Catalog excerpts
Eaton Hydrokraft Open Loop Piston Pumps Powering Business Worldwide
Open the catalog to page 1Introduction Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Typical Section. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Model Codes Basic Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 . . DF Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 LR Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 SP Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Open the catalog to page 2Modular design gives these pumps a wide range of applications. Fast response times. Axial piston pumps with swash plate design for reliable operation and long life. Pressure up to 420 bar. Rated speed up to 1800 rev/ min. Higher speeds possible. Oversize shafts and bearings. Rotating and pressure-loaded parts are pressure balanced. Through-drive enables multiple pump installations from a single shaft. Multiple pump combinations are also available. Integrated pilot pump, filter and pressure relief valves available. DF - Pressure compensator controlled LR - Power control with pressure limiter...
Open the catalog to page 3• Preferred standard option • Other standard option g Special option on request X Not available Pump Size Pump Size
Open the catalog to page 4• Preferred standard option • Other standard option • Special option on request X Not available Model Code Open Loop Pumps W Series - DF Control 0>Exam£leforiCustomerAdjustmentS£eci^:at|ons^^^^^^^_^^^^^^^ Special Pressure Main Stage Pilot Valve Load Sense Ap Adjustment Pressure Control Pressure Control Note: Setting must be at least 30 bar. Special Max. Minimum Maximum Displ. Adjustment Displacement Displacement Note: Special pressure adjustments and/or maximum displaoment adjustments are the most common reasons for using this option. EATON Hydrokraft
Open the catalog to page 5• Preferred standard option • Other standard option g Special option on request X Not available ◊ ExamgleforCustomerAdjustment^gecification^^^^^^^^^^^^^^^^ Special Pressure Main Stage Pilot Valve Load Sense Ap AdjuStnient Pressure Control Pressure Control Note: Setting must be at least 30 bar. Special Max. Minimum Maximum Displ. Adjustment Displacement Displacement Note: Special pressure adjustments and/or maximum displaoment adjustments are the most common reasons for using this option.
Open the catalog to page 6• Preferred standard option • Other standard option • Special option on request X Not available Model Code Open Loop Pumps W Series - SP Control ^ = P, M, R or S mandatory (electrical yoke position indicator) Main Stage Pilot Valve Pressure Control Pressure Control Special Pressure Adjustment Standard setting (bar) 20 Max. setting (bar) 40 Note: Setting must be at least 30 bar. Special Max. Minimum Maximum Displ. Adjustment Displacement Displacement Standard 0 cm3/rev 100% Note: Special pressure adjustments and/or maximum displaoment adjustments are the most common reasons for using this...
Open the catalog to page 7Preferred standard option Other standard option Special option on request Not available W Series - ST Control ^3 = K mandatory (FKM with HP lubrication) 33 = L (electrical yoke position indicator) Model Code Open Loop Pumps Pump Size 1) Only for pos. 26 C, D, and E and 2) Only for pos.26 G and H Notes: 0jExam£leforcustomeradjustments£ecif|cat|onsA4^i5j9i^^^^_^^^_ Special pressure Main stage Pilot valve . adjustment pressure control pressure control a Note: Setting must be at least 3Qbar, Special max. Minimum Maximum Displ. Adjustment displacement displacement Note: Special pressure...
Open the catalog to page 8• Preferred standard option • Other standard option • Special option on request X Not available ◊ Exam£l£for£ustomerAdjustment££ecifjcatjon^^^^^^^^^^^^^^^_ Special Pressure Main Stage Pilot Valve Load Sense Ap Adjustment Pressure Control Pressure Control Note: Setting must be at least 30 bar. Special Max. Minimum Maximum Displ. Adjustment Displacement Displacement Note: Special pressure adjustments and/or maximum displaoment adjustments are the most common reasons for using this option.
Open the catalog to page 9• Preferred standard option • Other standard option g Special option on request X Not available Model Code Open Loop Pumps W Series - PQ Control ^ = P, M, R or S mandatory (electrical yoke position indicator) Pump Size Pump Size 130 180 250 360 500 750 241251 Control Type PQ - Proportional valve multifunctional •••••• control (PpQ controller) 26 Displacement Adjustment Options D - CETOP 3 proportional valve + OBE •••••• E - CETOP 5 proportional valve + OBE • • • • •_• 271281 Control Electronic 00 - Without electronics •••••• (to be ordered separately) [29 Yoke Displacement Zone A - No...
Open the catalog to page 10Model Code Open Loop Pumps W Series - ES Control Available to special order only • Preferred standard option • Other standard option • Special option on request X Not available Pump Size Venting Valve Control Voltage Not applicable_ Customer Adjustment Specification None (standard) Eaton assigned number as per data specified in table below ◊_ Special Features None Defined by Eaton Design Number 10-99 assigned by Eaton 0^xam£l£for£ustomerAdjustment££ecifjcatjon^^^^^^^^^^^^ Special Maximum Minimum MaximumDisplacement Adjustment Displacement Displacement Standard 0 cm3/rev 100% Note: Special...
