video corpo

C001

C001
1 / 23 PagesView full catalog

C001

Product catalog summary
Design Features
  • Heavy Duty Rod Cartridge: Constructed from SAE 660 bronze with options for aluminum bronze, ensuring durability.
  • Rod Seal and Wiper: Hydraulic systems use high durometer urethane seals; pneumatic systems use nitrile U-cup seals, with metallic rod scrapers as an option.
  • Secured Piston: Made from ductile iron, with options for steel pistons with wear bands or bronze overlay.
  • Piston Seals: Bi-directional nitrile seals with wear-bands to prevent pressure traps and sideloading.
  • High Yield Piston Rod: Made from C1045/50 microalloy steel, chrome-plated for durability.
  • Cushions: Adjustable design for smooth deceleration, not available for 2.00” bore with 1.375” rod.
  • High Yield Steel Tubing: Available with chrome-plated bores for hydraulic systems.
  • Body Flanges: Steel construction with high-strength bolts, threaded for maximum strength.
Specifications
  • Bore Sizes: 2” - 16”
  • Piston Rod Diameter: 1” - 10”
  • Pressure Ratings: MM- 2,000 psi, WM- 3,000 psi, AM- 250 psi
Model Code

The model code is a 16-digit alphanumeric system that describes the cylinder's specifications, simplifying re-ordering and identification.

How to Order

Use the 16-digit model code for standard cylinders. For custom options, use 'X' in the appropriate position and provide a detailed description.

Mounting Style & Installation Dimensions

Various mounting styles are available, each with specific dimensions and configurations for different applications.

Seal Configurations and Materials

Outlines various piston and rod seal configurations for different temperature ranges and fluid applications. Key materials include urethane, PTFE, nitrile, and flurocarbon.

Port and Cushion Selection

Details port codes and cushion options for different cylinder series, emphasizing the importance of correct selection based on mounting style.

Buckling and Load Analysis

Includes a buckling chart to determine maximum allowable length 'L' for cylinders under different pressures, advising consultation for pressures above 3000 psi.

Threaded Flange Design

Introduces the new Vickers threaded flange design, enhancing durability and safety, aligning with ISO 6022 standards.

General Information

Technical guide from Eaton Corporation, providing detailed specifications and engineering data for the Vickers Mill Type Cylinder Series AM/MM/WM.

See more

Catalog excerpts

C001-1

Hydraulic and Pneumatic Cylinders Heavy-Duty Imperial Mill Type Catalog Series AM/MM/WM

 Open the catalog to page 1
C001-3

Design Features SPECIFICATIONS Bore Sizes: 2˝ - 16˝ Piston Rod Dia.: 1˝ - 10˝ Pressure Ratings: D MM- 2,000 psi Nominal Hydraulic Service A E WM- 3,000 psi Nominal Hydraulic Service AM- 250 psi Pneumatic Service B C G F H F A. Heavy Duty Rod Cartridge • SAE 660 bronze rod cartridge is pilot-fitted into the head and incorporates inboard and outboard bearing areas. C. Secured Piston E. High Yield Piston Rod G. High Yield Steel Tubing • One piece pilot-fitted ductile iron material. • High yield, turned, ground and polished C1045/50 microalloy steel. Hydraulic: • Piston to rod set screw staking available...

 Open the catalog to page 3
C001-4

Model Code All dimensions are in inches. W M 10 K M 5 N 3 K W 10 8 P C 3, 4 1, 2 1, 2 Mill Cylinder Series WM – 3000 psi Hydraulic MM – 2000 psi Hydraulic 5, 6 5, 6 7 8 Bore and Rod Diameter 9 7 10 11 12, 13, 14 15,16 Rod End Types Mounting Style XX – Custom 01 – Side Lug (Foot) Sealing Systems Code Bore Rod Code - Rod End Style DE DH 2 2 1 1-3/8 N - Normal 2 - Short Female UN Thread L - Low Friction FH FL FM 3 3 3 1-3/8 1-3/4 2 AM – 250 psi Pneumatic 3, 4 8 T - High Temperature C - Classic (Chevron/C.I. Rings) 5 - Small Male UN Thread 9 Ports For maximum reliability, SAE ports are recommended....

 Open the catalog to page 4
C001-5

Model Code All dimensions are in inches. W M 10 K M 5 N 3 K W 10 8 P C 3, 4 1, 2 10 11 Port Location Ports are located as shown below when viewing cylinder from head end (mounting end of double rod cylinder). Some mounting styles have port location restrictions. 1 4 2 3 Code Head Cap K L M N P R S T U V W Y 1 2 3 4 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 5, 6 Cushion Location Code Head Cap A B C D E F G H J K L M N P R S T U V W Y 1 2 3 4 1 2 3 4 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 7 8 9 10 11 12, 13, 14 12, 13, 14 15,16 Cylinder Stroke...

