Open the catalog to page 1Table of Contents Introduction and application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03 Installation notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 04 Typical section views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05 Moments of inertia and weights. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 06 Conversion factors . . . . . . . . . . . . . . . . . . . . ....
Open the catalog to page 2The new VSQ Vane pump is built to combine the best features of Vane pumps with 0 RPM low speed capable architecture to support efficiency and energy savings. Combined with high speed and high operating pressure features, this pump is an optimal choice over internal gear and piston pumps for industrial applications. Eaton’s VSQ pumps provide continuous pressure ratings up to 280 bar (4060 psi) for the 25 frame size and displacements up to 180 cm3/r (10.98 in3/r) in the double pump configuration. In addition, further reductions in noise levels on an already quiet design offers real possibilities...
Open the catalog to page 3Pump characteristics. Rated pressure Pumps should not be operated at or near rated pressures at idle speeds for extended periods. Localized overheating and damage can result. Never assume pumps in a double, triple or thru-drive pump assembly can be simultaneously loaded to rated pressure. Shaft loading must be checked for excessive torque. Never load or unload a VSQ pump at rates greater than 10,342 bar/sec (150,000 psig/sec), because pump instability could occur. If unloading pump at rates over 5,171 bar/sec (75,000 psig/ sec), make sure inlet pressure does not fall below 0.83 bar (12 psi) absolute...
Open the catalog to page 4Typical sections Single pump example Thru-drive pump example Double pump example EATON VSQ VANE PUMPS V-PUVN-TM001-E6—August 2019
Open the catalog to page 5Conversion factors Pressure rating (Maximum) EATON VSQ VANE PUMPS V-PUVN-TM001-E6—August 2019 www.eaton.com
Open the catalog to page 6Typical sound data 49˚C (120˚F), SAE 10W oil, 0 bar (0 psig) inlet EATON VSQ VANE PUMPS V-PUVN-TM001-E6—August 2019
Open the catalog to page 7Model code - single and thru-drive pumps EE'EE E'E 0 E®50 52 52 5^54 |T| |~2| |~3| |~4| Series designation VSQ1 Vane Pump Single Series Frame size Output shaft coupling Thru-drive units, model code 0 = T 00 None (non thru-drive) [7 Pump type S Single (Options at model codes 551 and 55 56 must be specified for thru-drive units) Inlet port type A SAE J518 4-bolt split flange 10 •Additional displacements available soon 53 Front flange mounting style A SAE B 2-bolt 101,60 (4.000) x 9,4 (0.37) pilot 14,4 (0.57) slots on 146,0 (5.75) bolt circle B SAE C 2-bolt Outlet Port Type A SAE J518 4-bolt flange...
Open the catalog to page 8[T] |~2| [31 [4 Series designation VSQ2 Vane Pump Double Series 20 21 [3] [3] Frame size (rear section) 22 Pump type S Standard *Additional displacements available soon *Additional displacements available soon 27 Front flange mounting style 14,4 (0.57) slots on 146,0 (5.75) bolt circle pilot 17,6 (0.69) slots on 181,0 (713) bolt circle 0 None (standard double pump) Model code - double pumps Output shaft coupling 00 None (standard double pump) Inlet port type A SAE J518 4-split flange Front outlet port type A SAE J518 4-bolt flange Rear outlet port type A SAE J518 4-bolt flange Front outlet port...
Open the catalog to page 9* Verify shaft torque ratings meet or exceed input torque requirements (see page 22). EATON VSQ VANE PUMPS V-PUVN-TM001-E6—August 2019 www.eaton.com
Open the catalog to page 10neral oil SAE 10W, oil temperature 49° C (120° F), 1 bar absolute inlet pressure VSQ vane pumpPerformance data EATON VSQ VANE PUMPS V-PUVN-TM001-E6—August 2019 www.eaton.com
Open the catalog to page 11Typical output flow - industrial Performance data Speed (r/min) Speed (r/min) Speed (r/min) Speed (r/min) EATON VSQ VANE PUMPS V-PUVN-TM001-E6—August 2019 Speed (r/min)
Open the catalog to page 12Typical output flow - industrial Speed (r/min) Speed (r/min) Speed (r/min) Flow (l/min) EATON VSQ VANE PUMPS V-PUVN-TM001-E6—August 2019
Open the catalog to page 13Typical input power - industrial Performance data Speed (r/min) Speed (r/min) Speed (r/min) Speed (r/min) Speed (r/min) EATON VSQ VANE PUMPS V-PUVN-TM001-E6—August 2019 Speed (r/min)
Open the catalog to page 14Typical input power - industrial Speed (r/min) Speed (r/min) Speed (r/min) Speed (r/min) EATON VSQ VANE PUMPS V-PUVN-TM001-E6—August 2019
Open the catalog to page 15VSQ1 25 Single pumps Installation dimensions in mm (in) For shaft dimensions see page 20. In-line port arrangement illustrated. For alternative port arrangements see model code 19 15,4/14,6 (0.607/0.575) "M" is marked if metric port threads No marking if inch port threads Outlet port (dimensions below) Outlet port Inlet port Flange type EATON VSQ VANE PUMPS V-PUVN-TM001-E6—August 2019
Open the catalog to page 16VSQ1 25T Thru-drive pumps Installation dimensions in mm (in) Illustration shows assembly with port configuration C (outlet in line with inlet) as per model code 19 For shaft dimensions see page 20. Rear mount pumps for list of suitable fixed and variable displacement Vickers pumps, see page 56. for details of rear mount and coupling options, see next page. 248,8/246,4 (9.80/9.70) 133,5 (5.25) 39,6 (1.56) 15,4/14,6 (0.607/0.575) "M" is marked if metric port threads No marking if inch port threads øB1 Outlet port Inlet port Outlet port Inlet port Flange type EATON VSQ VANE PUMPS V-PUVN-TM001-E6—August...
Open the catalog to page 17VSQ1 25T Thru-drive pumps rear mount/coupling details Installation dimensions in mm (in) Detail of SAE A flange per model code 12 = C (SAE flange in line with mounting flange.) Coupling options per model code 15 16 and details are given in table below. 248,8/246,4 (9.80/9.70) to front mounting flange face 2 holes tapped 3/8" - 16UNC - 2B thread 19,0 (0.75) min. depth L (distance to snap-ring), see table S see table 10,25 (0.404) Coupling, see table Detail of SAE B flange per model code 12 = C (SAE B flange in line with mounting flange.) Coupling options per model code 15 16 and details are given...
Open the catalog to page 1816 Pages
16 Pages
58 Pages
48 Pages
18 Pages
16 Pages
14 Pages
14 Pages
12 Pages
4 Pages
2 Pages
4 Pages
20 Pages
26 Pages
16 Pages
12 Pages
2 Pages
4 Pages
166 Pages
12 Pages
22 Pages
12 Pages
10 Pages
30 Pages
16 Pages
10 Pages
16 Pages
8 Pages
16 Pages
26 Pages
12 Pages
24 Pages
294 Pages
20 Pages
20 Pages
54 Pages
384 Pages
4 Pages
30 Pages
156 Pages
216 Pages
24 Pages
68 Pages
2 Pages
2 Pages
8 Pages
4 Pages
2 Pages
69 Pages
19 Pages
28 Pages
20 Pages
21 Pages
8 Pages
36 Pages
8 Pages
23 Pages
20 Pages
21 Pages
19 Pages
2 Pages
12 Pages
124 Pages
24 Pages
22 Pages
196 Pages
60 Pages
8 Pages
48 Pages
80 Pages
16 Pages
4 Pages
30 Pages
35 Pages
8 Pages
36 Pages