Catalog excerpts
VCP-WXC Vacuum circuit breakers Xtra capabilities and enhanced features Features • The VCP-WXC, Eaton’s medium voltage ANSI breaker platform’s newest addition, features Xtra capability to meet today’s circuit protection needs. 15 kV, 63 kA, 1200–3000A drawout vacuum circuit breaker 62% DC Component that exceeds IEEE® requirements and is used in applications with high impedance/ resistance ratios (X/R) 175 kA peak close and latch and momentary rating exceeds IEEE preferred rating of 164 kA Demonstrated Out-of-Phase switching rating of 31.5 kA rms for industry applications such as power plants Additional vacuum interrupter very fast TRV testing up to 10 kV per microsecond Enhanced vacuum interrupter low frequency testing as low as 4 Hz for use with adjustable frequency drives Available as drawout with the option of six wheel roll-on-the-floor configuration Control circuit and wiring enhancements • Dedicated dry contact for spring-charged indication; this extra contact can be wired out to the panel for visual indication that the breaker is charged Enhanced wiring with a newly detailed wiring schematic Superior environmental capability, anti-radiation wire for special applications such as power plant use Control wiring terminated with ring terminals for reliable connections Application The VCP-WXC is ideal for large power plant and industrial applications where the highest interrupting and momentary ratings are required for distribution circuits. The VCP-WXC complements the VCP-WG generator circuit breakers for applications when very high inductance provides challenges to sys
Open the catalog to page 1VCP-WXC ratings (symmetrical current basis) Insulation Level Voltage Withstand Test Maximum Voltage Voltage Range Factor 95 kV peak 95 kV peak 95 kV peak A This breaker is available with 125 Vdc secondary control voltage. This includes as standard a motor, closing coil, shunt trip #1 and shunt trip #2. Short-Circuit Current Symmetrical Interrupting at V (Isc) Closing and Latching Capability Maximum Permissible Tripping Delay Transient Recovery Voltage (RRRV) C A Except as noted. B Three cycles. C Contact Eaton for higher RRRV or for more information. Capacitor Switching Ratings General...
Open the catalog to page 2All Eaton Count Control Products catalogs and technical brochures
-
COOPER POWER SERIES
20 Pages
-
Electrical enclosures
544 Pages
-
Climate Control Products
34 Pages
-
Eaton pilot devices
2 Pages
-
C22 Pilot Devices
4 Pages
-
Marina Power & RV Park Equipment
48 Pages
-
NEMA Contactors and Starters
154 Pages
-
IEC Contactors and Starters
259 Pages
-
Control Relays and Timers
204 Pages
-
Motor Protection and Monitoring
144 Pages
-
PowerXL DE1 Catalog
6 Pages
-
Expulsion Fuses
72 Pages
-
Pushbuttons and Indicating Lights
361 Pages
-
Power Pedestals
90 Pages
-
Loadcenters and Circuit Breakers
100 Pages
-
Series GJ
8 Pages
-
Series CD-CE-CF
10 Pages
-
Series GH
8 Pages
-
SAF Drives
1 Pages
-
SmartWire-DT
2 Pages
-
Cutler-Hammer
12 Pages
-
BladeUPS (12-60 kW)
12 Pages
-
9PX (5-11 kVA)
4 Pages
-
5S (500-1500 VA)
2 Pages
-
5P Tower (750-3000 VA)
2 Pages
-
5P Rackmount (500-3000 VA)
2 Pages
-
3S (350-750 VA)
2 Pages
-
Alternate Enclosures
4 Pages
-
Manual Motor Control
10 Pages
-
Multi-Pak Group Control
13 Pages
-
HVAC Control
10 Pages
-
Pump Panels
29 Pages
-
Reduced Voltage Starters
83 Pages
-
Lighting Contactors
16 Pages
-
NEMA Contactors and Starters
80 Pages
-
Volume 04 - Circuit Protection
684 Pages
-
Molded Case Circuit Breakers
432 Pages
-
Metering Products
151 Pages
-
Solutions Energy Savings
8 Pages
-
Counters, Timers and Tachometers
145 Pages
Archived catalogs
-
IEC Contactors and Starters
251 Pages