 Open the catalog to page 5
C001-6

How To Order Standard Cylinders Eaton® has created an easy system for ordering Vickers™ Series AM/MM/WM Cylinders. This system has been developed to improve our service to you. The model code consists of sixteen alpha-numeric digits which fully describe the most common standard options offered on Series AM/MM/WM cylinders. To specify your Series AM/MM/WM cylinder, review the following pages for a full description of each option available and select the desired code. This model code system will: • Simplify the re-order process. Each Vickers cylinder is assigned a sixteen digit model code. That...

 Open the catalog to page 6
C001-17

Common Options Section Sealing Systems Four different sealing systems are available in Series AM/MM/WM cylinders. Seal Code N Determine the correct seal code for your application, then enter it as item 8 in the model code. Rod Seal Configuration Polypak seal (1) Buffer Seal (1) Wiper (1) Buffer Seal (2) Wiper (1) Piston Seal Configuration Temp ˚F Capped T-Seal (1) -20 to 200 Wearbands Capped T-Seal (1) Wearbands -20 to 200 T Polypak Seal (1) Buffer Seal (1) Wiper (1) Capped T-Seal (1) Wearbands -20 to 400 Flurocarbon PTFE C Chevron Cast Iron Rings -20 to 200 Nitrile L Seal Material Urethane PTFE...

 Open the catalog to page 17
C001-19

Common Options Port and Cushion Selection 1 Port and cushion locations are identified by viewing the cylinder from the head end (or from the mounting end of double rod cylinder). The location numbers are shown to the right. Certain port and cushion locations cannot be specified with some mounting styles. The table below indicates which of the head and cap port location are available for each Series AM/MM/WM mounting style. 4 2 3 Port Location Availability Chart MOUNTING STYLE CODE DESCRIPTION HEAD LOCATION 1 2 3 4 01 09 10 11 14 15 24 25 33 34 41 Side Lug Head Rectangular Cap Clevis Spherical...

 Open the catalog to page 19
C001-21

Application/ Engineering Data Threaded Flange Design Eaton Vickers Series AM/MM/WM cylinders now come standard from factory with flanges threaded to the body tube. Due to a thicker, stronger steel flange design, the new Vickers threaded flange design offers over 22% greater material yield strength compared to our previous welded flange design. In most bore size ranges and applications, the Vickers threaded flange design has superior bending stress capacity, durability, and increased safety factors of shear over both the previous Vickers welded flange design as well as the ISO 6022 (250 bar) threaded...

 Open the catalog to page 21
C001-22

22 EATON Vickers Mill Type Cylinder Series AM/MM/WM V-CYMG-MC001-E March 2007

 Open the catalog to page 22
C001-23

Eaton 14615 Lone Oak Road Eden Prairie, MN 55344 USA Tel: 952 937-9800 Fax: 952 974-7722 www.hydraulics.eaton.com Eaton 20 Rosamond Road Footscray Victoria 3011 Australia Tel: (61) 3 9319 8222 Fax: (61) 3 9318 5714 Eaton Dr.-Reckeweg-Str. 1 D-76532 Baden-Baden Germany Tel: (49) 7221 682-0 Fax: (49) 7221 682-788 © 2007 Eaton Corporation All Rights Reserved Printed in USA Document No. V-CYMG-MC001-E Supersedes V-CC-MC-001-E March 2007

 Open the catalog to page 23

All Eaton Hydraulics catalogs and technical brochures

  1. KBCG-6-1

    16  Pages

  2. KBCG-3-1*

    16  Pages

  3. Coils

    14  Pages

  4. Eaton HP50

    4  Pages

  5. E-HOEV-MC001

    68  Pages

  6. E-HOEV

    2  Pages

  7. EH066

    2  Pages

  8. A-HC

    8  Pages

  9. 509200

    4  Pages

  10. E-HOBV

    2  Pages

  11. A-HOAK

    69  Pages

  12. et3000

    19  Pages

  13. ttc

    28  Pages

  14. ETRLD

    20  Pages

  15. x505901

    21  Pages

  16. 509400

    8  Pages

  17. v fifi

    36  Pages

  18. i730

    8  Pages

  19. XQ5

    20  Pages

  20. E2

    21  Pages

  21. E1

    19  Pages

  22. 1E

    2  Pages

  23. DP

    12  Pages

Archived catalogs

  1. GD5-Series

    24  Pages

  2. Power amplifier

    60  Pages

  3. W Series

    80  Pages

  4. DBA

    4  Pages

  5. Accumulators

    30  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.