Catalog excerpts
Vickers® Accessories Power Amplifiers for PVH-EDC Pumps EEA-EDC-436-A*-14 Design General Description These amplifiers are designed for controlling Vickers PVH pumps with electronic displacement control. A1 - For use with PVH57 & 74 A2 - For use with PVH98 A3 - For use with PVH131 The pulse-width-modulated power output stage drives a single solenoid proportional spool valve which hydraulically controls the pump yoke position. Feedback of the yoke position and pump output is from a rotary feedback transducer which closes the control loop and ensures accurate pump output flow. Analog command input signals can be non-inverting current, or non-inverting, inverting or differential voltages. The amplifier requires a power supply of 24V DC and is enabled by a 24V logic signal. The ramp is normally enabled but can be selectively disabled by suitable wiring to an external switch. The amplifier front panel contains LEDs showing the status of power, control supply and outputs. Potentiometers for adjusting ramp and gain are also mounted in the front panel. Features D Constant current amplifier D Voltage or current command signals D 1 ramp for acceleration and deceleration D 24V DC power supply D Pulse-width-modulated coil drive D Wide supply voltage range and tolerance to ripple D Low supply voltage protection D Ramp setting unaffected by gain adjustment. Panel Display LEDs 1. 2. 3. 4. 5. 6. 24V power supply input, green 15V control supply output, green Output (solenoid) enabled, yellow Overload, red Transducer failure, red Output level to solenoid, yellow 24 15V V ma x 7. Gain Potentiometers 8. Ramp Monitor Points 9. Monitor point H- conditioned command signal 10. Common ground 0VH 11. Monitor point yoke position H ∅2,0 (0.0787 dia.) sockets 5092.00/EN/0298/A
Open the catalog to page 1Operating Data (Amplifier) Power (input) supply Control (output) supply: Command signal inputs: Direct voltage pins Inverting voltage pin Current pin Voltage range Input impedance (voltage) Current range Input impedance (current) Standing solenoid current at zero command signal Gain adjustment Ramp time adjustment, linear: Factory setting Adjustment per solenoid Dither Feedback from yoke transducer to b14 20 to 34V DC x 40W max. 24V DC nominal <4V pk-to-pk ripple Amplifier shuts down below 19V +15V x 50 mA max. +10V x 5 mA max. –10V x 5 mA max. All outputs short-circuit protected b8, b6,...
Open the catalog to page 2Circuit and Connections Eurocard Amplifier = +24V z6 Current command output enable 100Ω Command singal inputs (See table) zbd32 zbd30 ground z12 output enable z24 Overload low voltage = + b6 b8 b10 z8 z10 47kΩ ramp gain z4 PE Supply green PE green b26 Power stage Voltage command Ramp Controlenable zero b20 24V DC S Power b28 dither z28 Output z26 z22 b14 b16 PWM b4 S red z2 +10V 5 mA b2 –10V 5 mA z22 +15V 50 mA PE white orange black S b12 Link to disable ramp Yoke position monitor point on front panel Command signal monitor point (conditioned) on front panel Pump Assembly “F” case drain “B”...
Open the catalog to page 3Command Signals/Installation Dimensions for Amplifier Command Signals Type Input pins Signal polarity Non-inverting voltages b6/8/10 or z8 + Non-inverting current z6 + z10 – One of b6/8/10 or z8 Secondary pins ref. + bz4 Inverting voltage Differential voltage Link one of b6/8/10 or z8 to bz4 One of b6/8/10 or z8 z10 and link one of b6/8/10 to bz4 Installation Dimensions Plug-in unit of 3U height, to IEC 297 3rd angle projection mm (inch) DIN 41612 F48 male connector 7,92 (0.31) z-pin row b-pin row d-pin row Components envelope M2,5 x 11 (0.43) long collar screws supplied with panel for...
Open the catalog to page 4All Eaton Hydraulics catalogs and technical brochures
-
W Series
80 Pages
-
Eaton STC® Connectors Catalog
48 Pages
-
Eaton VSQ Vane Pumps
28 Pages
-
EHST-3-40 Series
8 Pages
-
Power amplifier
60 Pages
-
Fluid Conveyance Master Catalog
196 Pages
-
KBH-05 10 Series
22 Pages
-
GD5-Series
24 Pages
-
Motion control valves
124 Pages
-
KBCG-6-1
16 Pages
-
KBCG-3-1*
16 Pages
-
LifeSense Master Catalog
58 Pages
-
Electronic Feedback Cylinders
48 Pages
-
TLC Slip Detect Control Panel
18 Pages
-
Success made simple
16 Pages
-
Coils
14 Pages
-
2 Speed axial piston motor
14 Pages
-
Hydraulics Portfolio Brochure
12 Pages
-
Eaton HP50
4 Pages
-
Eaton Easy Couple H201
2 Pages
-
Eaton Delta motor
4 Pages
-
Eaton Weatherhead Core
20 Pages
-
Eaton Food Processing
26 Pages
-
Eaton Aeroquip Core
16 Pages
-
Eaton Engineered Solutions
12 Pages
-
Eaton EC600 X-FLEX
2 Pages
-
Press control blocks
4 Pages
-
Eaton Brass Products Master Catalog
166 Pages
-
Eaton® Industrial Cylinders
12 Pages
-
Airflex® Water-Cooled Brakes
22 Pages
-
Airflex® DBB & DBA Brakes
12 Pages
-
DG4V-3 70 Design Segment D
10 Pages
-
DG3V-8 & DG5V-8 Segment J
30 Pages
-
DG3V-7 & DG5V-7 Segment I
16 Pages
-
DG3V-5 & DG5V-5 Segment H
16 Pages
-
DG3V-3, DG4VP-3 Segment F
10 Pages
-
DG5V-7 30 Design & DG3V-7 20
16 Pages
-
Eaton Floating Housing Brake
8 Pages
-
Track Drive Motor - 2-Speed
16 Pages
-
Hydraulic Remote Controls
26 Pages
-
CNG Hose Catalog
12 Pages
-
External Gear Pump – GD5 Series
24 Pages
-
Low Speed, High Torque Motors
294 Pages
-
BECODISC Stacked Disc Cartridges
20 Pages
-
X20 Series 220 - Pump Catalog
20 Pages
-
Eaton Winner LQA Program - EMEA
54 Pages
-
Eaton Aeroquip Master Catalog
384 Pages
-
Eaton Guardian Seal
4 Pages
-
Accumulators Master Catalog
30 Pages
-
Filters Master Catalog
156 Pages
-
Industrial Hose and Tubing
216 Pages
-
Eaton?s Pump and Motor Products
24 Pages
-
E-HOEV-MC001
68 Pages
-
E-HOEV
2 Pages
-
EH066
2 Pages
-
A-HC
8 Pages
-
E-HOBV
2 Pages
-
A-HOAK
69 Pages
-
et3000
19 Pages
-
ttc
28 Pages
-
ETRLD
20 Pages
-
x505901
21 Pages
-
509400
8 Pages
-
v fifi
36 Pages
-
i730
8 Pages
-
C001
23 Pages
-
XQ5
20 Pages
-
E2
21 Pages
-
E1
19 Pages
-
1E
2 Pages
-
DP
12 Pages
-
DBA
4 Pages
Archived catalogs
-
Accumulators
30 Pages
-
GEAR PUMPS AND MOTORS
35 Pages
-
ETON MOBILE VALVES
8 Pages
-
Hydro-Line® N5 Series Cylinders
36 Pages