D2xC1X05
3Pages

{{requestButtons}}

Catalog excerpts

D2xC1X05 - 1

1-34-020 / Non-sparking signals D2xC1X05 Alarm Horn Sounder & Xenon Strobe Beacon The D2xC1X05 features a high output, 116dB(A) alarm horn sounder combined with a 5 Joule Xenon strobe beacon. Low current consumption and high SPL in a robust Type 4/4X, IP66 enclosure ensure the D2xC1X05 is suitable for all haz loc fire alarm system and general signalling applications. The corrosion proof, marine grade aluminium die cast enclosure is phosphated and powder coated providing resilience in the harshest of hazardous location environments. One device, globally certified: ATEX, IECExZone 2 & 22; NEC/CEC CI D2 and CII D2; NEC CI Zone 2 and Zone 22; CEC Zone 2 & 22 and CII D2. UL & cUL approved 24Vdc version for fire alarm use. Features • 5 Joule Xenon beacon with 116dB(A) alarm horn • 64 alarm tones, 4 remotely selectable alarm stages/channels • Automatic synchronisation on multi-sounder system • Field changeable lens colours Approvals • UL File ref: E230764 ANSI/ISA 12.12.01 - 2013 CSA C22.2 No. 213-M1987 ANSI/UL6007 9-0-13 ANSI/UL60079-15-2013 ISA60079-31-2009 CAN/CSA C22.2 No. 60079-0-11 CAN/CSA C22.2 No. 60079-15-12 CAN/CSA C22.2 No. 60079-31-12 • IECEx cert: IECEx ULD 14.0004X IEC60079-0: ed. 6.0 (2011-06) IEC60079-15: ed. 4.0 (2010-01) IEC60031-31: ed. 2.0 (2013-11) • ATEX cert: DEMKO 14 ATEX 4786493904X EN60079-0:2012 EN6007 9-15:2010 EN60079-31:2009 Coding • NEC / CEC: Class I Div 2 ABCD T2B Ta -40°C to +70°C Class I Div 2 ABCD T2C Ta -40°C to +55°C Class I Div 2 ABCD T2D Ta -40°C to +40°C Class II Div 2 FG T5 Ta -40°C to +50°C Class III Div 1&2 Ta -40°C to +50°C • NEC: Class I Zone 2 AEx nA IIC T2 Gc (Ta -40°C to +50°C) Zone 22 AEx tc IIIC 120°C Dc (Ta -40°C to +50°C) • CEC: Class I Zone 2 Ex nA IIC T2B Gc X (Ta -40°C to +50°C) Class I Zone 2 Ex nA IIC T2C Gc X (Ta -40°C to +45°C) Zone 22 Ex tc IIIC 120°C Dc (Ta -40°C to +50°C) Class II Div 2 EFG T4A Ta -40°C to +50°C • IECEx & ATEX: II 3G Ex nA IIC T2 Gc (Ta -40°C to +50°C) II 3D Ex tc IIIC 90°C Dc (Ta -40°C to +50°C) warning signals

Open the catalog to page 1
D2xC1X05 - 2

10ft/3m] No. of tones: 64 (UKOOA / PFEER compliant) Volume control: Adjustable -12dB(A) [Tone 2] Stage switching: DC units - Positive or Negative line. AC units - common supply line Strobe Beacon: Part Codes Version: Part code: Product type: D2xC1X05 Haz Loc alarm horn sounder & Xenon strobe beacon 24V dc - UL/cUL Fire Alarm 48V dc 115V ac 2 30V ac Cable Entry Type: [e] A B C D E F G Note: Peak Candela: 500,000 cd - calculated from energy (J) Effective Intensity 250 cd - calculated from energy (J) cd: Peak Candela: 33,410 cd - measured ref. to I.E.S. Effective...

Open the catalog to page 2
D2xC1X05 - 3

No liability is accepted for any consequence of the use of this document. The technical specification of this unit is subject to change without notice due to our policy of continual prod uct developnent. All dinensions are approxinate. This unit is sold subject to our standard conditions of sale, a copy of which is available on request.

Open the catalog to page 3

All E2S Warning Signals catalogs and technical brochures

  1. D1x

    2 Pages

Archived catalogs

  1. issue S15a