1. Catalogs
  2. EAO France
  3. Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment

Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment

Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment
1 / 16 PagesView full catalog

Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment

Product catalog summary
Overview: The Series 17 indicator range is designed for raised applications and includes components from 6 mm to 22.5 mm. These indicators are compatible with other EAO series and are used in machinery, automation, panel building, and laboratory equipment.
Specifications: The Series 17 features LED indicators available in sizes of 6 mm, 8 mm, 14 mm, 16 mm, and 22 mm, each with specific operating voltage, current, and luminous intensity attributes.
Technical Data: Indicators have brass terminals for anode and cathode connections, with an operating voltage tolerance of +10% and a current tolerance of ±15%. The maximum panel thickness for mounting is 6 mm.
Product Variants: Multiple product variants are available with different LED colors (red, green, yellow, blue, white) and configurations (interior, exterior, superflat), each with a unique part number and weight.
Mounting and Accessories: Indicators come with retaining rings and fixing nuts, with specified mounting cut-outs for each size. Additional accessories and detailed drawings are available for customization.
Recommendations: For detailed product configurations and quotations, users are directed to the EAO website.
Technical Specifications: Detailed specifications include LED color, operating voltage, current, luminous intensity, and weight. Operating voltages are primarily 24 VDC, 28 VDC, and 230 VAC, with current ratings from 3 mA to 26 mA.
Mechanical and Electrical Characteristics: Indicators feature plug-in terminals of sizes 2.0 x 0.5 mm or 2.8 x 0.8 mm, not suitable for soldering. The tightening torque for terminals is 20 Ncm.
Optical Characteristics: Wavelengths for LED colors are provided, such as red (660 nm), green (565 nm), and blue (475 nm), including dual-color LEDs like red/green and red/yellow.
Environmental Conditions: Storage temperature range is -25 °C to +80 °C, and service temperature range is -20 °C to +60 °C. The protection degree is IP 40, with an option for IP 67 using a supplied gasket.
Approvals and Standards: Indicators have UL and VDE approvals, with specifications subject to change without notice.
Accessories and Mounting: Accessories include flat receptacles and insulation sleeves for different terminal sizes, with specified mounting tools and fixing nuts.
Component Layouts and Drawings: Schematic overviews and component layouts indicate common cathode and anode connections.
Additional Information: Connectors are specified as brass terminals for anode and brass tinned terminals for cathode, with a maximum panel thickness of 6 mm.
See more

Catalog excerpts

Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment-1

Market segments The Series 17 indicator range comprises 6 mm to 22.5 mm components which are especially suited for: The Series 17 incorporates the following function: The EAO Series 17 is especially suited for applications in the segments: Raised design The large variety of front designs facilitates combined use with other EAO series. Machinery and Automation Panel building Laboratory and measuring equipment Please refer to the EAO website to obtain detailed information regarding this series www.products.eao.com Configure a product to your exact needs and request a quotation.

 Open the catalog to page 1
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment-3

Raised design Indicator flush mount 8 mm 307

 Open the catalog to page 3
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment-4

Raised design Equipment consisting of (schematic overview) Retaining ring Fixing nut Product can differ from the current configuration. Dimensions [mm] Each Part Number listed below includes all the black components shown in the 3D-drawing. Additional Information • Connectors: Brass terminal = anode (+); brass tinned terminal = cathode (-) • Operating voltage tolerance +10 % • Operating current tolerance ±15 % Operating voltage Operation current Lumi. intensity Indicator 6 mm LED 3 mm, Front dimension Ø 7 mm 15 mA Metal satin-chrome, interior Indicator 6 mm LED 3 mm, Front dimension Ø 7 mm 24...

 Open the catalog to page 4
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment-5

Raised design Equipment consisting of (schematic overview) Product can differ from the current configuration. Protection tube Each Part Number listed below includes all the black components shown in the 3D-drawing. Retaining ring • Connectors: Brass terminal = anode (+); brass tinned terminal = cathode (-) Additional Information • Operating voltage tolerance +10 % • Operating current tolerance ±15 % Dimensions [mm] P1 = Plug-in terminal 2.8 x 0.8 mm, P5 = Plug-in terminal 2.0 x 0.5 mm Component layout Lumi. intensity Operation current Operating voltage Product attribute Indicator 8 mm LED 5 mm,...

 Open the catalog to page 5
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment-6

Component layout Lumi. intensity Operation current Operating voltage Raised design Product attribute Sunlight visibility, light reduction of around 25 % by use of AC Indicator 8 mm LED 5 mm, Front dimension Ø 9.5 mm Metal satin-chro- red me, interior yellow with protection tube Metal satin-chro- red me, interior green Metal blackchrome, interior Indicator 8 mm LED 5 mm, Front dimension Ø 9.5 mm Metal satin-chro- red me, exterior white with protection tube Metal satin-chro- red me, exterior yellow Sunlight visibility, light reduction of around 25 % by use of AC Metal satin-chro- red me, exterior...

