Catalog excerpts

Thermal Automotive Circuit Breaker 129-L11-H-KF Description Single pole thermal circuit breaker with push-to-reset, tease-free, trip-free, snap action mechanism and separate manual release (M-type TO CBE to EN 60934). Designed for bolt-on mounting with terminal block type 83-P10. Typical applications Extra low voltage wiring systems on all types of vehicles and marine craft. Ordering information Type No. 129 base mounting and connection Terminal design L11 90° bent terminals Manual release H manual release facility Housing KF standard Current ratings 3...25 A 129 - L11 - H - KF - 10 A = ordering example Technical data Standard current ratings and typical internal resistance values Current rating (A) Approvals Authority Rated voltage Current ratings Voltage rating DC 28 V (UL: AC 250 V; DC 50 V) Current ratings 3...25 A Typical life 5,000 operations at 2 x IN Ambient temperature -40...+75 °C (-40...167 °F) Insulation co-ordination rated impulse pollution (IEC 60664 and 60664 A) withstand voltage degree 2.5 kV 2 Dielectric strength (IEC 60664 and 60664A) test voltage operating area AC 1,500 V Insulation resistance > 100 MΩ (DC 500 V) Interrupting capacity Icn 3...5 A 20 x IN 6...25 A 400 A Interrupting capacity IN UN (UL 1077) 0.05...25 A DC 50 V 2,500 A Degree of protection operating area IP32 (IEC 60529/DIN 40050) terminal area IP00 Vibration 10 g (55-2,000 Hz) ± 0.76 mm (10-55 Hz) to VG 95210 part 28 Shock 0 g (11 ms) 5 to VG 95210 part 28 Corrosion 96 hours at 5 % salt mist, to VG 95210 part 2 Humidity 240 hours at 95 % RH to VG 95210 part 7 Mass approx. 25 g
Open the catalog to page 1
Thermal Automotive Circuit Breaker 129-L11-H-KF Typical time/current characteristics at +23 °C/+73.4 °F Trip time in seconds Internal connection diagram The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section Technical information. Ambient temp. °F -40 °C -40 2 Derating factor This is a metric design and millimeter dimensions take precedence ( mm ) inch All dimensions without tolerances are for reference only. In the...
Open the catalog to page 2All E-T-A catalogs and technical brochures
-
REX12 Brochure
24 Pages
-
MPR10, MPR20
5 Pages
-
CATALOGUE
108 Pages
-
CPC20
12 Pages
-
CPC12
8 Pages
-
PC10IO
2 Pages
-
PC10PN
4 Pages
-
PC10PB
4 Pages
-
SVS18
6 Pages
-
1140-E
4 Pages
-
1110
2 Pages
-
127
4 Pages
-
104
4 Pages
-
PowerPlex® Power Module
8 Pages