Catalog excerpts
Powering Business Worldwide
Open the catalog to page 1Content Model codes Control options Pressure & Flow (Load Sense) Compensator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Pressure Compensator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Remote Pressure Control (RPC). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Electronic Displacement Control (EDC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 EH Inverse Proportional Pressure Control (IPPC). . . . . . . . . . . . . . . . . . . . . . . . . . 10 Electronic Destroke...
Open the catalog to page 3Introduction 220 Series Piston Pump The Eaton® X20 portfolio of open-circuit piston pumps is built to maximize machine performance and productivity. With sophisticated controls that enhance system efficiency and a compact design that delivers incredible power, the X20 portfolio empowers mobile machine operators to do more work in less time using less fuel. Sophisticated controls that improve performance while optimizing efficiency. Excellent pressure responsiveness – The X20 portfolio delivers the fastest response and recovery times in the opencircuit piston segment, helping customers get...
Open the catalog to page 4220 Series Mobile Piston Pump AEC - 220 Series open circuit piston pump 05 - 2 Bolt B, 22.2 mm (0.88) dia . keyed shaft 09 - 2 Bolt B, 13 Tooth 16/32 Spline 31 - 2 Bolt B, 25.4 mm(1.00 in) dia . straight keyed 34 - 2 Bolt B, 15 Tooth 16/32 spline 48 - 2 Bolt A, 11 Tooth 16/32 spline, 38 mm [1.5 in] ext . [18cc only] 49 - 2 Bolt A, 1:8 Taper 16.66 mm [0.655 in] dia . 39.7 [1.56] ext [for 18cc AG variant only] 50 - 2 Bolt A, 9 Tooth 16/32 spline [for 18cc only] 51 - 2 Bolt A, 19.02 mm [ . 749 in] dia . keyed shaft, 32 mm [1.26 in] ext . [for 18cc only] 52 - 2 Bolt A, 15.85 mm [ . 324 in] dia...
Open the catalog to page 5220 Series Mobile Piston Pump HHH HE® H [s ^ 1011 12 H HH HU 1819 2921 29292428 Maximum displacement option* 01 - Standard displacement (as given in code title) 02 - External manual stroke adjustment 2829 Auxiliary (rear) mount & output shaft [for 28cc only] 00 - No auxiliary mounting features AG - Auxiliary mount ready with cover plate 1 - Standard viton shaft seal 2 - Nitrile shaft seal AB - Swash position sensor AE - Rear port end cover with integrated priority and shuttle valve [for 18cc AG pump only] 01 - Standard Eaton identification box packaging Design level Second design 1...
Open the catalog to page 6General performance specifications 1 Less than 10% of duty cycle. 2 Momentary system pressure spikes only. 3 Ratings based on flange ports. 4 Standard non-through drive pump. 5 Bearing life ratings at rated speed - 1 bar abs (0 psig) inlet. Will vary based on thrust and side loads. Inlet pressure, case pressure, and operating temperature requirements Inlet pressure Hydraulic fluids For more information, see Eaton publication 579. For operation on other alternative or environmentally friendly fluids, please contact your Eaton Representative. EATON 220 MOBILE PISTON PUMP CATALOG...
Open the catalog to page 7Control options Pressure & Flow (Load Sense) Compensator for AEC018 AG variant only The Agricultural tractor variant of 220 pump has a shuttle valve integral into pump end cover which senses the highest load of the two-work circuit and a priority valve to set the flow priority. For tractor application steering is given priority over other auxiliary functions like hitch circuit for implements. Fluid output from the pump end cover enters into the priority valve before reaching to system. Integrated priority valve gives the pump flow priority to Steering system over the Hitch valve of the...
Open the catalog to page 8The pump will provide flow & pressure matching of pump output to system load demand, maximizing efficiency and improving load metering characteristics of any directional control valve installed between the pump and the load . Load sensing ensures that the pump always provides only the amount of flow needed by the load . The pump operating pressure adjusts to the load pressure plus a pressure differential required for the load sense margin . When the system is not demanding flow, the load sense control will operate in low pressure zero flow, energy saving stand-by mode . The differential...
Open the catalog to page 9The pump will provide a continuously modulated flow to meet changing load demands at a pre-adjusted compensator pressure . At pressures below the compensator setting, the pump will operate at maximum displacement . See model code position #16, 17 for compensator pressure ranges . Warning: • When adjusting the pressure limiter, install a 0 to 350 bar (0 to 5000 psi) gage in the outlet gage port and limit the pressure setting to the continuous rated pressure for the pump displacement . It is possible to adjust the pressure compensator beyond the rated pressure of the pump . Doing so, may void...
