Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment
16Pages

{{requestButtons}}

Catalog excerpts

Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment - 1

Market segments The Series 17 indicator range comprises 6 mm to 22.5 mm components which are especially suited for: The Series 17 incorporates the following function: The EAO Series 17 is especially suited for applications in the segments: Raised design The large variety of front designs facilitates combined use with other EAO series. Machinery and Automation Panel building Laboratory and measuring equipment Please refer to the EAO website to obtain detailed information regarding this series www.products.eao.com Configure a product to your exact needs and request a quotation.

Open the catalog to page 1
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment - 3

Raised design Indicator flush mount 8 mm 307

Open the catalog to page 3
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment - 4

Raised design Equipment consisting of (schematic overview) Retaining ring Fixing nut Product can differ from the current configuration. Dimensions [mm] Each Part Number listed below includes all the black components shown in the 3D-drawing. Additional Information • Connectors: Brass terminal = anode (+); brass tinned terminal = cathode (-) • Operating voltage tolerance +10 % • Operating current tolerance ±15 % Operating voltage Operation current Lumi. intensity Indicator 6 mm LED 3 mm, Front dimension Ø 7 mm 15 mA Metal satin-chrome, interior Indicator 6 mm LED 3 mm, Front dimension Ø 7 mm...

Open the catalog to page 4
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment - 5

Raised design Equipment consisting of (schematic overview) Product can differ from the current configuration. Protection tube Each Part Number listed below includes all the black components shown in the 3D-drawing. Retaining ring • Connectors: Brass terminal = anode (+); brass tinned terminal = cathode (-) Additional Information • Operating voltage tolerance +10 % • Operating current tolerance ±15 % Dimensions [mm] P1 = Plug-in terminal 2.8 x 0.8 mm, P5 = Plug-in terminal 2.0 x 0.5 mm Component layout Lumi. intensity Operation current Operating voltage Product attribute Indicator 8 mm LED 5...

Open the catalog to page 5
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment - 6

Component layout Lumi. intensity Operation current Operating voltage Raised design Product attribute Sunlight visibility, light reduction of around 25 % by use of AC Indicator 8 mm LED 5 mm, Front dimension Ø 9.5 mm Metal satin-chro- red me, interior yellow with protection tube Metal satin-chro- red me, interior green Metal blackchrome, interior Indicator 8 mm LED 5 mm, Front dimension Ø 9.5 mm Metal satin-chro- red me, exterior white with protection tube Metal satin-chro- red me, exterior yellow Sunlight visibility, light reduction of around 25 % by use of AC Metal satin-chro- red me,...

Open the catalog to page 6
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment - 7

Raised design Indicator flush mount 8 mm LED 5 mm, IP 40 Equipment consisting of (schematic overview) Each Part Number listed below includes all the black components shown in the 3D-drawing. 14 Dimensions [mm] P1 = Plug-in terminal 2.8 x 0.8 mm, P5 = Plug-in terminal 2.0 x 0.5 mm Product can differ from the current configuration. Additional Information • Connectors: Brass terminal = anode (+); brass tinned terminal = cathode (-) • Operating voltage tolerance +10 % • Operating current tolerance ±15 % Operating voltage Operation current • Operation modes (tri-colour LED): Red, green or...

Open the catalog to page 7
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment - 8

Raised design Equipment consisting of (schematic overview) Protection tube Retaining ring Fixing nut Product can differ from the current configuration. Dimensions [mm] Each Part Number listed below includes all the black components shown in the 3D-drawing. Additional Information • Connectors: Brass terminal = anode (+); brass tinned terminal = cathode (-) • Operating voltage tolerance +10 % • Operating current tolerance ±15 % Lumi. intensity Component layout Operation current Operating voltage Product attribute Indicator 14 mm, LED 10 mm, Front dimension Ø 16 mm Metal satinchrome Metal...

Open the catalog to page 8
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment - 9

Lumi. intensity Component layout Operation current Operating voltage Product attribute Raised design with protection tube Indicator 14 mm, LED 10 mm, Front dimension Ø 16 mm Metal satinchrome The component layouts you will find from page 315

Open the catalog to page 9
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment - 10

Raised design Protection tube Fixing nut Each Part Number listed below includes all the black components shown in the 3D-drawing. Product can differ from the current configuration. 6 Equipment consisting of (schematic overview) Dimensions [mm] Additional Information • Connectors: Brass terminal = anode (+); brass tinned terminal = cathode (-) • Maximum panel thickness 6 mm • Operating voltage tolerance +10 % • Operating current tolerance ±15 % Product attribute Lumi. intensity Operation current Operating voltage Indicator 16 mm LED 10 mm, Front dimension Ø 18.3 mm flat Pastic black with...

Open the catalog to page 10
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment - 11

Lumi. intensity Operation current Operating voltage Product attribute Raised design Indicator 16 mm LED 10 mm, Front dimension Ø 18.3 mm Pastic black Pastic black with protection tube Indicator 16 mm LED 10 mm, Front dimension Ø 18.3 mm Pastic black 28 VDC with protection tube Pastic black

Open the catalog to page 11
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment - 12

Raised design Equipment consisting of (schematic overview) Protection tube Retaining ring Fixing nut Product can differ from the current configuration. Dimensions [mm] Each Part Number listed below includes all the black components shown in the 3D-drawing. Additional Information • Connectors: Brass terminal = anode (+); brass tinned terminal = cathode (-) • Maximum panel thickness 6 mm • Operating voltage tolerance +10 % • Operating current tolerance ±15 % Component layout Operation current Operating voltage Product attribute Lumi. intensity Indicator 22mm LED 15 mm, Front dimension Ø 25 mm...

Open the catalog to page 12
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment - 13

Flat receptacle Product attribute Flat receptacle Flat receptacle Product attribute Insulation sleeve Insulation sleeve

Open the catalog to page 13
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment - 14

Mounting tool Mounting tool Mounting tool for fixing nut long Part No. 19-991

Open the catalog to page 14
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment - 15

– common cathode – common cathode common cathode

Open the catalog to page 15
Series 17: Machinery and Automation, Panel building, Laboratory and measuring equipment - 16

Technical data Technical Data Material Environmental conditions Actuator Reflector: Brass satin chrome/black chrome for indicator 16 mm dia. in black plastic The plastic (polycarbonate) is limited resistant against chemicals Mechanical characteristics Terminals Plug-in terminal 2.0 x 0.5 mm or 2.8 x 0.8 mm The indicators with tab-connection are not qualified for soldering Protection degree front IP 40 IP 67 as per DIN EN 60529 - Gap between LED and reflector and gap between reflector and frontplate sealed to IP 67 when using the supplied gasket Electrical characteristics Polarity Anode (+)...