PRODUCT CATALOG
Open the catalog to page 1new compact dew point transmitter down to -60 °C Measurement range -60…60 °C Td (-76...140 °F Td) E+E autocalibration Measurement accuracy ±2 °C (3.6 °F) Condensation resistant and fast recovery after dewing Modbus RTU and 4..20 mA output Sturdy and compact stainless steel housing Air velocity transmitter for very low air velocity Measurement from 0.15 m/s Excellent long term stability Lowest sensitivity to dirt and Small angle dependence Large, easily readable Display with background illumination Designs: duct mount, wall mount, remote probe temperature sensor for HVAC and building...
Open the catalog to page 3Humidity / Temperature Transmitter for High Humidity and Chemical Applications The highly accurate EE33 series are designed for fast and reliable measurement of relative humidity / dew point temperature / absolute humidity / ...under the most demanding conditions. Neither condensation nor heavy chemical pollutions will affect prompt and reliable measurements. Process pressures as high as 100 bar (1450 psi) and continuous high humidity are also no problem for the EE33 series. The core of the EE33 series is the new monolithic measurement cell type HMC01, manufactured in thin-film technology...
Open the catalog to page 6Measurement of humidity and temperature 2 freely scaleable and configurable analogue outputs Remote sensing probe up to 20m (65.6ft) On-site adjustment for relative humidity and temperature LED indication of transmitter status / error diagnosis of probes Alternating display with MIN/MAX indication optional 2 freely configurable alarm outputs optional Removeable sensing probe optional Sensor protection with coating optional Pluggable electrical connections optional Data output via RS232 interface ^ Data output via RS485 interface optional Networking for up to 32 transmitters via RS485 bus...
Open the catalog to page 7Connection Versions standard power supply+ analogue output power supply+ analogue output Sensing probes: code “cable length” code “probe length” EE33-MFTEx Pressure tight probe up to 20 bar Probe material: stainless steel Remote Probe: code “cable length” code “cable length” 15 *) L = Filter length: refer to data sheet „Accessories“ EE33-MFTCx EE33-MFTDx Remote sensing probe Probe material: stainless steel code “probe length” code “probe length” EE33-MFTIx Pressure tight probe up to 100 bar Probe material: stainless steel code “cable length” code “probe length” EE33-MFTKx Remote sensing...
Open the catalog to page 8Technical Data Measurement values Relative humidity 1) Humidity sensor heated, monolithic measurement cell HMC01 1) Working range 0...100 % RH Accuracy*) (including hysteresis, non-linearity and repeatability, traceable to intern. standards, administrated by NIST, PTB, BEV...) ± (1.3 + 0.3%*mv) % RH -15...40 °C (5...104 °F) ≤90 % RH -15...40 °C (5...104 °F) >90 % RH ± 2.3% RH -25...70 °C (-13...158 °F) ± (1.4 + 1%*mv) % RH -40...180 °C (-40...356 °F) ± (1.5 + 1.5%*mv) % RH Temperature dependence of electronics typ. ± 0.01 % RH/°C (0.0055 % RH/°F) Response time with metal grid filter at 20°C...
Open the catalog to page 9^^^^^^m YOUR PARTNER IN SENSOR TECHNOLOGY Technical Data for Options graphical LC display (128x32 pixels) parameters and M IN/MAX function_ with integrated push-buttons for selecting Alarm outputs threshold + hysteresis: can be adjusted with configuration software 1 0 v1.11 / Modification rights reserved
Open the catalog to page 10Ordering Guide Hardware Configuration Housing Type Model Filter Cable length (incl. probe length) Probe length Pressure tight feedthrough Interface Display Alarm output Sensing probe Coating sensor Supply voltage Software Configuration Physical parameters of outputs Type of output signal Measured value units T-Scaling Td-Scaling Tf-Scaling Tw-Scaling (in °C or °F) PTFE stainless steel filter stainless steel sintered filter PTFE filter H2O2 filter stainless steel grid filter(up to 180°C/ 356 °F) 2 m (6.6 ft) 5 m (16.4 ft) 10 m (32.8 ft) 65 mm (2.6”) (for model E: 80mm (3.1”)) 200 mm (7.9”)...