Open the catalog to page 10Remote relief valve is to be connected to pilot port "J" through necessary external piping . Standard differential pressure of 20 bar is set at RPC spool . The required outlet pressure (below 280 bar) can be set by adjusting remote relief valve setting . Once pressure reaches preset value, flow across remote relief valve starts, this results in RPC spool movement due to pressure imbalance . This will de-stroke the pump to maintain the set pressure Secondary fixed pressure compensator is provided to limit the max pressure setting as a fail safe measure Note • Flow Compensator is not...
Open the catalog to page 11Pump displacement can be controlled infinitely, as per the current signal provided to the solenoid control valve . The integrated pump control makes use of an external current signal to vary the pump displacement . This control has an proportional characteristic i . e . with increasing current signal, the displacement increases proportionately This control is with manual override . Based on fail safe condition there are two types: Min type (EP): Return to min displacement in case of power loss . Max type (EPD): Return to max displacement in case of power loss Warning: • When adjusting the...
Open the catalog to page 12All Eaton Hydraulics catalogs and technical brochures
-
W Series
80 Pages
-
Eaton STC® Connectors Catalog
48 Pages
-
Eaton VSQ Vane Pumps
28 Pages
-
EHST-3-40 Series
8 Pages
-
Power amplifier
60 Pages
-
Fluid Conveyance Master Catalog
196 Pages
-
KBH-05 10 Series
22 Pages
-
GD5-Series
24 Pages
-
Motion control valves
124 Pages
-
KBCG-6-1
16 Pages
-
KBCG-3-1*
16 Pages
-
LifeSense Master Catalog
58 Pages
-
Electronic Feedback Cylinders
48 Pages
-
TLC Slip Detect Control Panel
18 Pages
-
Success made simple
16 Pages
-
Coils
14 Pages
-
2 Speed axial piston motor
14 Pages
-
Hydraulics Portfolio Brochure
12 Pages
-
Eaton HP50
4 Pages
-
Eaton Easy Couple H201
2 Pages
-
Eaton Delta motor
4 Pages
-
Eaton Weatherhead Core
20 Pages
-
Eaton Food Processing
26 Pages
-
Eaton Aeroquip Core
16 Pages
-
Eaton Engineered Solutions
12 Pages
-
Eaton EC600 X-FLEX
2 Pages
-
Press control blocks
4 Pages
-
Eaton Brass Products Master Catalog
166 Pages
-
Eaton® Industrial Cylinders
12 Pages
-
Airflex® Water-Cooled Brakes
22 Pages
-
Airflex® DBB & DBA Brakes
12 Pages
-
DG4V-3 70 Design Segment D
10 Pages
-
DG3V-8 & DG5V-8 Segment J
30 Pages
-
DG3V-7 & DG5V-7 Segment I
16 Pages
-
DG3V-5 & DG5V-5 Segment H
16 Pages
-
DG3V-3, DG4VP-3 Segment F
10 Pages
-
DG5V-7 30 Design & DG3V-7 20
16 Pages
-
Eaton Floating Housing Brake
8 Pages
-
Track Drive Motor - 2-Speed
16 Pages
-
Hydraulic Remote Controls
26 Pages
-
CNG Hose Catalog
12 Pages
-
External Gear Pump – GD5 Series
24 Pages
-
Low Speed, High Torque Motors
294 Pages
-
BECODISC Stacked Disc Cartridges
20 Pages
-
X20 Series 220 - Pump Catalog
20 Pages
-
Eaton Winner LQA Program - EMEA
54 Pages
-
Eaton Aeroquip Master Catalog
384 Pages
-
Eaton Guardian Seal
4 Pages
-
Accumulators Master Catalog
30 Pages
-
Filters Master Catalog
156 Pages
-
Industrial Hose and Tubing
216 Pages
-
Eaton?s Pump and Motor Products
24 Pages
-
E-HOEV-MC001
68 Pages
-
E-HOEV
2 Pages
-
EH066
2 Pages
-
A-HC
8 Pages
-
509200
4 Pages
-
E-HOBV
2 Pages
-
A-HOAK
69 Pages
-
et3000
19 Pages
-
ttc
28 Pages
-
ETRLD
20 Pages
-
x505901
21 Pages
-
509400
8 Pages
-
v fifi
36 Pages
-
i730
8 Pages
-
C001
23 Pages
-
XQ5
20 Pages
-
E2
21 Pages
-
E1
19 Pages
-
1E
2 Pages
-
DP
12 Pages
-
DBA
4 Pages
Archived catalogs
-
Accumulators
30 Pages
-
GEAR PUMPS AND MOTORS
35 Pages
-
ETON MOBILE VALVES
8 Pages
-
Hydro-Line® N5 Series Cylinders
36 Pages