Series GH - 1

Circuit Breakers Economical EH-Frame rated at 0.5-100A

Open the catalog to page 1
Series GH - 2

Heinemann Circuit Breakers Series GH_I The EH-Frame breaker with hydraulic-magnetic dependability at competitive prices Now you can afford a completely magnetic 'hree-pole branch circuit protector tor less than you used lo soend lor a thermal unit Heinemann" breakers have proved their abiity by performing in "hardship" installations, indoor and out. that require a compact, environmentally stable breaker rated lo 100 amperes al 480 V ac Because of iheir ability to furnish both close-raled locked-rator protec- tion and running overcutreni protection without derating, even under extreme and...

Open the catalog to page 2
Series GH - 3

inn Circuit Breakers Serie; Electrical ratings Standard maximum voltage: Breakers may be used at any 50/60 Hz voltage up to and including 480 V. All breakers will be labeled with the standard voltage unless otherwise specified. (All UL/CSA-listed models must be labeled with the standard maximum voltage of 480 Vac) Consult factory for DC breakers rated 250 VDC Series up to 700 VDC at Standard current ratings: 15,20,25, 30,40,50,60,70, 80,90 and Special current ratings: Any integral or fractional current rating from 0.5 to 100 A ac. (Ratings below 15 A are not UIVCSA listed.) Interrupting...

Open the catalog to page 3
Series GH - 4

Heinemann Circuit Breakers Series GH_ The curves shown indicate the magnitude and duration of overloads which will be tolerated before tripping occurs. By selecting the proper curve, breaker response can be closely matched to the safe operating limits of the equipment or circuitry. Curve 1 allows the largest and most prolonged overload, needed to prevent nuisance tripping on motor circuits. Curve 2 a medium delay, accommodates mixed loads consisting of lights, motors, and resistive heating, where the breaker is rated to the wiring instead of to any specific load. Curve 3 permitting a very...

Open the catalog to page 4
Series GH - 5

etiemann Circuit Breakers Series GH_ PERCENT LOAD Pgrceul«{rated current w. trip dtiay at 28* C Delay Majrimuni (seconds) no trip 500 110 Delay Mintnwn (ttCMds) no trip 80 22 Percent of rated current vs. trip delay at 25* C Percent et rated current vs. trip delay at 25" C Delay Staimtim (seconds) no trip 6.4 Delay Minimum (seconds) no trip 0,70 Percent st rated current vs. trip delay at 26» C 0.11 0.097 Delay Maximum (seconds) no trip 60 0.022 0.021 Delay Minimum (seconds) no trip 8 Operating Temperature Range: -40°C to +85°C. Fungus and moisture resistance is provided in accordance with...

Open the catalog to page 5
Series GH - 6

Hstaiiftaiffl Circuit Breakers Note: Standard catalog number must have 18 digits including dashes. See How to Order non-standard when all poles of a multipole unit are not Series prefix(GH3) include a dash as shown. Terminal Location Add a dash before the code letter. I/A Std. 25x App. Internal Circuit Construction Notes 0 No Switch only (no coil) 2 9 Yes "Series trip with SPDT aux. switch 1,2,3 * On multipole units one aux. switch is supplied. It is located in the left pole when viewed from the front of the breaker. See page 7 for non-standard part number when additional switches or pole...

Open the catalog to page 6
Series GH - 7

Heinemann Circuit Breakers Series GH Series GH circuit breakers •Non-standard part numbers may require a factory assigned pan numbe;. Series prefix (6H) and number ol poles (1-3) Voltage. frequency and internal circuit for firs! pole on left as viewed Irom front of panel, or for all poles if identical, from Tables A and B. Code Frequency Terminal Location Type Approval Branch Circuit - General Purpose Branch Circuit - Special Purpose Manual Motor Controller Manual Motor Controller Breakers will be marked with the maximum UL approved voltage. DC breakers are not UL approved. Maximum voltage...

Open the catalog to page 7
Series GH - 8

Heinemann Circuit Breakers Series GH For the widest selection of circuit protection, from 0.01 to 700 amperes, look to Heinemann. SenwC (Frame ■■ rflv tilt * lw ■"; B'fdtf' Series GJ Hian Cuiera MjgrtelicCitcuil Breaker Series GUP HiQn CurrenlOC Hyflraa'K/MigneM BfeaiF MagneM Circul Sea!*d HydnyHc/ Magtwtc Breafcf' Cotripact rtpnaule/ Macflenc Prelector Mirjneue Ctfcuii For twvff tf«ornaiion. K* CMCO MMB CC7 0. PrMud! ffi-wwa (Ms CiUlag arr> crweiM i» en* or more Untied Sales ol America Merits am aoDronniis fDnMori «erfls inert »D«cole

Open the catalog to page 8