1. Catalogs
  2. Eagle Eye Power Solutions
  3. GD-3000 Combustible Gas Detector 2013 Catalog page
video corpo

GD-3000 Combustible Gas Detector 2013 Catalog page

GD-3000 Combustible Gas Detector 2013 Catalog page

Product catalog summary
Product Overview: The GD-3000 is a versatile combustible gas detector designed for detecting methane, propane, or hydrogen gases. It features low-level detection capabilities and is factory calibrated for easy installation. The device is suitable for use in various environments such as battery rooms and parking garages, providing automatic feedback and fan control to reduce gas concentrations. It operates with 12VDC or 24VDC panels.
Features: The GD-3000 includes a selectable digital display, buzzer, and fan relay with adjustable run times. It is factory calibrated but can be field calibrated using specific gas regulators. The device mounts on a standard electrical box and includes a 5 A SPDT fan relay and a 0.5 A alarm relay. It is ETL listed to UL 61010-1 standards and can be used with fire panels.
Technical Specifications: The detector offers an accuracy of ±5% of the LEL reading up to 50% LEL. It features selectable alarm relay actuation and settings, with a current draw of 75 mA in alarm mode. The fan relay is rated at 5 A, 240 VAC, with selectable actuation levels. The operating environment ranges from -18 to 52 °C with 10-90% relative humidity. Power requirements are 3 W max from 12-24 VAC or 12-48 VDC.
Applications: The GD-3000 is suitable for use in utilities, power plants, UPS systems, diesel engines, construction facilities, fire departments, and battery suppliers.
See more

Catalog excerpts

GD-3000 Combustible Gas Detector 2013 Catalog page-1

To Order Call Toll Free: GD-3000 Combustible Gas Detector Model # GD-3000 Product Overview The GD-3000 combustible gas detector is a versatile, easy-to-use device that allows you to select between methane (NG), propane (LP), or hydrogen (H2) gas detection. The GD-3000 provides low-level detection of combustible gas in an easy-to-maintain monitor that is factory calibrated for simple installation. This low voltage gas detector provides automatic feedback and fan control that can help reduce combustible gas concentrations in battery rooms, parking garages, maintenance facilities, and other locations that require combustible gas detection. The unit can be used with 12VDC or 24VDC N.O. (fire/security) panels. Utilities and Power Plants UPS Power Systems Diesel and other IC Engines Construction and Maintenance Facilities Fire Department Battery Suppliers Motive Power Selectable (on/off) digital display, buzzer, fan relay (minutes), fan minimum run time Selectable fan and alarm relay activation Factory Calibrated - Can also be field calibrated using 10% LEL Methane, 10% LEL Propane or 10% LEL Hydrogen gas regulator and calibration hood One screw allows access for easy calibration Mounts on a standard 4” x 4” electrical box, no cover needed 5 A SPDT fan relay controls starters of exhaust fans 0.5 A.N.O. or N.C. alarm relay connects to warning devices or control panels Supervised system design: internal detector problem will cause the fan & alarm relay to activate ETL Listed to UL 61010-1 GD-3000 can be used with 12VDC or 24VDC N.O. (fire) panels GD-3000 dry contact fan relay can use panel power or fan power Match fan relay contacts to fan size, and coil voltage to power source Technical Specifications Accuracy: Alarm Relay: Alarm Relay Actuation: Alarm Relay Settings: Current @ 24VDC: Fan Relay: Fan Relay Actuation: Fan Delay Settings: ±5% of the LEL reading up to 50% LEL 0.5A 200 V, 10 VA Selectable N.O. default or N.C. OFF, 5, 10, 15, 20 (default), 25% LEL 75 mA in alarm (two relays), 50 mA (fan relay only) and 23 mA standby 5 A, 240 VAC, pilot duty, SPDT Selectable at 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 (default), 11, 12, 13, 14, 15, 16, 17, 18, 19, 20% LEL 0, 1, 3 (default), 5, 10 minutes Fan Minimum Run Time: Settings are OFF (default), 3, 5, 10, 15 minutes Current Loop: Operating Environment: Mounting & Connection Points Power Requirements: Dimensions / Weight: Description GD-3000 Combustible Gas Detector / Controller / Transducer www.eepowersolutions.com | p: +1-414-962-3377 | toll free: +1-877-805-3377 | fax: +1-414-962-3660

 Open the catalog to page 1

All Eagle Eye Power Solutions catalogs and technical brochures

  1. SC-1000

    2  Pages

  2. SC-1500

    2  Pages

  3. SC-2000

    2  Pages

  4. RM-48-2K

    2  Pages

  5. RM-48-3K

    2  Pages

  6. RM-48-KA

    1  Page

  7. MIS-1000

    3  Pages

  8. ENC-2000

    1  Page

  9. BTM-Series

    1  Page

  10. BQMS

    2  Pages

Archived catalogs

  1. SG-Ultra Max

    1  Page

  2. SG-1000

    1  Page

  3. SG-100M

    1  Page

  4. SCR-SCRF

    1  Page

  5. LB-1000

    1  Page

  6. DC Load Bank

    3  Pages

  7. HGD-3000

    1  Page

  8. DC SLB-Series

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.