltage Release – Remote Control and Automatic Switching Device – Switching Interlocks

Open the catalog to page 1
Accessories for RCDs, MCBs, Combined RCD/MCB Devices, Motor Starters and Power Limiters - 2

Accessories for Protective Devices Auxiliary Switch Z-HK, Z-AHK, Z-HD; Tripping Signal Switch Z-NHK Design: for screwing For Protective Device / Function Type Designation PFIM, PFHM-4p, dRCM 1NO+1NC PLS., PKD., PFHM-2p1NO+1NC PLS., PKD., PFIM, PFHM dRCM 2CO PFDM 1CO+1NC Auxiliary Switch ZP-AHK, ZP-IHK, ZP-WHK; Tripping Signal Switch ZP-NHK Design: for snapping For Protective Device / Function Type Designation ZP-AHK ZP-IHK ZP-WHK ZP-NHK RCD-Tripping Module Z-.AM For Protective Device Type Designation PFIM, PFHM-4p, dRCM PKNM, PKDM, PFHM-2p Z-FAM Z-KAM Type Designation Shunt Trip Release...

Open the catalog to page 2
Accessories for RCDs, MCBs, Combined RCD/MCB Devices, Motor Starters and Power Limiters - 3

Accessories for Protective Devices Remote Control and Automatic Switching Device Z-FW Type Designation Automatic restarting 230VAC Z-FW-LP Automatic restarting 24-48VDC Z-FW-LPD + Remote control Z-FW-MO (only in connection with Z-FW-LP, -LPD from delivery Article No. Units per package • Set consisting of automatic switching device Z-FW-LP. and switching module Z-FW-MO Remote Testing Module Z-FW (for Z-FW-LR/MO set use only) Type Designation Switching interlock without lock IS/SPE-1TE for Isolators, RCDs, combined Article No. Units per package Switching interlock without lock Z-IS/SPE-1TE...

Open the catalog to page 3
Accessories for RCDs, MCBs, Combined RCD/MCB Devices, Motor Starters and Power Limiters - 4

Accessories for Protective Devices Auxiliary Switch Z-HK, Z-AHK; Tripping Signal Switch Z-NHK • Design according to IEC/EN 60947-5-1, IEC/EN 62019 Connection diagrams • Can be mounted subsequently (screws) Z-HK Z-AHK Z-NHK • The specified minimum voltages are per contact 13 21 Take into account particularly in case of series connection! • Z-AHK, Z-NHK: Contact function with relative movement (self-cleaning contacts) 22 14 • Contact material and design particularly suitable for extra low voltage • Z-NHK: The function of one of the two change-over contacts can be switched from “auxiliary...

Open the catalog to page 4
Accessories for RCDs, MCBs, Combined RCD/MCB Devices, Motor Starters and Power Limiters - 5

Accessories for Protective Devices Example: Z-HK+PFIM Powering Business Worldwide

Open the catalog to page 5
Accessories for RCDs, MCBs, Combined RCD/MCB Devices, Motor Starters and Power Limiters - 6

Accessories for Protective Devices Auxiliary Switch ZP-IHK, ZP-WHK; Tripping Signal Switch ZP-NHK • • • • • • • • Design according to IEC/EN 62019 Connection diagrams No screws required. Can be snapped onto PLS and PKNM subsequently ZP-IHK ZP-WHK ZP-NHK ZP-IHK, ZP-WHK: can be snapped on additionally 1 time onto itself The specified minimum voltages are per contact. Take into account particularly in case of series connection! Contact material and design particularly suitable for extra low voltage. Contact function with relative movement (self-cleaning contacts)e) ZP-NHK: The function of one...

Open the catalog to page 6
Accessories for RCDs, MCBs, Combined RCD/MCB Devices, Motor Starters and Power Limiters - 7

Accessories for Protective Devices RCD Tripping Module Z-FAM (PFIM, PFHM-4p), Z-KAM (PKNM, PKDM, PFHM-2p) • For remote switch-off of RCDs, standard and electronic combined RCD/MCB Connection devices Z-FAM • Remote switch-off by one or several parallel potential-free contacts, e.g. W1 K1 pushbutton max. rated current 3 A at 250 V, take into account maximum pushbutton voltage Ω • Remote tripping test by means of remote testing module Z-FW • Can be mounted subsequently, to be wired according to connection diaW2 K2 gram with the respective terminals of the RCD • Tripping module for PFIM 0.5A...

