Powering Business Worldwide
Open the catalog to page 1Content Model codes Control options Pressure & Flow (Load Sense) Compensator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Pressure Compensator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Remote Pressure Control (RPC). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Electronic Displacement Control (EDC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 EH Inverse Proportional Pressure Control (IPPC). . . . . . . . . . . . . . . . . . . . . . . . . . 10 Electronic Destroke (Cold...
Open the catalog to page 3Introduction 220 Series Piston Pump The Eaton® X20 portfolio of open-circuit piston pumps is built to maximize machine performance and productivity. With sophisticated controls that enhance system efficiency and a compact design that delivers incredible power, the X20 portfolio empowers mobile machine operators to do more work in less time using less fuel. Sophisticated controls that improve performance while optimizing efficiency. Excellent pressure responsiveness – The X20 portfolio delivers the fastest response and recovery times in the opencircuit piston segment, helping customers get the...
Open the catalog to page 4220 Series Mobile Piston Pump AEC - 220 Series open circuit piston pump 05 - 2 Bolt B, 22.2 mm (0.88) dia . keyed shaft 09 - 2 Bolt B, 13 Tooth 16/32 Spline 31 - 2 Bolt B, 25.4 mm(1.00 in) dia . straight keyed 34 - 2 Bolt B, 15 Tooth 16/32 spline 48 - 2 Bolt A, 11 Tooth 16/32 spline, 38 mm [1.5 in] ext . [18cc only] 49 - 2 Bolt A, 1:8 Taper 16.66 mm [0.655 in] dia . 39.7 [1.56] ext [for 18cc AG variant only] 50 - 2 Bolt A, 9 Tooth 16/32 spline [for 18cc only] 51 - 2 Bolt A, 19.02 mm [ . 749 in] dia . keyed shaft, 32 mm [1.26 in] ext . [for 18cc only] 52 - 2 Bolt A, 15.85 mm [ . 324 in] dia ....
Open the catalog to page 5220 Series Mobile Piston Pump HHH HE® H [s ^ 1011 12 H HH HU 1819 2921 29292428 Maximum displacement option* 01 - Standard displacement (as given in code title) 02 - External manual stroke adjustment 2829 Auxiliary (rear) mount & output shaft [for 28cc only] 00 - No auxiliary mounting features AG - Auxiliary mount ready with cover plate 1 - Standard viton shaft seal 2 - Nitrile shaft seal AB - Swash position sensor AE - Rear port end cover with integrated priority and shuttle valve [for 18cc AG pump only] 01 - Standard Eaton identification box packaging Design level Second design 1 ^Additional...
Open the catalog to page 6General performance specifications 1 Less than 10% of duty cycle. 2 Momentary system pressure spikes only. 3 Ratings based on flange ports. 4 Standard non-through drive pump. 5 Bearing life ratings at rated speed - 1 bar abs (0 psig) inlet. Will vary based on thrust and side loads. Inlet pressure, case pressure, and operating temperature requirements Inlet pressure Hydraulic fluids For more information, see Eaton publication 579. For operation on other alternative or environmentally friendly fluids, please contact your Eaton Representative. EATON 220 MOBILE PISTON PUMP CATALOG E-PUOV-TP001-E9...
Open the catalog to page 7Control options Pressure & Flow (Load Sense) Compensator for AEC018 AG variant only The Agricultural tractor variant of 220 pump has a shuttle valve integral into pump end cover which senses the highest load of the two-work circuit and a priority valve to set the flow priority. For tractor application steering is given priority over other auxiliary functions like hitch circuit for implements. Fluid output from the pump end cover enters into the priority valve before reaching to system. Integrated priority valve gives the pump flow priority to Steering system over the Hitch valve of the tractor....
Open the catalog to page 8The pump will provide flow & pressure matching of pump output to system load demand, maximizing efficiency and improving load metering characteristics of any directional control valve installed between the pump and the load . Load sensing ensures that the pump always provides only the amount of flow needed by the load . The pump operating pressure adjusts to the load pressure plus a pressure differential required for the load sense margin . When the system is not demanding flow, the load sense control will operate in low pressure zero flow, energy saving stand-by mode . The differential pressure...
Open the catalog to page 9The pump will provide a continuously modulated flow to meet changing load demands at a pre-adjusted compensator pressure . At pressures below the compensator setting, the pump will operate at maximum displacement . See model code position #16, 17 for compensator pressure ranges . Warning: • When adjusting the pressure limiter, install a 0 to 350 bar (0 to 5000 psi) gage in the outlet gage port and limit the pressure setting to the continuous rated pressure for the pump displacement . It is possible to adjust the pressure compensator beyond the rated pressure of the pump . Doing so, may void the...
Open the catalog to page 10Remote relief valve is to be connected to pilot port "J" through necessary external piping . Standard differential pressure of 20 bar is set at RPC spool . The required outlet pressure (below 280 bar) can be set by adjusting remote relief valve setting . Once pressure reaches preset value, flow across remote relief valve starts, this results in RPC spool movement due to pressure imbalance . This will de-stroke the pump to maintain the set pressure Secondary fixed pressure compensator is provided to limit the max pressure setting as a fail safe measure Note • Flow Compensator is not available...
Open the catalog to page 11Pump displacement can be controlled infinitely, as per the current signal provided to the solenoid control valve . The integrated pump control makes use of an external current signal to vary the pump displacement . This control has an proportional characteristic i . e . with increasing current signal, the displacement increases proportionately This control is with manual override . Based on fail safe condition there are two types: Min type (EP): Return to min displacement in case of power loss . Max type (EPD): Return to max displacement in case of power loss Warning: • When adjusting the pressure...
Open the catalog to page 1216 Pages
16 Pages
58 Pages
48 Pages
18 Pages
16 Pages
14 Pages
14 Pages
12 Pages
4 Pages
2 Pages
4 Pages
20 Pages
26 Pages
16 Pages
12 Pages
2 Pages
4 Pages
166 Pages
12 Pages
22 Pages
12 Pages
10 Pages
30 Pages
16 Pages
10 Pages
16 Pages
8 Pages
16 Pages
26 Pages
12 Pages
24 Pages
294 Pages
20 Pages
20 Pages
54 Pages
384 Pages
4 Pages
30 Pages
156 Pages
216 Pages
24 Pages
68 Pages
2 Pages
2 Pages
8 Pages
4 Pages
2 Pages
69 Pages
19 Pages
28 Pages
20 Pages
21 Pages
8 Pages
36 Pages
8 Pages
23 Pages
20 Pages
21 Pages
19 Pages
2 Pages
12 Pages
124 Pages
24 Pages
22 Pages
196 Pages
60 Pages
8 Pages
28 Pages
48 Pages
80 Pages
16 Pages
4 Pages
30 Pages
35 Pages
8 Pages
36 Pages