EE300EX-HT - Humidity/Temperature Transmitter for Intrinsically Safe Applicatons
6Pages

{{requestButtons}}

Catalog excerpts

EE300EX-HT - Humidity/Temperature Transmitter for Intrinsically Safe Applicatons - 1

Humidity/Temperature Transmitter for Intrinsically Safe Applications The EE300Ex humidity / temperature transmitter has been designed specifically for measurement in explosion hazard areas. It complies with the classifications for Europe (ATEX), International (IECEx) and USA / Canada (FM). Accurate measurement over the full range of 0…100 % RH and -40…180 °C (-40...356 °F) is also possible in applications under pressure from 0.01 … 300 bar (4351 psi). The EE300Ex can be used in flammable gas and dust applications. The entire transmitter can be placed in a explosion hazardous area. With the remote sensing probe a temperature classification up to T6 can be reached. With a stainless steel enclosure and sensing probe the EE300Ex is the ideal transmitter for challenging industrial applications. The 2-part construction facilitates simple installation and rapid replacement of the measuring section without time consuming wiring. The well proven E+E humidity sensors ensure reliable measurement performance and long term stability. Based on 2-wire technology, the transmitter can be powered by any intrinsically safe power source or via Zener barriers. The measured values are available on two 4…20mA analog outputs. In addition to the measured values for humidity and temperature, the EE300Ex calculates dew point, frost point, absolute humidity, mixing ratio and other humidity related physical quantities. EE300Ex - remote sensing probe When outside of the hazardous measurement area, the setup of the EE300Ex can be easily customized by using the supplied configuration software. This includes the configuration of the analog outputs and the calibration of the humidity and temperature during service. Measurement of moisture in oil: Besides measurement in the air, the EE300Ex can be employed for measurement of both absolute water content (x) in ppm or relative water activity (aw) in oils. Typical applications include oil purifiers and online monitoring of lubrication and hydraulic oils on off shore oil rigs. The USA and Canada approval is valid for air and gas measurement only. Dew point measurement in natural gas. EE300Ex measures reliably dew point in natural gas down to -20 °C (-4 °F) at a line pressure up to 250 bar (3625 psi). The optional sensor retraction tool (see accessories) allows for easily installation and removal of the sensing probe for service or calibration without interruption of the gas flow in the pipeline. Typical Applications chemical process control pharmaceutical applications explosive / hazardous storage rooms flour mills moisture in oil measurement dew point measurement in natural gas hubs 18 Features approved for gas and dust installation in zone 0 / Div. 1 calculation of related physical quantities stainless steel housing and probe highest accuracy up to 180 °C (356 °F) pressure tight up to 300 bar (4351 psi) v2.1 / Modification rights reserved

Open the catalog to page 1
EE300EX-HT - Humidity/Temperature Transmitter for Intrinsically Safe Applicatons - 2

Display Two of the measured or calculated physical quantities can be selected with push buttons on the front cover to be shown on the optional display. EE300Ex version with display is not available for environments with combustible dust, Fibers and Flyings and gases with EPL Ga IIC (Group A&B). The gray area shows the allowed measurement range for the humidity sensor. Operating points outside of this range do not lead to destruction of the sensing element, but the specified measurement accuracy cannot be guaranteed. Harsh industrial processes as well as heavily contaminated and/ or...

Open the catalog to page 2
EE300EX-HT - Humidity/Temperature Transmitter for Intrinsically Safe Applicatons - 3

Technical Data EE300Ex Measuring values Humidity sensor HC1000 1) Measuring range 0...100 % RH 2) Accuracy (including hysteresis, non-linearity and repeatability, traceable to international standards, administrated by NIST, PTB, BEV...) -15...40 °C (5...104 °F)≤90 % RH ± (1.3 + 0.3%*mv) % RH ± 2.3% RH -15...40 °C (5...104 °F)>90 % RH -25...70 °C (-13...158 °F) ± (1.4 + 1%*mv) % RH -40...180 °C (-40...356 °F) ± (1.5 + 1.5%*mv) % RH Temperature dependence electronics typ. 0.03 % RH/°C Response time with filter at 20 °C (68 °F) / t90 < 30 sec. Temperature sensor Measuring range sensor head...

