Catalog excerpts

KBCG-3-1* - 1

Proportional pressure relief valves F:T*N Powering Business Worldwide

Open the catalog to page 1
KBCG-3-1* - 2

Contents GENERAL DESCRIPTION FUNCTIONAL SYMBOL TYPICAL SECTION MODEL CODES OPERATING DATA PERFORMANCE DATA INSTALLATION DIMENSIONS ELECTRICAL INFORMATION Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Typical wiring connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 . . FURTHER INFORMATION This product has been designed and tested to meet specific standards outlined in the...

Open the catalog to page 2
KBCG-3-1* - 3

General description An electro-hydraulic proportional relief valve designed to regulate pressure in a hydraulic system in proportion to an applied electrical input. These open-loop, single-stage valves can be used for direct control of pressure in low flow systems, or for pilot control of larger pressure controls, and for such applications as pressurecontrolled pumps. Other models For proportional pressure relief valves with flow ratings up to 400 L/min (106 USgpm), see catalog V-VLPO-MC003-E (model types KBCG, sizes 6 and 8). Valve design ensures low hysteresis and good repeatability....

Open the catalog to page 3
KBCG-3-1* - 4

KB Proportional valve with integral Pressure relief on Ramp options 1 No ramp 2 Standard ramp (typically 65 ms) 3 Long ramp (typically 80 ms) Command/pressure characteristic Mounting G Subplate mounted Interface 3 ISO 4401, size 3 (NFPA D03) Electrical connection Build orientation Blank Right hand (standard) PC7 7 pin connector, without plug supplied PE7 7 pin connector, with plug supplied enable signal PR7 as PC7 but with pin 'C' used for enable signal Controlled pressure range At rated flow of 1 L/min (0.26 USgpm) 40 2-40 bar (29-580 psi) Design number, 1* series 11 Subject to change...

Open the catalog to page 4
KBCG-3-1* - 5

Standard test conditions are with antiwear hydraulic oil at 36 cSt (168 SUS) and 40°C (104°F) Maximum pressures: Port P: Operating See [6] in "Model Code” Port T: Operating 2 bar (29 psi). See "Back pressure at port T” under "Installation and start-up” Flow limits: Rated flow Maximum flow Coil or amplifier rating Command signal: Volts (see model code E] - 1) Input impedance Common mode voltage to pin B Current (see model code E] - 2) Input impedance Valve enable signal: Enable Disable Input impedance 7-pin plug connector 1 L/min (0.26 USgpm) 5 L/min (1.3 USgpm) 24V x 40W max. (22 to 36V...

Open the catalog to page 5
KBCG-3-1* - 6

6 EATON Proportional pressure relief valves V-VLPO-MC002-E1 September 2020

Open the catalog to page 6
KBCG-3-1* - 7

Performance data Pressure gain, Typical Typical pressure v. command signal response of KBCG-3-250 models Test conditions: Fluid = Antiwear hydraulic oil at 36 cSt (168 SUS) % Command signal Pressure override, Typical Test conditions: Fluid = Antiwear hydraulic oil at 36 cSt (168 SUS) Pressure override (Rise above valve cracking pressure) (At valve cracking pressure) 0 Rated flow; see 6 in "Model Code" EATON Proportional pressure relief valves V-VLPO-MC002-E1 September 2020

Open the catalog to page 7
KBCG-3-1* - 8

Installation dimensions To bleed air, loosen plug in end of core tube; re-tighten to 2,4 +/- 0,2 Nm (1.85 +/- 0.15 Ibf ft) after bleeding is complete. EATON Proportional pressure relief valves V-VLPO-MC002-E1 September 2020

Open the catalog to page 8
KBCG-3-1* - 9

Electrical information Block diagram 7-pin plug connections +24V Power 0V Enable Non-inverting Command signal Ramp Current monitor Solenoid drive ▲ In valves with PH7 or PR7 type electrical connection. Wiring Connections must be made via the 7-pin plug mounted on the amplifier. Recommended cable sizes are: Power cables For 24V supply: 0,75 mm2 (18 AWG) up to 20m (65 ft) 1,00 mm2 (16 AWG) up to 40m (130 ft) Screen (Shield) A suitable cable should have at least 6 cores with pairs of conductors individually screened and an overall screen. Cable outside diameter 8,0-10,5 mm (0.31- 0.41 inches)....

Open the catalog to page 9
KBCG-3-1* - 10

Typical wiring connections Voltage input (M1) Spool position monitor voltage (pin F) will be referenced to the KB valve local ground. User Panel Power Supply Outer screen Demand Signal Spool Position Monitor Valve must be connected to ground via subplate Enclosure Connector shell 0V must be connected to ground Wiring connections for M1 valves with enable feature NNote: In applications where the valve must conform to European RFI/EMC regulations, the outer screen (shield) must be connected to the outer shell of the 7 pin connector, and the valve body must be fastened to the earth ground....

Open the catalog to page 10
KBCG-3-1* - 11

Electrical information Current input (M2) Spool position monitor voltage (pin F) will be referenced to the KB valve local ground. User Panel Power Supply Outer screen Demand Signal Spool Position Monitor Valve must be connected to ground via subplate Enclosure Connector shell 0V must be connected to ground Wiring connections for M2 valves with enable feature NNote: In applications where the valve must conform to European RFI/EMC regulations, the outer screen (shield) must be connected to the outer shell of the 7 pin connector, and the valve body must be fastened to the earth ground. Proper...

Open the catalog to page 11
KBCG-3-1* - 12

Hydraulic fluids and Contamination control requirements Contamination control requirements Hydraulic Fluids & Recommendations on contamination control methods and the selection of products to control fluid condition are included in Eaton Hydraulic Fluid Recommendation 03-401-2010 rev 1 . For products in this catalog the recommended levels are: Up to 210 bar (3000 psi) - 18/16/13 Above 210 bar (3000 psi) - 17/15/12 Installation and start-up guidelines The proportional valves in this catalog can be mounted in any attitude but it may be necessary, in certain demanding applications, to ensure...

Open the catalog to page 12
KBCG-3-1* - 13

This page is intentionally left blank EATON Proportional pressure relief valves V-VLPO-MC002-E1 September 2020

Open the catalog to page 13
KBCG-3-1* - 14

This page is intentionally left blank EATON Proportional pressure relief valves V-VLPO-MC002-E1 September 2020

Open the catalog to page 14
KBCG-3-1* - 15

This page is intentionally left blank EATON Proportional pressure relief valves V-VLPO-MC002-E1 September 2020

Open the catalog to page 15

All Eaton Hydraulics catalogs and technical brochures

  1. W Series

    80 Pages

  2. GD5-Series

    24 Pages

  3. KBCG-6-1

    16 Pages

  4. Coils

    14 Pages

  5. Eaton HP50

    4 Pages

  6. E-HOEV-MC001

    68 Pages

  7. E-HOEV

    2 Pages

  8. EH066

    2 Pages

  9. A-HC

    8 Pages

  10. 509200

    4 Pages

  11. E-HOBV

    2 Pages

  12. A-HOAK

    69 Pages

  13. et3000

    19 Pages

  14. ttc

    28 Pages

  15. ETRLD

    20 Pages

  16. x505901

    21 Pages

  17. 509400

    8 Pages

  18. v fifi

    36 Pages

  19. i730

    8 Pages

  20. C001

    23 Pages

  21. XQ5

    20 Pages

  22. E2

    21 Pages

  23. E1

    19 Pages

  24. 1E

    2 Pages

  25. DP

    12 Pages

  26. DBA

    4 Pages

Archived catalogs