video corpo

Thermal Circuit Breaker 1115-...
2Pages

{{requestButtons}}

Catalog excerpts

Thermal Circuit Breaker 1115-... - 1

Thermal Circuit Breaker 1115-... Description Single pole thermal reset circuit breaker l Space-saving, slim design l Ease of installation through snap-in frame l Reliable, trip-free mechanism l Approvals: UL1077, EN60934 l Attractively low price Typical applications Power supply units, UPS equipment, battery chargers, oxygen treatment devices, office machines 1115 Order numbering code Rated voltage Current rating range Typical life 500 operations at 1.5 times rated current, resistive load, AC 125 V 50 operations at 2 times rated current, inductive load, AC 250 V Rupture capacity UL1077 EN 60934 Ambient temperature Vibration Approvals Approval authority Rated voltage Current rating range 1...16 A Technical Data Type No. 1115 single pole thermal circuit breaker Mounting method F1 snap-in mounting Number of poles 1 1 pole, thermally protected Accessories, style 1 black push button Terminals P1 blade terminals A 6.3 x 0.8 mm Characteristic curve T1 thermal 3...16 A T2 thermal 1...2.5 A Current ratings 1...16A Approval mark 1.000 A (C, 1), AC 250 V 200 A (C, 1), DC 32 V 500 A (INC1), AC 250 V -20°C … + 60°C 57 Hz acceleration 30m/s2 (3g) in X, Y, Z directions (twice/min.) 300m/s2 (30g) in X, Y, Z directions approx. 8g Current ratings and typical voltage drop Cut-out dimensions Current rating range (A) 8 Current rating Voltage drop range (A) (mV) 1 < 1000

Open the catalog to page 1
Thermal Circuit Breaker 1115-... - 2

Thermal Circuit Breaker 1115-... Dimensions Time/current characteristics No trip 100% must trip 135% Trip time in seconds … times rated current No trip 100% must trip 150% Trip time in seconds ±IT13 to DIN ISO 286 applies to nominal dimensions without tolerances Schematic diagram … times rated current The time/current characteristic depends on the ambient temperature. In order to eliminate nuisance tripping, please multiply the current rating by a derating factor (see chapter Technical Information) ambient temperature [°C] Temperature factor All dimensions without tolerances are for...

Open the catalog to page 2

All E-T-A catalogs and technical brochures

  1. MPR10, MPR20

    5 Pages

  2. CATALOGUE

    108 Pages

  3. CPC20

    12 Pages

  4. CPC12

    8 Pages

  5. REX12

    16 Pages

  6. PC10IO

    2 Pages

  7. PC10PN

    4 Pages

  8. PC10PB

    4 Pages

  9. SVS18

    6 Pages

  10. 1140-E

    4 Pages

  11. 1110

    2 Pages

  12. 129-L11-H-KF

    2 Pages

  13. 127

    4 Pages

  14. 104

    4 Pages