HGVS-1000 Hydrogen Gas Ventilation System
1Pages

{{requestButtons}}

Catalog excerpts

HGVS-1000 Hydrogen Gas Ventilation System - 1

To Order Call Toll Free: HGVS-1000 Hydrogen Gas Ventilation System Model # HGVS-1000 Product Overview Optional Features Compliance with IEEE Std 450 Compliance with National Fire Protection Agency (NFPA) Article 64 Compliance with Uniform Building Code (UBC) Section 6400 Automatic Operation and Continuous 24/7 Monitoring High Sensitivity and Stability Long Life-Span for Reliable Monitoring Inexpensive protection for equipment and personnel Two-Year Warranty Fan Supply Power: 24vdc, 48vdc, or 115 VAC Fan can be provided as an exhaust fan (standard) or supply fan (optional) Fan can be provided for -48 VDC A&B isolated redundant power service Fan can be provided with an optional firefighter shut down lever Fan can be provided with an optional emergency horn & flashing light Technical Specifications Connections: Mounting: Positive Shut-Off: Dimensions: Weight: Safety Standard: Options: Ventilation Systems The system has four fans factory-rated at 850 CFM each. This conforms to N+1 for 2550 CFM. The vent is equipped with a “Positive Airflow Shut Off” feature. These doors can be closed by an external electric command, and will stop any airflow from passing through the fans. The HGVS-1000 is primarily set up to exhaust air but can be reversed to source forced air into a room. The HGVS-1000 Hydrogen Gas Ventilation System is a forced ventilation fan system used in battery charging rooms and other areas where hydrogen may be present. This is to be used in conjunction with the HGD-2000 and HGD-3000 Hydrogen Gas Detectors. The hydrogen gas detector is mounted in the highest part of the room and the HGVS-1000 vent fan is mounted through the outside wall. Input: Positive shutoff control, N.O. Dry Contacts Output: 1% Fan Running, 2% Alarm, N.O. Dry Contacts Dry contact activated, manually reset H x W x D: 610 x 610 x 450 mm (24 x 24 x 18 in) Fan: 23 kg (51 lbs) Rain Shield & Damper: 10.9 kg (24 lbs) (4) fans rated at 850 CFM Total 3400 CFM N+1 (3) Fans at 850 CFM Total 2550 CFM for 777 sq. m (2550 sq. ft) Mounting wing placement, room exhaust source, small or large rain shield, N.O. to N.C., custom features on request Utilities and Power Plants UPS Power Systems Fuel Cell Test Stations Nuclear Waste Reforming Hydrogen Refueling Stations Fire Department Battery Suppliers Battery Charging Rooms Motive Power Golf Cart Description Hydrogen Gas Ventilation System (used in conjunction with HGD-2000 and HGD-3000)

Open the catalog to page 1

All Eagle Eye Power Solutions catalogs and technical brochures

  1. SC-1000

    2 Pages

  2. SC-1500

    2 Pages

  3. SC-2000

    2 Pages

  4. RM-48-2K

    2 Pages

  5. RM-48-3K

    2 Pages

  6. RM-48-KA

    1 Pages

  7. MIS-1000

    3 Pages

  8. ENC-2000

    1 Pages

  9. BTM-Series

    1 Pages

  10. BQMS

    2 Pages

Archived catalogs

  1. HGD-3000

    1 Pages

  2. DC Load Bank

    3 Pages

  3. LB-1000

    1 Pages

  4. SCR-SCRF

    1 Pages

  5. SG-100M

    1 Pages

  6. SG-1000

    1 Pages

  7. SG-Ultra Max

    1 Pages