DG2V-2, DG4V-2 DG17-2, DG21V-2 Segment A - 2

Solenoid Operated Directional Valves DG4V-2 10 Design General description and application benefits These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The features being released with this range are based on Eaton experience with size 3 valves. • Efficient control of high hydraulic powers with low solenoid power consumption. • Low internal leakage reduces power losses, increases system efficiency - the result of improved manufacturing techniques for spools and bores. • High sustained machine productivity and higher...

Open the catalog to page 2
DG2V-2, DG4V-2 DG17-2, DG21V-2 Segment A - 3

Manually Operated Directional Valve DG2/17/21V-2 10 Design General description and application benefits the following application benefits: Eaton directional valves offer versatility of application for the many directional control requirements of hydraulic machinery. Ruggedness of design, manufacturing quality, and worldwide parts and service availability maximize uptime. • Efficient control of high hydraulic powers, ideal for such applications as gate valves. These valves are available in an ISO/DIS 4401-02-02 interface. Lever operated, roller cam and plunger operated models offer • Low...

Open the catalog to page 3
DG2V-2, DG4V-2 DG17-2, DG21V-2 Segment A - 4

Model Code Model Series D – Directional valve G – Subplate/manifold mounted 4 – Solenoid operated V – Pressure rating 250 bar (3600 psi) 2 Interface Spool type Refer page 6 for spool type 4 Spool spring arrangement A – Spring offset, end-to-end AL – Same as “A” but left hand build B – Spring offset, end to center BL – Same as “B” but left hand build C – Spring centered N – No-spring detented 5 Manual Override. Omit if Not required Z – No override 6 Solenoid energization identity Blank – None V – Solenoid “A” is at port “A” end and/or solenoid “B” is at port “B” end, independent of spool...

Open the catalog to page 4
DG2V-2, DG4V-2 DG17-2, DG21V-2 Segment A - 5

two position, detented A B Double solenoid valves, two position, detented Functional Symbols Double solenoid valves, spring centered P T Sol. A Sol. B A Double solenoidBvalves, spring centered Single PA T B Sol. B solenoid valves, Sol. A solenoid at port A end solenoid at p Single solen solenoid at Sol. B Sol. B Double solenoid valves, Single solen A The schematics of the valve function applies to two position, detented solenoid at Transient condition both U.S. and DG4V-2-*N(V) valves European DG4V-2-*N(V) valvesvalves DG4V-2-*A(V) valvesvalves DG4V-2-*AL(V) valvesvalves only valves....

Open the catalog to page 5
DG2V-2, DG4V-2 DG17-2, DG21V-2 Segment A - 6

Functional Symbols Spool Options for DG2/17/21V-2 Spool Options Basic Valve Symbol Usable Spool Options  Transient condition only EATON Solenoid Operated Directional Valve DG**V-2 E-VLV

Open the catalog to page 6
DG2V-2, DG4V-2 DG17-2, DG21V-2 Segment A - 7

Pressure limits: P, A and B ports: using 25W solenoid coils 250 bar (3600 psi) using 12W solenoid coil type HL 165 bar (2400 psi) T port 160 bar (2300 psi) Flow rating: Full power (25W) coil 30 l/min (7.9 USgpm) Low power (12W) coil, type HL 20 l/min (5.3 USgpm) Relative duty factor Continuous; ED = 100% Type of protection Type of protection Coils with ISO 4400 connector fitted correctly IEC 947 class IP65 IEC 947 class IP65 Coil winding Class H Class H Coil encapsulation Class F Class F Permissible voltage fluctuation: Maximum 110% rated Minimum 90% rated Typical response times at 100%...

Open the catalog to page 7
DG2V-2, DG4V-2 DG17-2, DG21V-2 Segment A - 8

Typical with mineral oil at 36 cSt (168 SUS) and a specific gravity of 0.87. Maximum Flow Rates Performance conditions: Looped flow P-A plus B-T (or P-B plus A-T). Solenoid coil warm and operating at 90% rated voltage. Standard, 25W coils Types G, H bar 250 Low Power, 12W coil Type HL psi bar 165 2400 150 2000 Asymmetrical Flow Rates Consult Eaton with applications details if either of the following usages are required: (a) Single flow path, i.e. P-A, P-B, A-T or B-T. Spool Type Curve Number (b) When flow rates between P-A, B-T (or P-B, A-T) are significantly different, e.g. A and B...

