EPR5-1

DYNISCO MODELS EPR5 & EPR6 Amplified Output, Enhanced Push-Rod Design Melt Pressure Transmitters Description Dynisco models EPR5 and EPR6 high - temperature melt pressure transducers feature a built - in amplifier to provide a 0 to 5 Vdc (EPR5) or 0 to 10 Vdc (EPR6) output to a DCS or computer system. An alternative to Dynisco's PT420 and PT460 series, the push - rod design is suitable for applications where the use of a filled system may not be desirable, such as the extrusion of food and medical products and the manufacture of photographic film. These models are available in pressure ranges from 0 - 1,500 through 0 - 10,000 psi. Features Benefits • Better than ±0.5% accuracy • Push - rod design • Reliable pressure measurement • Ideal for medical, food and photographic film extrusion • Ideal for high temperature processes • Corrosion resistant • Easy set - up • Choice of outputs • • • • Measures up to 750˚F (400˚C) All stainless steel, wetted parts Internal 80% shunt calibration 0 - 5 Vdc or 0 - 10 Vdc outputs Specifications New Extended Life Coating Performance Characteristics Ranges (psi): 0 - 1,500, 0 - 3,000, 0 - 5,000, 0 - 7,500, 0 - 10,000 Accuracy: ±0.5% FSO Repeatability: ±0.2% FSO Mounting torque: 100 inch - lbs. recommended, 250 inch - lbs. maximum Maximum pressure: 150% full scale Material in contact with pressure media: 17 - 4 PH stainless steel, DyMax™ coated Weight: 1.3 lbs. Electrical Characteristics EPR5: Output: 0 to 5 Vdc, 4 - wire Input voltage: 11 to 32 Vdc Load resistance: 2,000 Ohms minimum Zero adjustment: ±10% Span adjustment range: ±5% Shunt calibration: 80% ±1.0% FSO EPR6: Output: 0 to 10 Vdc, 4 - wire Input voltage: 16 to 32 Vdc Load resistance: 2,000 Ohms minimum Zero adjustment: ±10% Span adjustment range: ±5% Shunt calibration: 80% ±1.0% FSO Temperature Characteristics Transducer diaphragm: Maximum diaphragm temperature: 750°F (400°C) Zero shift due to temperature change: ±1.0% full scale/100°F (±2.0% full scale/100˚C) Sensitivity shift due to temperature change: ±1.0% full scale/100°F (±2.0% full scale/100°C) 128 Electronics housing: Operating temperature range: -20˚F to +160˚F (-29˚C to +71˚C) Temperature effects over a compensated range of +30˚F to +160˚F (-1˚C to +71˚C): Temperature effect on zero: ±3.0% of full scale/100˚F maximum Temperature effect on sensitivity: ±2.0% of full scale/100˚F

 Open the catalog to page 1

All Dynisco catalogs and technical brochures

  1. PT4196

    3  Pages

  2. PT46X6

    3  Pages

  3. PT46X5

    3  Pages

  4. TI422

    1  Page

  5. DYMT

    2  Pages

  6. DYKE

    2  Pages

  7. TB422J

    1  Page

  8. TG422

    1  Page

  9. PT460XL

    3  Pages

  10. MRT 460

    2  Pages

  11. DYN-X

    3  Pages

  12. PT130

    2  Pages

  13. MDA460

    2  Pages

  14. Echo

    3  Pages

  15. LDA415

    2  Pages

  16. EPR3

    2  Pages

  17. MDA435

    2  Pages

  18. MDA420

    2  Pages

  19. MDA410

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.