EE210 Datasheet-1

your partner in sensor technology. DatasheetEE210 Humidity and Temperature Sensor for Demanding Climate Control

 Open the catalog to page 1
EE210 Datasheet-2

EE210 Humidity and Temperature Sensor for Demanding Climate Control The EE210 humidity (RH) and temperature (T) sensor is designed to meet the highest requirements in demanding climate control applications. Besides the accurate measurement of RH and T EE210 calculates various RH related parameters such as dew point temperature, absolute humidity and mixing ratio. Outstanding Measurement Performance Excellent performance of EE210 in polluted or aggressive environment is ensured by the encapsulated measurement electronics inside the sensing probe and the long-term stable E+E sensing element with...

 Open the catalog to page 2
EE210 Datasheet-3

Features Display ▪ Selectable display layout ▪ Measurands freely selectable ▪ Backlight optional Knockout for ½" conduit fitting (US) Enclosure ▪ Protection rating IP65 / NEMA 4X External mounting holes ▪ Type T13 compatible with ▪ Mounting with closed cover ▪ Electronics protected against construction site pollution ▪ Easy and fast mounting Smooth cover surface ▪ Optimum protection against mechanical damage during installation Bayonet screws ▪ Open / close with a ¼ rotation Cast electronics ▪ Mechanical protection E+E RH and T Sensing Element ▪ Outstanding long-term stability ▪ Protected solder...

 Open the catalog to page 3
EE210 Datasheet-4

FeaturesProtective Sensor Coating The E+E proprietary sensor coating is a protective layer applied to the active surface of the sensing element. The coating substantially extends sensor lifetime and ensures optimal measurement performance in corrosive environment (salts, offshore applications). Additionally, it improves the sensors' long term stability in dusty, dirty or oily applications by preventing stray impedance caused by deposits on the active sensor surface. encapsulated electronics Dimensions Values in mm (inch) Type T1 (wall mount) Type T2 (duct mount) www.epluse.com v2.15 / All rights...

 Open the catalog to page 4
EE210 Datasheet-5

Dimensions Values in mm (inch) Mounting flange in the scope of supply for type T2 and T3 Radiation shield HA010501 for type T13 (outdoor) needs to be ordered separately www.epluse.com v2.15 / All rights reserved | 5

 Open the catalog to page 5
EE210 Datasheet-6

Technical Data Measurands Relative humidity (RH) Measuring range Accuracy1) incl. hysteresis, non-linearity and repeatability Type T1, T2 -15...+40 °C (+5...+104 °F), ≤90 %RH -15...+40 °C (+5...+104 °F), >90 %RH -40...+60 °C (-40...+140 °F) 1) Traceable to international standards, administrated by NIST, PTB, BEV,... The accuracy statement includes the uncertainty of the factory calibration with an enhancement factor k=2 (2-times standard deviation). The accuracy was calculated in accordance with EA-4/02 and with regard to GUM (Guide to the Expression of Uncertainty in Measurement). For Type T13:...

 Open the catalog to page 6
EE210 Datasheet-7

Technical Data Measurands 1) Td accuracy according to RH and T uncertainties, please use the E+E Humidity Caclulator for details. Two freely selectable and scalable outputs Digital Digital interface

 Open the catalog to page 7
EE210 Datasheet-8

Technical Data General 1) For display operation with EE210-M1xA6 (4 - 20 mA, 2-wire) both outputs must be connected.

 Open the catalog to page 8
EE210 Datasheet-9

Ordering Guide Feature 1) The PE210 probe has to be ordered as seperate position. 2) Factory setup: For analogue output versions the display shows the measurands selected for output 1 and output 2. For digital output versions the display shows RH and T. 5) Modbus Map and setup instructions: See User Guide and Modbus Application Note at www.epluse.com/ee210.

 Open the catalog to page 9
EE210 Datasheet-10

Measurand CodeFor Output 1 and 2 in the Ordering Guide Measurand PLEASE NOTE No mix of SI/US units allowed. Order Examples Type T1 and T2

 Open the catalog to page 10
EE210 Datasheet-11

Order Examples Type T3 Position 1: Basic Device Radiation shield for EE210 Outdoor.

 Open the catalog to page 11
EE210 Datasheet-12

Accessories For further information refer to “Accessories” the datasheet.

 Open the catalog to page 12
EE210 Datasheet-13

Company Headquarters & Production Site 4209 Engerwitzdorf | Austria T +43 7235 605-0 F +43 7235 605-8 [email protected] www.epluse.com E+E Sensor Technology (Shanghai) Co., Ltd. E+E Elektronik France SARL E+E Elektronik Deutschland GmbH T +49 6171 69411-0 [email protected] E+E Elektronik India Private Limited T +91 990 440 5400 [email protected] E+E Elektronik Corporation T +1 847 490 0520 [email protected] datasheet_EE210 | Version v2.15 | 11-2024 © Copyright E+E Elektronik Ges.m.b.H. | All rights reserved. your partner in sensor technology.

 Open the catalog to page 13

All E+E ELEKTRONIK catalogs and technical brochures

  1. Datasheet EE451

    10  Pages

  2. Datasheet EE471

    10  Pages

  3. Datasheet EE431

    11  Pages

  4. Datasheet EE741

    13  Pages

  5. Datasheet EE771

    13  Pages

  6. Datasheet EE772

    13  Pages

  7. Datasheet EE776

    13  Pages

  8. Datasheet EE660

    10  Pages

  9. Datasheet EE680

    10  Pages

  10. CDS201

    9  Pages

  11. Datasheet EE872

    10  Pages

  12. Datasheet EE372

    10  Pages

  13. Datasheet EE360

    12  Pages

  14. Datasheet EE371

    10  Pages

  15. HC103M2

    2  Pages

  16. Datasheet EE072

    10  Pages

  17. Accessories

    34  Pages

  18. EE220 Datasheet

    10  Pages

  19. EE212 Datasheet

    11  Pages

  20. EE310 Datasheet

    10  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.