Description: The 129-L11-H-KF is a single pole thermal circuit breaker designed for automotive and marine applications. It features a push-to-reset, tease-free, trip-free, snap action mechanism with a separate manual release. It is intended for bolt-on mounting with a terminal block type 83-P10.
Typical Applications: This circuit breaker is suitable for extra low voltage wiring systems in vehicles and marine craft.
Ordering Information: The product can be ordered using the format 129-L11-H-KF followed by the desired current rating, e.g., 129-L11-H-KF-10A.
Approvals: The circuit breaker complies with standards such as VDE IEC/EN 60934, UL 1077, CSA C22.2 No 235, and BWB VG 95345 Part 9, supporting various voltage and current ratings.
Technical Data:
  • Voltage Rating: DC 28 V (UL: AC 250 V; DC 50 V)
  • Current Ratings: 3...25 A
  • Typical Life: 5,000 operations at 2 x IN
  • Ambient Temperature: -40...+75 °C (-40...167 °F)
  • Insulation Coordination: Rated impulse withstand voltage 2.5 kV, pollution degree 2
  • Dielectric Strength: AC 1,500 V
  • Insulation Resistance: > 100 MΩ (DC 500 V)
  • Interrupting Capacity: 3...5 A at 20 x IN, 6...25 A at 400 A
  • Degree of Protection: IP32 for operating area, IP00 for terminal area
  • Vibration and Shock Resistance: 10 g and 50 g respectively, compliant with VG 95210 part 28
  • Corrosion and Humidity Resistance: 96 hours at 5% salt mist and 240 hours at 95% RH
  • Mass: Approx. 25 g
Current Ratings and Internal Resistance: The document provides a table of current ratings from 3 A to 25 A with corresponding internal resistance values ranging from 0.1 Ω to less than 0.02 Ω.
Derating Factor: The time/current characteristic curve is affected by ambient temperature. A derating factor is provided to adjust the circuit breaker current ratings to prevent nuisance tripping.
Dimensions and Diagrams: The document includes detailed dimensions in millimeters and inches, along with an internal connection diagram and a typical time/current characteristics graph at +23 °C/+73.4 °F.
See more

Catalog excerpts

129-L11-H-KF-1

Thermal Automotive Circuit Breaker 129-L11-H-KF Description Single pole thermal circuit breaker with push-to-reset, tease-free, trip-free, snap action mechanism and separate manual release (M-type TO CBE to EN 60934). Designed for bolt-on mounting with terminal block type 83-P10. Typical applications Extra low voltage wiring systems on all types of vehicles and marine craft. Ordering information Type No. 129 base mounting and connection Terminal design L11 90° bent terminals Manual release H manual release facility Housing KF standard Current ratings 3...25 A 129 - L11 - H - KF - 10 A = ordering example Technical data Standard current ratings and typical internal resistance values Current rating (A) Approvals Authority Rated voltage Current ratings Voltage rating DC 28 V (UL: AC 250 V; DC 50 V) Current ratings 3...25 A Typical life 5,000 operations at 2 x IN Ambient temperature -40...+75 °C (-40...167 °F) Insulation co-ordination rated impulse pollution (IEC 60664 and 60664 A) withstand voltage degree 2.5 kV 2 Dielectric strength (IEC 60664 and 60664A) test voltage operating area AC 1,500 V Insulation resistance > 100 MΩ (DC 500 V) Interrupting capacity Icn 3...5 A 20 x IN 6...25 A 400 A Interrupting capacity IN UN (UL 1077) 0.05...25 A DC 50 V 2,500 A Degree of protection operating area IP32 (IEC 60529/DIN 40050) terminal area IP00 Vibration 10 g (55-2,000 Hz) ± 0.76 mm (10-55 Hz) to VG 95210 part 28 Shock 0 g (11 ms) 5 to VG 95210 part 28 Corrosion 96 hours at 5 % salt mist, to VG 95210 part 2 Humidity 240 hours at 95 % RH to VG 95210 part 7 Mass approx. 25 g

 Open the catalog to page 1
129-L11-H-KF-2

Thermal Automotive Circuit Breaker 129-L11-H-KF Typical time/current characteristics at +23 °C/+73.4 °F Trip time in seconds Internal connection diagram The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section Technical information. Ambient temp. °F -40 °C -40 2 Derating factor This is a metric design and millimeter dimensions take precedence ( mm ) inch All dimensions without tolerances are for reference only. In the interest...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.