 Open the catalog to page 6
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment-7

Raised design Indicator flush mount 8 mm LED 5 mm, IP 40 Equipment consisting of (schematic overview) Each Part Number listed below includes all the black components shown in the 3D-drawing. 14 Dimensions [mm] P1 = Plug-in terminal 2.8 x 0.8 mm, P5 = Plug-in terminal 2.0 x 0.5 mm Product can differ from the current configuration. Additional Information • Connectors: Brass terminal = anode (+); brass tinned terminal = cathode (-) • Operating voltage tolerance +10 % • Operating current tolerance ±15 % Operating voltage Operation current • Operation modes (tri-colour LED): Red, green or yellow....

 Open the catalog to page 7
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment-8

Raised design Equipment consisting of (schematic overview) Protection tube Retaining ring Fixing nut Product can differ from the current configuration. Dimensions [mm] Each Part Number listed below includes all the black components shown in the 3D-drawing. Additional Information • Connectors: Brass terminal = anode (+); brass tinned terminal = cathode (-) • Operating voltage tolerance +10 % • Operating current tolerance ±15 % Lumi. intensity Component layout Operation current Operating voltage Product attribute Indicator 14 mm, LED 10 mm, Front dimension Ø 16 mm Metal satinchrome Metal blackchrome...

 Open the catalog to page 8
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment-9

Lumi. intensity Component layout Operation current Operating voltage Product attribute Raised design with protection tube Indicator 14 mm, LED 10 mm, Front dimension Ø 16 mm Metal satinchrome The component layouts you will find from page 315

 Open the catalog to page 9
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment-10

Raised design Protection tube Fixing nut Each Part Number listed below includes all the black components shown in the 3D-drawing. Product can differ from the current configuration. 6 Equipment consisting of (schematic overview) Dimensions [mm] Additional Information • Connectors: Brass terminal = anode (+); brass tinned terminal = cathode (-) • Maximum panel thickness 6 mm • Operating voltage tolerance +10 % • Operating current tolerance ±15 % Product attribute Lumi. intensity Operation current Operating voltage Indicator 16 mm LED 10 mm, Front dimension Ø 18.3 mm flat Pastic black with protection...

 Open the catalog to page 10
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment-11

Lumi. intensity Operation current Operating voltage Product attribute Raised design Indicator 16 mm LED 10 mm, Front dimension Ø 18.3 mm Pastic black Pastic black with protection tube Indicator 16 mm LED 10 mm, Front dimension Ø 18.3 mm Pastic black 28 VDC with protection tube Pastic black

 Open the catalog to page 11
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment-12

Raised design Equipment consisting of (schematic overview) Protection tube Retaining ring Fixing nut Product can differ from the current configuration. Dimensions [mm] Each Part Number listed below includes all the black components shown in the 3D-drawing. Additional Information • Connectors: Brass terminal = anode (+); brass tinned terminal = cathode (-) • Maximum panel thickness 6 mm • Operating voltage tolerance +10 % • Operating current tolerance ±15 % Component layout Operation current Operating voltage Product attribute Lumi. intensity Indicator 22mm LED 15 mm, Front dimension Ø 25 mm Metal...

 Open the catalog to page 12
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment-13

Flat receptacle Product attribute Flat receptacle Flat receptacle Product attribute Insulation sleeve Insulation sleeve

 Open the catalog to page 13
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment-14

Mounting tool Mounting tool Mounting tool for fixing nut long Part No. 19-991

 Open the catalog to page 14
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment-15

– common cathode – common cathode common cathode

 Open the catalog to page 15
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment-16

Technical data Technical Data Material Environmental conditions Actuator Reflector: Brass satin chrome/black chrome for indicator 16 mm dia. in black plastic The plastic (polycarbonate) is limited resistant against chemicals Mechanical characteristics Terminals Plug-in terminal 2.0 x 0.5 mm or 2.8 x 0.8 mm The indicators with tab-connection are not qualified for soldering Protection degree front IP 40 IP 67 as per DIN EN 60529 - Gap between LED and reflector and gap between reflector and frontplate sealed to IP 67 when using the supplied gasket Electrical characteristics Polarity Anode (+) Brass...

 Open the catalog to page 16

All EAO France catalogs and technical brochures

  1. BR45

    16  Pages

  2. data Series 45

    16  Pages

  3. data Series 04

    13  Pages

  4. Série 45

    134  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.