Open the catalog to page 11• Preferred standard option • Other standard option g Special option on request X Not available Model Code Open Loop Pumps W Series - No control: 0 = F Fixed Displacement PFW Models EATON Hydrokraft W-Series Open Loop Piston Pumps V-PUPI-TM00
Open the catalog to page 12• Preferred standard option • Other standard option • Special option on request X Not available Model CodeCombination Pump UnitP 1 WC - ******************** individual Model Codes of each unit. • The first displacement represents the largest unit, and so on. • For each unit included in the combination, a separate Model Code should be compiled using the Form page at the beginning of the Model Codes section. • Characters [20 to [39] of the Combination Model Code will be part number of the combination, defined by Eaton and stated on the order acknowledgement. • Front and middle units must each...
Open the catalog to page 13All Eaton Hydraulics catalogs and technical brochures
-
Eaton STC® Connectors Catalog
48 Pages
-
Eaton VSQ Vane Pumps
28 Pages
-
EHST-3-40 Series
8 Pages
-
Power amplifier
60 Pages
-
Fluid Conveyance Master Catalog
196 Pages
-
KBH-05 10 Series
22 Pages
-
GD5-Series
24 Pages
-
Motion control valves
124 Pages
-
KBCG-6-1
16 Pages
-
KBCG-3-1*
16 Pages
-
LifeSense Master Catalog
58 Pages
-
Electronic Feedback Cylinders
48 Pages
-
TLC Slip Detect Control Panel
18 Pages
-
Success made simple
16 Pages
-
Coils
14 Pages
-
2 Speed axial piston motor
14 Pages
-
Hydraulics Portfolio Brochure
12 Pages
-
Eaton HP50
4 Pages
-
Eaton Easy Couple H201
2 Pages
-
Eaton Delta motor
4 Pages
-
Eaton Weatherhead Core
20 Pages
-
Eaton Food Processing
26 Pages
-
Eaton Aeroquip Core
16 Pages
-
Eaton Engineered Solutions
12 Pages
-
Eaton EC600 X-FLEX
2 Pages
-
Press control blocks
4 Pages
-
Eaton Brass Products Master Catalog
166 Pages
-
Eaton® Industrial Cylinders
12 Pages
-
Airflex® Water-Cooled Brakes
22 Pages
-
Airflex® DBB & DBA Brakes
12 Pages
-
DG4V-3 70 Design Segment D
10 Pages
-
DG3V-8 & DG5V-8 Segment J
30 Pages
-
DG3V-7 & DG5V-7 Segment I
16 Pages
-
DG3V-5 & DG5V-5 Segment H
16 Pages
-
DG3V-3, DG4VP-3 Segment F
10 Pages
-
DG5V-7 30 Design & DG3V-7 20
16 Pages
-
Eaton Floating Housing Brake
8 Pages
-
Track Drive Motor - 2-Speed
16 Pages
-
Hydraulic Remote Controls
26 Pages
-
CNG Hose Catalog
12 Pages
-
External Gear Pump – GD5 Series
24 Pages
-
Low Speed, High Torque Motors
294 Pages
-
BECODISC Stacked Disc Cartridges
20 Pages
-
X20 Series 220 - Pump Catalog
20 Pages
-
Eaton Winner LQA Program - EMEA
54 Pages
-
Eaton Aeroquip Master Catalog
384 Pages
-
Eaton Guardian Seal
4 Pages
-
Accumulators Master Catalog
30 Pages
-
Filters Master Catalog
156 Pages
-
Industrial Hose and Tubing
216 Pages
-
Eaton?s Pump and Motor Products
24 Pages
-
E-HOEV-MC001
68 Pages
-
E-HOEV
2 Pages
-
EH066
2 Pages
-
A-HC
8 Pages
-
509200
4 Pages
-
E-HOBV
2 Pages
-
A-HOAK
69 Pages
-
et3000
19 Pages
-
ttc
28 Pages
-
ETRLD
20 Pages
-
x505901
21 Pages
-
509400
8 Pages
-
v fifi
36 Pages
-
i730
8 Pages
-
C001
23 Pages
-
XQ5
20 Pages
-
E2
21 Pages
-
E1
19 Pages
-
1E
2 Pages
-
DP
12 Pages
-
DBA
4 Pages
Archived catalogs
-
Accumulators
30 Pages
-
GEAR PUMPS AND MOTORS
35 Pages
-
ETON MOBILE VALVES
8 Pages
-
Hydro-Line® N5 Series Cylinders
36 Pages