Explosion protected switchgear GRP and Stainless steel enclosures for harsh environments

Open the catalog to page 1
GHG 981 / GHG 982 Ex-Safety switch for zone 22 - 2

Safety first Occupational safety always has top priority! For this reason, whenever it is necessary to carry out maintenance, cleaning or repair work, it must be possible to isolate machines and installations from the electrical power supply in an absolutely safe and reliable way. Normally this is realised by switch-disconnectors (safety-switches) according to IEC/EN 62626-1. The GHG 981 / GHG982 safety switches approved for use in zone 22 areas containing explosive dust fulfils all these requirement. With the built-in padlocking facilities, they can be used as a load break switch with full...

Open the catalog to page 2
GHG 981 / GHG 982 Ex-Safety switch for zone 22 - 3

GHG 981... / GHG 982... - Ex-safety switches zone 22 The right size for every application The switches are available in 3-pole, 4-pole, and 6-pole versions in sizes ranging from 25 A to 400 A. From the 500 A onwards switches are available in 3-pole or 4-pole versions. All sizes from 25 A through 700 A feature full AC3 switching capacity for squirrel- cage motors during starting or while running per EN 60947-3 Appendix A. This is the most typical industrial application for motors. Ready for harsh environments The enclosures for our safety switches are designed with IP66 environmental...

Open the catalog to page 3
GHG 981 / GHG 982 Ex-Safety switch for zone 22 - 4

Technical Data Marking to 2014/34/EU Type Examination Certificate Permissible ambient temperature IK-class according to EN 50102 Rated voltage Rated current Frequency Switch-disconnector for maintenance accd. to IEC 62262-1 Protection class Degree of protection accd. to EN 60529 Auxiliary contact Padlocking Enclosure colour GHG 981... / GHG 982... © II 3 D Ex tc IIIC T80°C Dc CCH 15 ATEX 1001 / Safety Switch 25 A: CCH 22 ATEX 1005 X / Switch disconnector 25 A: CCH 22 ATEX 1006 X -55 °C up to +40 °C/45 °C/50 °C/55 °C see instruction manual IK 9 =A 10 J up to 690 V see ordering information 50...

Open the catalog to page 4
GHG 981 / GHG 982 Ex-Safety switch for zone 22 - 5

GHG 981... / GHG 982... - Ex-safety switches zone 22 Ordering details GHG 981 25 A - 100 A Enclosure sizes: GRP Enclosure sizes: metall Rated Poles Enclosure material Cable entry Cable glands Size Size Size Size Size Size Size Size Order No.1) current (metal thread) (plastic) 1 234 123 4 GHG 982 (25 A) Safety Switches 25 A 3 pole GRP 25 A 3 pole GRP + internal earth plate + stud 25 A 6 pole GRP + internal earth plate + stud 25 A 3 pole 316L Stainless steel 25 A 6 pole 316L Stainless steel GHG 982 (25 A) Emergency Stop 25 A 3 pole GRP 25 A 3 pole GRP + internal earth plate + stud 25 A 6 pole...

Open the catalog to page 5
GHG 981 / GHG 982 Ex-Safety switch for zone 22 - 6

GHG 981... / GHG 982... - Ex-safety switches zone 22 Ordering details GHG 981 40 A - 160 A Enclosure sizes: GRP Enclosure sizes: metall Rated Poles Enclosure material Cable entry Cable glands Size Size Size Size Size Size Size Size Order No.1) current (metal thread) (plastic) 1 234 123 4 40 A 3 pole 316L stainless steel 40 A 4 pole 316L stainless steel 80 A 3 pole 316L stainless steel 80 A 4 pole 316L stainless steel 100 A 3 pole 316L stainless steel 100 A 4 pole 316L stainless steel GHG 981 (160 A) 160 A 3 pole 316L stainless steel 160 A 4 pole 316L stainless steel 160 A 6 pole 316L...

Open the catalog to page 6
GHG 981 / GHG 982 Ex-Safety switch for zone 22 - 7

GHG 981... / GHG 982... - Ex-safety switches zone 22 Enclosure sizes: GRP Enclosure sizes: metall Rated Poles Enclosure material Cable entry Cable glands Size Size Size Size Size Size Size Size Order No.1) current (metal thread) (plastic) 1 234 123 4 1) For an emergency stop switch (red handle/yellow back plate), change the 3rd to last digit from R*2** (standard version) to R*3** (emergency stop) Accessories Type Version Cable glands Plastic cable glands M20 up to M63 see: Main catalogue part 2 Metal cable glands ADE 1 F2 see: Main catalogue part 2

Open the catalog to page 7
GHG 981 / GHG 982 Ex-Safety switch for zone 22 - 8

Dimension drawing Size 1 stainless steel enclosure Size 2 stainless steel enclosure Size 3 stainless steel enclosure Size 4 stainless steel enclosure

Open the catalog to page 8
GHG 981 / GHG 982 Ex-Safety switch for zone 22 - 12

U.S. (Global Headquarters): Eaton's Crouse-Hinds Business 1201 Wolf Street Syracuse, NY 13208 (866) 764-5454 FAX: (315) 477-5179 FAX Orders Only: (866) 653-0640 CrouseCustomerCTR@Eaton.com For more information: If further assistance is required, please contact an authorized Eaton Distributor, Sales Office, or Customer Service Department. Australia Phone +61-2-8787-2777 Fax +61-2-9609-2342 crousehindsanz@eaton.com China Phone +86-21-2899-3600 Fax +86-21-2899-4055 ECHsales@eaton.com Great Britain Phone +44-247-630-89 30 Fax +44-247-630-10 27 sales5@eaton.com India Phone +91-124-4683888 Fax...

Open the catalog to page 12