Open the catalog to page 8
DG2V-2, DG4V-2 DG17-2, DG21V-2 Segment A - 9

Typical with mineral oil at 36 cSt (168.6 SUS) and a specific gravity of 0.87. Pressure drop Refer to appendix for other viscosities Looped Flow Malfunction Pressure drops in offset positions except where otherwise indicated Pressure Drop Curve Number Spool/spring Code Curve Number EATON Solenoid Operated Directional Valve DG**V-2 E-VLVI-SS

Open the catalog to page 9
DG2V-2, DG4V-2 DG17-2, DG21V-2 Segment A - 10

Pressure Drops Pressure drop Pressure drop Refer to appendix for other viscosities Pressure drops in offset positions except where otherwise indicated Spool/spring arrangement Spool positions covered Both De-energized Energized Both Energized Both De-energized Energized De-energized Energized All De-energized Energized EATON Solenoid

Open the catalog to page 10
DG2V-2, DG4V-2 DG17-2, DG21V-2 Segment A - 11

Dimensions shown in mm (inches) Single solenoid models DG4V-2-A(L) DG4V-2-B(L) Spring offset Dimensions are shown for standard connectors. For connectors with rectifiers and/ or LED this dimension varies up to 84,0 (3.31) maximum. Refer to double solenoid models below for port designations. Double solenoid models DG4V-2-C Spring centered DG4V-2-N No-spring detented Port B EATON Solenoid Operated Directional Valve DG**V-2 E-VLVI-SS001-E1 October 2015

Open the catalog to page 11
DG2V-2, DG4V-2 DG17-2, DG21V-2 Segment A - 12

Dimensions shown in mm (inches) Right hand assembly Port A 9,00 (0.35) Port T Left hand assembly Port A (Dimensions not shown are same as DG17V-2, above) Note: Load must be applied axially to plunger 2,45 (0.10) Max. stroke 2,25 (0.08) Nom. stroke (Dimensions not shown are same as DG17V-2, above) 15 Max. cam angle 32,00 (1.26) 18 Roller The mounting bolts for this housing may be removed and the housing and roller rotated 90° to suit the application. EATON Solenoid Operated Directional Valve DG**V-2 E-VLVI-SS001-E1 October 2015

Open the catalog to page 12
DG2V-2, DG4V-2 DG17-2, DG21V-2 Segment A - 13

Electrical Plugs and Connectors ISO 4400 (DIN 43650) Order separately by part number. A flying lead connector and an Amp Jr Timer connector are also available. Contact your Eaton representative for details. The cable entry on these plugs can be repositioned to 900 intervals by reassembly of the contact holder relative to the plug housing. The cable entry is PG 11 for cable 6-10 mm (0.24” to 0.39” dia). Connectors w/o indicator lights Part No. Used on solenoid coil Black Gray Connectors with LED Voltage Part Number Gray (sol. A) Connectors with rectifier Coil code AC input voltage 50/60 Hz...

Open the catalog to page 13

All Eaton Hydraulics catalogs and technical brochures

  1. W Series

    80 Pages

  2. GD5-Series

    24 Pages

  3. KBCG-6-1

    16 Pages

  4. KBCG-3-1*

    16 Pages

  5. Coils

    14 Pages

  6. Eaton HP50

    4 Pages

  7. E-HOEV-MC001

    68 Pages

  8. E-HOEV

    2 Pages

  9. EH066

    2 Pages

  10. A-HC

    8 Pages

  11. 509200

    4 Pages

  12. E-HOBV

    2 Pages

  13. A-HOAK

    69 Pages

  14. et3000

    19 Pages

  15. ttc

    28 Pages

  16. ETRLD

    20 Pages

  17. x505901

    21 Pages

  18. 509400

    8 Pages

  19. v fifi

    36 Pages

  20. i730

    8 Pages

  21. C001

    23 Pages

  22. XQ5

    20 Pages

  23. E2

    21 Pages

  24. E1

    19 Pages

  25. 1E

    2 Pages

  26. DP

    12 Pages

  27. DBA

    4 Pages

Archived catalogs