Open the catalog to page 7
Accessories for RCDs, MCBs, Combined RCD/MCB Devices, Motor Starters and Power Limiters - 8

Accessories for Protective Devices Shunt Trip Release Z-ASA, ZP-ASA • Remote release for subsequent mounting onto PLS, CLS6, • Additional installation of standard auxiliary switch is possible • Position indicator red - green • Type ZP-ASA for snap-on mounting Connection diagram Technical Data Can be mounted onto RCDs, combined RCD/MCBs: Operational voltage range Possible standard auxiliary switch Z-NHK Z-NHK ZP-NHK ZP-NHK Frame size Device height Device width Degree of protection, built-in Terminal protection Terminal capacity quick fastening with 2 lock-in positions on DIN rail IEC/EN...

Open the catalog to page 8
Accessories for RCDs, MCBs, Combined RCD/MCB Devices, Motor Starters and Power Limiters - 9

Accessories for Protective Devices Undervoltage Release Z-USA, Z-USD Instantaneous Z-USA • Voltage control indicator blue/white • Service key for zero voltage switch-on for testing purposes Connection diagram Technical Data Making threshold Tripping threshold Frame size Device height Device width Degree of protection, built-in Terminal capacity Terminal protection quick fastening on DIN rail IEC/EN 60715 open mouthed/lift open mouthed/lift finger and hand touch safe, according to BGV A3, OVE-EN 6 open mouthed/lift Connection Example Release Connection example Connection example Powering...

Open the catalog to page 9
Accessories for RCDs, MCBs, Combined RCD/MCB Devices, Motor Starters and Power Limiters - 10

Accessories for Protective Devices Remote Control and Automatic Switching Z-FW • Shape compatible switching device suitable for subsequent installation for automatic re-setting and remote control of CLS6, PFIM, PFHM-4p, dRCM, • Mechanical interlock, can be sealed with leads • Mechanical switching capability up to max. PFIM-100/4p, CLS6-100/4p • Operating and alarm display by green and red LED • Function extension with Switching Modul Z-FW-MO Operating and trouble display by LED pre-assembled only with Z-FW... Connection diagrams Z-FW-LP Z-FW-LPD Z-FW-MO Technical Data Possible operating...

Open the catalog to page 10
Accessories for RCDs, MCBs, Combined RCD/MCB Devices, Motor Starters and Power Limiters - 11

Accessories for Protective Devices Remote Testing Module Z-FW (for Z-FW-LP) • External testing module with testing resistor for RCDs • Proper "external" test key function according to the applicable rules thanks to design adapted to the rated tripping current • For remote testing with remote control and automatic switching device Z-FW-LP • No undesired voltage rise in the consumer system during remote switch-off thanks to integrated breaker contact K1-K2 • Can also be used as a remote tripping module for PFIM, PFHM Connection examples Connection diagram: Connection diagram: Powering...

Open the catalog to page 11
Accessories for RCDs, MCBs, Combined RCD/MCB Devices, Motor Starters and Power Limiters - 12

Accessories for Protective Devices Switching interlocks IS/SPE-1TE, Z-IS/SPE-1TE • Without lock Type IS/SPE-1TE: • for Isolators, RCDs, combined RCD/MCBs, ... Type Z-IS/SPE-1TE: • for MCBs and Circuit Breaker ZP-A

Open the catalog to page 12

All Eaton catalogs and technical brochures

  1. xEnergy Basic

    176 Pages

  2. xEnergy Light

    140 Pages

  3. Data Networks

    94 Pages

  4. Cable glands

    34 Pages

  5. Crouse hinds

    272 Pages

  6. Cam Switches T

    256 Pages

Archived catalogs