MIS-4000-series
3Pages

{{requestButtons}}

Catalog excerpts

MIS-4000-series - 1

To Order Call Toll Free: 1-877-805-3377 £ EAGLE EYE]MIS-4000 Modular Inverter SystemCommon Applications: Telecom, Datacom, Mass Transit, Oil & Gas, Utility MIS-4000 Inverter Systems IS-SERIES Product Description The MIS-4000 is a ready-made inverter package rated up to 75 kVA capacity and designed to provide a pure sine wave AC supply as a complement to any existing DC power solution. Compact, friendly Plug & Play installation, self-standing open relay rack ideal for low MTTR applications in power room. It can be used either to piggyback DC power sources or as fully integrated AC power center with built-in in and out protections. Thanks to TSI technology, it provides outstanding power conditioning and high-end availability. Product Features • Permanent AC to AC double conversion • Great disturbance rejection rate • Redundant AC & DC input sources • Source change over not visible by the load • Highly efficient energy conversion • Preserve battery life expectancy • Compact footprint • Offers space for AC distribution or integration with 3rd party equipment • Operates until 65°C (149°F) (de-rating may apply) • Can be provided with 120 VAC, 120/240 VAC and 120/208 VAC system configurations Extra Features TSI Technology - The TSI Enhanced Power Conversion mode develops a high-quality AC by drawing power simultaneously from the AC mains and DC sources and presents a regenerated AC for critical application. Since the system draws power from each source simultaneously, output power is guaranteed as long as one input source is available. Applicable Standards MTBF (Each Module) Efficiency (Typical): Enhanced Power Conversion / On Line Dielectric Strength DC/AC True Redundant Systems - Compliant Vibration Altitude Above Sea Ambient / Storage Temperature / Relative Humidity Operating Temperature Measured at Both Room and Inlet Levels Operating Ambiance / Ingress Protection Material (Casing) IEC 61000-4 / FCC part 15 / cULus 1778 Listed / RoHS 240,000 hrs 95% / 91% 4,300 VDC 3 disconnection levels on AC out and DC in power ports 4 disconnection levels on AC in port GR63 office vibration 0 to 100 Hz-0.1 g / transport vibration 5-100 Hz 0.5 g 100 to 500 Hz-1.5 g / Drop test < 1,500 m no derating > 1,500 m - 0.8 % derating per 100 m -40 - 70°C (-40 - 158°F) / 95 %, non-condensing -20 - 40°C (-4 - 104°F) for rated power 40 - 65°C with 2% /°C derating 104 - 149°F with 1% /°F derating Free from dust and corrosive materials / NEMA 1 2 Coated steel-ALU ZINC

Open the catalog to page 1
MIS-4000-series - 2

To Order Call Toll Free: DC Input Specifications Nominal Voltage (DC) / Voltage Range Voltage Ripple Input Voltage Boundaries AC Input Specifications Voltage Range (AC) (Full Power Rating) Brownout Range and Behavior 80 – 104 VAC use DC source contribution if need be (can be disabled) Conformity Range Before Transfer to DC Power Factor Frequency Range (Selectable) / Synchronization Range AC Output Specifications Full VA power rating from 0 inductive to 0 capacitive Limited to W power rating from Pf 0.8 to 1 Inverter Systems Admissible Load Power Factor Frequency / Frequency Accuracy Total...

Open the catalog to page 2
MIS-4000-series - 3

To Order Call Toll Free: Inverter Systems IS-SERIES

Open the catalog to page 3

All Eagle Eye Power Solutions catalogs and technical brochures

  1. SC-1000

    2 Pages

  2. SC-1500

    2 Pages

  3. SC-2000

    2 Pages

  4. RM-48-2K

    2 Pages

  5. RM-48-3K

    2 Pages

  6. RM-48-KA

    1 Pages

  7. MIS-1000

    3 Pages

  8. ENC-2000

    1 Pages

  9. BTM-Series

    1 Pages

  10. BQMS

    2 Pages

Archived catalogs

  1. HGD-3000

    1 Pages

  2. DC Load Bank

    3 Pages

  3. LB-1000

    1 Pages

  4. SCR-SCRF

    1 Pages

  5. SG-100M

    1 Pages

  6. SG-1000

    1 Pages

  7. SG-Ultra Max

    1 Pages