HMK PowerPlex Power Module PP-M-DC024 PowerPlex is a CAN based system for connecting and controlling electrical loads, and for monitoring and transmitting sensor data and commands. The system is especially suited to recreational and work boats as well as other specialised vehicle applications. PowerPlex is freely configurable by means of easy-to-use PC software, is maintenance free and protected against harmful environmental influences. PowerPlex installations comprise decentralised intelligent Panel and Power modules which greatly reduce conventional wiring and provide a very wide range of additional functionality possibilities. A total of up to 30 modules of the two types can be combined into a single installation for the transmission and processing of command signals and data. Each module is connected to the system's DC power source. PowerPlex incorporates a manual override feature for each 8 A and 25 A load output to ensure additional security for safety-critical systems. Typical applications Watercraft, e. g. recreational and work boats, special vehicles • redundant protection - Four Level Protection Concept (FLPC) • programmable overload protection • simple configuration • Windows based configuration software • integral diagnostic and monitoring functions • wire break detection • inputs for analogue sensors • eight channel dimming function (8 A + 25 A outputs) Ordering information Housing colour_ User installation manual enclosed Circuit Labels_ Authority Voltage ratings Technical data Max. total current per module 102 A Degree of Protection IP22 in a vertical mounting position with the main power connectors downwards Operating temperature range -40...+85 °C (-40...+185 °F)_ Storage temperature range -40...+85 °C (-40...+185 °F)_ Humid heat Vibration sinusoidal (EMC directive, CE logo) emission: EN 61000-6-3 8 inputs for switches or momentary switches analogue input: Rin: 40 kQ; resolution: 10 bit 6 outputs with 8 A max. continuous current load output: Power MOSFET, high side switching adjustable from 1 A to 8 A in 1 A steps dimmable in 10 steps with 100 Hz PWM typical voltage drop U0N overload tripping range: 1.01 ...1.30 x lN trip time: adjustable from 100 msec to 6 s current limitation: typically 60 A at DC 24 V leakage current wire breakage monitoring of load: wire breakage tresholds: OFF condition: RLoad: typically > 5 kQ ON condition: lLoad typically < 200 mA additional overload protection by means of one E-T-A circuit breaker type 1610-21 -10 A per output Comliant with IEC 60533 Electrical and electronic installations in Ships - Electromagnetic compatibility
Open the catalog to page 1HWK PowerPlex Power Module PP-M-DC024 Technical data 2 outputs with 25 A max. continuous current load output Power MOSFET, high side switching adjustable from 10 A to 25 A in 2 A steps dimmable in 10 steps with 100 Hz PWM typical voltage drop U0N overload tripping range: 1.01 ...1.30 x lN trip time: adjustable from 100 msec to 6 s current limitation: leakage current wire breakage monitoring of load: wire breakage tresholds: OFF condition: RLoad: typically > 5 kQ ON condition: lLoad typically < 500 mA additional overload protection by means of one E-T-A circuit breaker type 1610-21-30 A per...
Open the catalog to page 2HMK PowerPlex Power Module PP-M-DC024 strain relief return each return each return each return each return each return each mounting bracket (included in delivery) The module is designed for wall mounting by means of the fittings provided Overview (without snap-on cover) This is a metric design and millimeter dimensions take precedence ( address label centre mounting strain relief Caution: Mounting positions
Open the catalog to page 3PowerPlex Power Module PP-M-DC024 Circuit Labels Y 308 539 02 Y 308 539 02 (page 1 of 3) Y 308 539 02 (page 2 of 3) trim tabs hood fuel gauge gas tank level display 3 illumination aft illumination salon courtesy lights water tank sewage tank windshield wiper windshield wiper startboard speedometer V.H.F. transceiver V.H.F. DSC monitor windshield wiper centre windshield wiper portside clear view screen clear view screen startboard M.O.B. bilge alarm fire alarm pyrogenic system clear view screen centre clear view screen portside signal horn klaxon fan fan engine bay fan toilet fan pantry...
Open the catalog to page 5HWK PowerPlex Power Module PP-M-DC024 PP-USBCO: USB/CAN converter incl. product CD configuration software ^\ cable length including Pin assignment D-SUB output plug This is a metric design and millimeter dimensions take Applicable for nominal dimensions without direct tolerance Refer to product datasheet for installation and safety All dimensions without tolerances are for reference only. In the interest of improved design performance and cost effectiveness the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering...
Open the catalog to page 6HMK PP-M-DC024 - Accessories: Circuit Breaker 1610 Miniaturised single pole press-to-reset cycling trip free thermal circuit breaker designed for automotive fuse block installation. Extends the benefits of circuit breaker performance and convenience to applications which are cost critical. Colour-coded housing caps or manual release buttons available. Typical applications Extra low voltage wiring systems on all types of vehicles and marine craft. Ordering information 1610 single pole circuit breaker Voltage rating Current ratings Current ratings, typical voltage drop values and colour...
Open the catalog to page 7HWK PP-M-DC024 - Accessories: Circuit Breaker 1610 Typical time/current characteristic curve .. times rated current The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circu- it breaker current ratings by the derating factor shown below. This is a metric design and millimeter dimensions take precedence (mn? ) All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without...