Temperature Sensor with Remote Probe EE471 sensors are used for temperature measurement in applications where a separate housing with remote probe is required for installation. In addition to active outputs 0-10 V or 4-20 mA various types of sensing elements such as Pt1000, NTC10k or Ni1000 are available for passive temperature measurement. Due to an innovative cable outlet and housing concept a high protection class IP65 is provided. Productspecific information for the remote probe is printed all along the cable. External mounting holes Productspecic information » Mounting with closed cover » Protection against construction site pollution Bayonet screws » Open/closed with a ¼ rotation Technical Data Active output Operating temperature Sensing element Output Accuracy Supply voltage (Class III) for 0-10 V for 4-20 mA Current demand Electromagnetic compatibility Passive output 15-35 V DC or 24 V AC ±20% 10 V DC + RL x 20 mA < V+ < 35 V DC DC: typ. 5 mA AC: typ. 12 mAeff EN61326-1, EN61326-2-3 industrial environment Operating temperature Sensing element types Measurement current T-Sensor connection Electrical connection -30 °C…+105 °C (-22 °F...+221 °F) see ordering guide typ. < 1 mA1) two-wire, wire resistance see additional information below screw terminal, 2x max. 2.5 mm2 (0.004 in2) Insulation resistance (remote probe) Response time τ63 > 100 MΩ at 20 °C (68 °F) < 1 min, at 3 m/s (590 ft/min) air velocity < 30 s, with immersion well in liquid water bath stainless steel (1.4571 / 316Ti) PVC polycarbonate, UL94-V0 approved IP65 / NEMA 4 (enclosure and probe) M16x1.5, UL94-V2 -30 °C…+70 °C (-22 °F...+158 °F) 5 % rh...95 % rh, no condensation Sensor sleeve material Cable material Enclosure material Protection class Cable gland Storage temperature Working and storage humidity range 1) according technical data of the specic T-sensors v1.2 / Modification rights reserved
Open the catalog to page 1star pressing Connection Diagram Active output Ordering Guide MODEL ANALOGUE OUTPUT T-SENSOR PASSIVE1) CABLE MATERIAL EE4711) not relevant for active (analogue) output 2) other scaling upon request Order Example Passive Output Active Output EE471-TxxDADPO Model: T-Sensor passive: Cable Material: Cable Length: Housing: Design: Temperature Pt1000 DIN B PVC 2 m (6.6 ft) Standard Standard v1.2 / Modification rights reserved EE471-T3xxAEPO/024M Model: Temperature Analogue Output: 0-10 V Cable Material: PVC Cable Length: 3 m (9.8 ft) Housing: Standard Design: Standard Scaling: -20...80 Unit: °C
Open the catalog to page 2Accessories Product configuration adapter Product configuration software Power supply adapter Conduit adapter, M16x1.5 to 1/2“ see data sheet EE-PCA EE-PCS (free download: www.epluse.com/configurator) V03 (see data sheet Accessories) HA011110 Mounting Immersion well - Thread: R ½’’ ISO Immersion well - Thread: ½’’ NPT stainless steel stainless steel For further information please see datasheet EE431. Mounting with immersion well: 1. The spring inside the well must be removed and replaced by a standard M12x1.5 cable gland (not included in the scope of supply). 2. Insert the remonte cable...
Open the catalog to page 3All E+E ELEKTRONIK catalogs and technical brochures
-
EE671
8 Pages
-
EE650
9 Pages
-
EE680
10 Pages
-
EE576
7 Pages
-
EE660
4 Pages
-
EE75
5 Pages
-
OMNIPORT 30
4 Pages
-
EE060
2 Pages
-
EE07
3 Pages
-
EE071
3 Pages
-
EE072
3 Pages
-
EE074
3 Pages
-
PRODUCT CATALOG
292 Pages
-
HVAC PRODUCT CATALOG
114 Pages
-
EE1950
4 Pages
-
EE310
8 Pages
-
EE10
3 Pages
-
EE071
3 Pages
-
EE07-02
2 Pages
-
humidity_calib
1 Pages
-
accessories
8 Pages
-
EE046
2 Pages
-
HVAC-Brochure
8 Pages
-
datasheet EE46
2 Pages
-
E+E Product Catalog
256 Pages
-
EE061
2 Pages
-
HCT01
4 Pages
-
EE431
3 Pages
-
EE441
2 Pages
-
EE451
3 Pages
-
EE461
2 Pages
-
EE10
2 Pages
-
EE08
2 Pages
-
EE07
2 Pages
-
EE04
2 Pages
-
EE060
2 Pages
-
EE03
2 Pages
-
EE02
1 Pages
-
EE210
5 Pages
-
EE160
4 Pages
-
EE-PCA
2 Pages