Eagle Eye NERC PRC-005-2 Compliance Guide - 1

Keeping an Eye on Your Critical Power! NERC PRC-005-2 Compliance Guide Ensure Reliability of Critical Backup Power ☑ Internal/Connection ☑ Ground Fault Resistance Eagle Eye Power Solutions, LLC ☑ Temperature ☑ Load Testing

Open the catalog to page 1
Eagle Eye NERC PRC-005-2 Compliance Guide - 2

Keeping an Eye on Your Critical Power! NERC Battery Monitoring and Portable Testing Solutions NERC PRC-005-2 Compliance What is NERC? NERC (North American Electric Reliability Corporation) is a not-for-profit regulatory authority that ensures the reliability of the Bulk Power System in North America by enforcing Reliability Standards. PRC-005 is the standard for Protection Systems Maintenance and Testing. PRC005 continues to be the most commonly violated reliability standard in North America. NERC Standard PRC-005-2 requires utilities to document and implement programs for the maintenance...

Open the catalog to page 2
Eagle Eye NERC PRC-005-2 Compliance Guide - 3

BATTERY MONITORING IEEE NERC www.eepowersolutions.com

Open the catalog to page 3
Eagle Eye NERC PRC-005-2 Compliance Guide - 4

To Order Call Toll Free: Compliance Solutions NERC BATTERY MONITORING SOLUTION NERC PRC-005-2 -Table 1-4(f) “Exclusions for Protection System Station DC Supply Monitoring Devices and Systems” *Maximum Maintenance Interval: No periodic maintenance specified Eagle Eye NERC Battery Monitoring Solution Eagle Eye Power Solutions provides battery monitoring solutions to power utilities worldwide. NERC (North American Electric Reliability Corporation) is a not-for-profit regulatory authority that ensures the reliability of the BES by enforcing reliability standards. NERC PRC-005 is the...

Open the catalog to page 4
Eagle Eye NERC PRC-005-2 Compliance Guide - 5

BQMS Battery Monitoring System The BQMS Battery Monitoring System is a modular system that allows for complete monitoring of critical backup power systems. Parameters monitored include system voltage, load current, cell voltage, internal / connection resistance, cell temperature, & ambient temperature. The BQMS is designed for use on vented lead acid (VLA) and valve regulated lead acid (VLA). The included software package, Centroid 2, allows for remote viewing and data management of all connected Eagle Eye battery monitoring systems. Ordering Information ELM-Series Electrolyte Level Monitor...

Open the catalog to page 5
Eagle Eye NERC PRC-005-2 Compliance Guide - 6

Compliance Solutions NERC PORTABLE TESTING SOLUTION To Order Call Toll Free: Eagle Eye NERC Portable Testing Solutions Eagle Eye understands the importance of testing and maintaining batteries per NERC PRC-005-2 standards. We offer complete battery testing kits and options that meet and exceed these requirements. The purpose of NERC PRC-005 is to document and implement programs for the maintenance of all protection systems affecting the reliability of the Bulk Electric System (BES) so that these protection systems are kept in working order.

Open the catalog to page 6
Eagle Eye NERC PRC-005-2 Compliance Guide - 7

Ultra-Max Plus Kit The Ultra-Max Plus Kit is the premier kit for NERC compliance for Vented Lead Acid (VLA) and Nickel-Cadmium (NiCad) batteries. The Ultra-Max Plus kit has three parts: an IBEX-Ultra Portable Ohmic Battery Tester, SG-Ultra Max Digital Hydrometer, and Exmons Ultra+ Battery Management Software for all-in-one trending and reporting. The Ultra-Max Plus Kit tests internal resistance (internal ohmic values), voltage, inter-cell resistance (connection resistance), temperature, DC current, ripple current, specific gravity (state of charge), and electrolyte temperature. GFL-1000...

Open the catalog to page 7
Eagle Eye NERC PRC-005-2 Compliance Guide - 8

Critical Battery Monitoring, Testing, & Charging Solutions Battery Monitoring Portable Resistance Testing Digital Hydrometers SMART Load Testing Voltage & Ground Monitoring NERC Compliance Portable Testing NERC Compliance Monitoring Thermal Runaway Monitoring Electrolyte Level Monitoring Battery Regenerators Ground Fault Location Data-Logging Volt Meters Battery Charging phone: 1-414-962-3377 | toll-free: 1-877-805-3377 fax: 1-414-962-3660 info@eepowersolutions.com * The content of this information is subject to change without prior notice for the improvement of the product’s performance.

Open the catalog to page 8

All Eagle Eye Power Solutions catalogs and technical brochures

  1. SC-1000

    2 Pages

  2. SC-1500

    2 Pages

  3. SC-2000

    2 Pages

  4. RM-48-2K

    2 Pages

  5. RM-48-3K

    2 Pages

  6. RM-48-KA

    1 Pages

  7. MIS-1000

    3 Pages

  8. ENC-2000

    1 Pages

  9. BTM-Series

    1 Pages

  10. BQMS

    2 Pages

Archived catalogs

  1. HGD-3000

    1 Pages

  2. DC Load Bank

    3 Pages

  3. LB-1000

    1 Pages

  4. SCR-SCRF

    1 Pages

  5. SG-100M

    1 Pages

  6. SG-1000

    1 Pages

  7. SG-Ultra Max

    1 Pages