Open the catalog to page 11Multifunctional Industrial Transmitter for Humidity / Temperature / Dew Point / Absolute Humidity... The precise and reliable measurement of humidity in industrial processes is gaining more and more importance. The multifunctional transmitters series EE31 offer the ideal solution. The result of many years of experience in humidity measurement technology for industrial applications, the EE31 series builds on the E+E high-quality HC series capacitive humidity sensor elements. The optimal hardware structure for varying applications is achieved by combining various standard mechanical and...
Open the catalog to page 12Software Tools Configuration Software (included in the scope of supply): The Configuration Software is used for: - flexible, easy and fast setup of the analogue and alarm outputs. - adjustment of the humidity and temperature outputs. - exchange of the sensing probe or of the sensors. Datalogging and Analysis Software (optional): This user friendly software tool is a great help for easy data analysis in graphical or spreadsheet format on a PC as well as for data and alarms management by e-mail or SMS. Easy calibration and adjustment of the transmitter The modular housing of the EE31 enables...
Open the catalog to page 13Connection versions plug option C06 power supply+ analogue output power supply+ RS485 network analogue output Dimensions in mm Housing: polycarbonate housing For use in harsh industrial environments all models of the EE31 are available in a robust metal housing. The very smooth surface and the rounded outlines allow for the use in clean rooms as well. Models: code “cable length” L*) EE31-xDx Remote probe for T up to 180°C (356°F) Probe material: stainless steel EE31-xAx Wall mounting Probe material: PC code “probe length” code “cable length” EE31-xBx Duct mounting Probe material: stainless...
Open the catalog to page 14Technical Data Measurement values Relative humidity 1) Humidity sensor HC1000-400 1) Working *)range 0...100% RH Accuracy (including hysteresis, non-linearity and repeatability, traceable to intern. standards, administrated by NIST, PTB, BEV...) ≤90% RH ± (1.3 + 0.3%*mv) % RH -15...40°C (5...104°F) -15...40°C (5...104°F) >90% RH ± 2.3% RH -25...70°C (-13...158°F) ± (1.4 + 1%*mv) % RH -40...180°C (-40...356°F) ± (1.5 + 1.5%*mv) % RH Temperature dependence of electronics typ. ± 0.01% RH/°C (0.0055% RH/°F) Response time with metal grid filter at 20°C / t90 < 15s Temperature sensor element...
Open the catalog to page 15All E+E ELEKTRONIK catalogs and technical brochures
-
EE671
8 Pages
-
EE650
9 Pages
-
EE680
10 Pages
-
EE576
7 Pages
-
EE660
4 Pages
-
EE75
5 Pages
-
OMNIPORT 30
4 Pages
-
EE060
2 Pages
-
EE07
3 Pages
-
EE071
3 Pages
-
EE072
3 Pages
-
EE074
3 Pages
-
PRODUCT CATALOG
292 Pages
-
HVAC PRODUCT CATALOG
114 Pages
-
EE1950
4 Pages
-
EE310
8 Pages
-
EE10
3 Pages
-
EE071
3 Pages
-
EE07-02
2 Pages
-
humidity_calib
1 Pages
-
accessories
8 Pages
-
EE046
2 Pages
-
HVAC-Brochure
8 Pages
-
datasheet EE46
2 Pages
-
EE061
2 Pages
-
HCT01
4 Pages
-
EE431
3 Pages
-
EE441
2 Pages
-
EE451
3 Pages
-
EE461
2 Pages
-
EE471
3 Pages
-
EE10
2 Pages
-
EE08
2 Pages
-
EE07
2 Pages
-
EE04
2 Pages
-
EE060
2 Pages
-
EE03
2 Pages
-
EE02
1 Pages
-
EE210
5 Pages
-
EE160
4 Pages
-
EE-PCA
2 Pages