Eaton Tubular Backwashing AFC AFR & F-Series Filters
14Pages

{{requestButtons}}

Catalog excerpts

Eaton Tubular Backwashing AFC AFR & F-Series Filters - 1

Tubular Backwashing Filter AFC, AFR & F-Series Reduce Waste, Improve Process Efficiency & Increase Product Quality TUBULAR BACKWASHING FEATURES & BENEFITS • Tight retentions (as low as 1 micron) with high flow rates— ideal for a wide range of process liquids and parameters • Eliminates the need for disposable media including bags and cartridges—reduces disposal costs, materials loss, labor, and inventory • Choice of configurations—available solutions to optimize your system for almost any filtration challenge • Modular scalable systems—your system can grow with your application demands • Automated clean-in-place operation—optimizes cleaning frequency and reduces labor demands • Wide range of operating pressures—capable of reliable operation and performance up to 1,000 psi (69 bar) Industry Leading Family of Solutions Eaton offers a full line of tubular backwashing solutions to meet your specific application demands and business needs. From the high-capacity AFR-Series for high flow in a compact footprint, to our simple single tube AFC-Series for stand-alone applications with low solids loading, there is an Eaton solution for any process. All Eaton filters are engineered for the best performance and value in every application. Barrier Filtration Backwash Cleaning Barrier filtration uses either stainless steel or a fabric screen, selected for its retention and flow properties. This filtration media, within the filter housing, collects debris on its surface because the liquid flows inward. Contaminants on the surface slowly form a barrier, capable of removing smaller particles. The core principle behind backwashing, when automated, is that the filters are designed to initiate a backwash sequence when the differential pressure reaches its set point. The flow of liquid is reversed, dislodging the debris that has built up on the surface of the filter media. A drain header, located at the base of the filter, provides an outlet for the debris to be purged from the system. TYPICAL APPLICATIONS • city water lines • hot condensate • chiller water • fresh water • whitewater / shower water • cip fluids • papermaking wet end starch • pelletizer water • single and duo tubular filters for a wide range of applications up to 1000 psi and high viscosity applications

Open the catalog to page 1
Eaton Tubular Backwashing AFC AFR & F-Series Filters - 2

Tubular Backwashing Filter Process liquid outside inward. flow path, contami- element slowly removing smaller During backwash, station's flow from the inlet header to the drain the filter tube, dislodging media surface. The source fluids (internal back- source (external back- fluids used for cleaning drain header at the base of the unit. Once back- flow is reversed again and normal filtration resumes. Cake formation increases filtration Whereas the filtration media provides some of the filtration action, collected contaminants further increase efficiency. We cal this phenomenon "cake...

Open the catalog to page 2
Eaton Tubular Backwashing AFC AFR & F-Series Filters - 3

Permanent Media Backwash Cleaned Fabricated Construction Tubular Backwashing Filter AFC-Series When an application demands high-pressure operation – up to 1,000 psi (69 bar) – and scalable flexibility, the Eaton AFC-Series is optimal. Systems are available in single, duo, and multiplex configurations. FEATURES/BENEFITS • Solids removal from 1 to 1,700 microns • Single system flow rates up to 3,000 gpm (681 m3/hr) • Broad selection of filter media materials and retentions suitable for a wide range of applications • Smooth pipe and nozzle connection transitions to avoid dead spots in the...

Open the catalog to page 3
Eaton Tubular Backwashing AFC AFR & F-Series Filters - 4

AFC-SeriesTubular Backwashing Filter Body Inlet/Outlet Size - in (mm) Total Volumetric Capacity - Model #'s Drain SizeE 'Available in Straight-Thru design only 2Consult media availability chart 'All high pressure units (250 psi and over) incorporate 2-way ball valves additional drain sizes for specific retentions and types available. 3TefIon gaskets limit pressure maximum to 80 psi (5.5 bar) 5Duo configuration 350,740 and 1000 psi available in Straight-Thru design only. BConsult factory for optiona Body Inlet/Outlet Size - in (mm) Air Requirement (Automated Units) 60-120 psi (4.1-8.3 bar) @...

Open the catalog to page 4
Eaton Tubular Backwashing AFC AFR & F-Series Filters - 5

Permanent Media Backwash Cleaned Fabricated Construction Tubular Backwashing Filter F-Series For liquid filtering that requires unattended operation, maximum uptime, and solids removal from 1 to 1,700 microns, the Eaton F-Series delivers unbeatable performance. FEATURES/BENEFITS • Solids removal from 1 to 1,700 microns • Single system flow rates up to 3,000 gpm (681 m3/hr) • Smooth pipe and nozzle connection transitions to avoid dead spots in the fluid stream and minimize pressure drop • Broad selection of filter media materials and retentions suitable for a wide range of applications •...

Open the catalog to page 5
Eaton Tubular Backwashing AFC AFR & F-Series Filters - 6

F-SeriesTubular Backwashing Filter Body Inlet/Outlet Size - in (mm) 350 (177) system maximum (determined by screen material and elastomer seals) Air Requirement-auto units - psi (bar) 60 - 120 (4.1-8.3) @ 5 cfm, for sequencing Electrical Requirement - Backwash minimum flow 90 gpm (340 l/min) for single and Tri-Cluster media;150 gpm (567 l/min) for ACCUFLUX™ media 'Drain header size 3" (76.2). Consult factory for custom sizes 2Consult media availability chart for specific retentions and types available Teflon gaskets limit pressure maximum to 80 psi (5.5 bar). ASME code units are limited to...

Open the catalog to page 6
Eaton Tubular Backwashing AFC AFR & F-Series Filters - 7

Permanent Media Backwash Cleaned Fabricated Construction Tubular Backwashing Filter AFR-Series The revolutionary Eaton AFR-Series delivers high-flow filtration of water-like liquids at retentions as low as 1 micron in a compact one-square-meter footprint. FEATURES/BENEFITS • Solids removal from 1 to 1,700 microns • Flow rates up to 2,000 gpm (454 m3/hr) • Broad selection of filter media materials and retentions suitable for a wide range of applications • Numerous automated backwash options for operator-free service and minimal backwash effluent (<2% of system volume) • Smooth pipe and...

Open the catalog to page 7

All Eaton Filtration Solutions catalogs and technical brochures

  1. ZIPMATE™

    3 Pages

  2. LOFCLEAN™

    2 Pages

  3. LOFSORB™

    2 Pages

  4. LOFMET™

    2 Pages

  5. BECO® MAX2

    2 Pages

  6. DURAGAF

    2 Pages

  7. DCF 2000

    16 Pages

  8. TYPE 31L-ST

    2 Pages

  9. TYPE DTL DRY

    2 Pages

  10. Y-Strainers

    2 Pages

  11. SIDELINE

    2 Pages

  12. POLYLINE

    2 Pages

  13. MAXILINE

    2 Pages

  14. FLOWLINE

    2 Pages

  15. ECOLINE

    2 Pages

  16. DUOLINE

    2 Pages

  17. UNIBAG

    2 Pages

  18. SNAP RING

    1 Pages

  19. SENTINEL

    1 Pages

  20. LOFCLEAR

    2 Pages

Archived catalogs