Open the catalog to page 3
EE300EX-HT - Humidity/Temperature Transmitter for Intrinsically Safe Applicatons - 4

Ex - Classifications Europe (ATEX) Certificate: TPS 13 ATEX 38892 003 X by TÜV SÜD Product Service GmbH Safety factors: Ex-Designation: Transmitter without display Transmitter with display Remote sensing probe International (IECEx) Safety factors: Ex-Designation: Transmitter without display Transmitter with display Remote sensing probe Safety factors: Ex-Designation: Transmitter without display Transmitter with display Remote sensing probe Mounting Example IS/I,II,III/1/ABCDEFG/T4 -40°C < Ta < 60°C; Entity – M1_1309080; IP65 USA: NI/I,II,III/2/ABCDEFG/T4 -40°C < Ta < 60°C Canada:...

Open the catalog to page 4
EE300EX-HT - Humidity/Temperature Transmitter for Intrinsically Safe Applicatons - 5

Ordering Guide EE300Ex-HT EE300Ex-HT6S Model Display Electrical Connection Hardware Configuration Probe - Cable Length Probe Length Zone Feedthrough (probe fitting) Sensor Protection Ex-Certification Special option Measured Value Units Software Configuration Physical Parameters Output 1 Scaling Range Output 1 Physical Parameters Output 2 Scaling Range Output 2 1) No wall mounting remote sensing probe up to 20 bar (300p si) remote sensing probe up to 300 bar (4351 psi) remote sensing probe for sensor retraction tool PN250 without display with display 1) 2 x M16 cable gland wall mounting 1 m...

Open the catalog to page 5
EE300EX-HT - Humidity/Temperature Transmitter for Intrinsically Safe Applicatons - 6

Scaling Ranges UW - Relative Humditiy [% RH] 001 Tx - Temperature / TD - Dew Point Temperature / TF- Frost Point Temperature / TW- Wet Bulb Temperature [°C or °F] 002 Ex - Water vapour partial pressure [mbar] 001 Hx - Specific Enthalphy [kJ/kg] 001 Other scaling ranges on request. Order Example Example 1: EE300EX-HT6SMDBHFAD1AT/MTx052UW001 Model: Display: Electrical Connection: Probe - Cable Length: Probe Length: Zone feedthrough: Filter: Sensor Protection: Ex-Certification: remote sensing probe up to 300bar with display 2 x M16 cable gland 10 m (32.8 ft) 200 mm (7.9) 1/2 ISO - cut-in...

Open the catalog to page 6

All E+E ELEKTRONIK catalogs and technical brochures

  1. EE671

    8 Pages

  2. EE650

    9 Pages

  3. EE680

    10 Pages

  4. EE576

    7 Pages

  5. EE660

    4 Pages

  6. EE75

    5 Pages

  7. OMNIPORT 30

    4 Pages

  8. EE060

    2 Pages

  9. EE07

    3 Pages

  10. EE071

    3 Pages

  11. EE072

    3 Pages

  12. EE074

    3 Pages

  13. PRODUCT CATALOG

    292 Pages

  14. EE1950

    4 Pages

  15. EE310

    8 Pages

  16. EE10

    3 Pages

  17. EE071

    3 Pages

  18. EE07-02

    2 Pages

  19. accessories

    8 Pages

  20. EE046

    2 Pages

  21. EE061

    2 Pages

  22. HCT01

    4 Pages

  23. EE431

    3 Pages

  24. EE441

    2 Pages

  25. EE451

    3 Pages

  26. EE461

    2 Pages

  27. EE471

    3 Pages

  28. EE10

    2 Pages

  29. EE08

    2 Pages

  30. EE07

    2 Pages

  31. EE04

    2 Pages

  32. EE060

    2 Pages

  33. EE03

    2 Pages

  34. EE02

    1 Pages

  35. EE210

    5 Pages

  36. EE160

    4 Pages

  37. EE-PCA

    2 Pages