PA10VSO Series - 1

Type code for standard program PA10VS Standard version (without symbol) HFA, HFB, HFC hydraulic fluid (except for Skydrol) High-speed version Axial piston unit Swashplate design,variable,nominal pressure 4000 psi(280 bar), maximum pressure 5100 psi(350 bar) Pump, open circuit Geometric displacement, see table of values on pages 6 and 7 Control device Two-point control, directly operated l l Pressure control with flow control, hydraulic X-T open X-T closed with swivel-angle control,eletric pressure and swivel-angle control, electric with pressure cut-off, remotely operated hydraulic electrical negative characteristic positive characteristic Pressure, flow and power control Viewed on drive shaft 1)The following must be taken into account during project planning: Excessive current levels (I >1200 mA with 12 V or I > 600 mA with 24 V) to the ER solenoid can result in undesiredincrease of pressure which can lead to pump or system damage: - Use Imax current limiter solenoids. - A sandwich plate pressure reducing valve can be used to protect the pump in the event of overflow. An accessory kit with pressure reducing sandwich plate can be ordered from DYNATEC. ¹ Coupling for splined shaft according to ANSI B92.1a ² Other electrical connector might be diffenrent ³ Peference: SAE version from A-39 dynat

Open the catalog to page 1
PA10VSO Series - 2

Type code for standard program A Splined shaft ANSI B92.1a 9 standard shaft similar to shaft "S" however for higher input torque reduced diameter, not for through drive same as "U", higher torque; not for through drive Parallel keyed shaft Metric DIN 6885 Not for through drive SAE ISO 3019-1 Note: Same splined shaft for SAE/Metric 18 Service line port SAE flange ports on opposite side,UNC fastening thread without through drive Flange ISO 3019-1 Diameter 82-2 (A) 101-2 (B) 127-2 (C) Through drive SAE flange ports on opposite side,metric-fastening thread HIRSCHMANN connector – without...

Open the catalog to page 2
PA10VSO Series - 3

Technical data Notes on the choice of hydraulic fluid Hydraulic fluid In order to select the correct hydraulic fluid, it is necessary to know the operating temperature in the reservoir (open circuit) in relation to the ambient temperature. When using environmentally acceptable hydraulic fluids,the limitations regarding technical data and seals must be observed.Please contact us.When ordering,indicate the hydraulic fluid that is to be used. The hydraulic fluid should be selected so that within the operating temperature range, the viscosity lies within the optimum range(νopt), see shaded...

Open the catalog to page 3
PA10VSO Series - 4

Technical data Operating pressure range Pressure at service line port B Nominal pressure pnom The nominal pressure corresponds to the maximum Maximum pressure pmax ____5100 psi (350 bar) absolute design pressure. Nominal pressure pnom _____4000 psi (280 bar) absolute ms Total operating period _________________________300 h Min. pressure(high-pressure side) _145 psi (10 bar) absolute¹ Maximum pressure pmax The maximum pressure corresponds to the maximum operating pressure within the single operating period. The total of the single operating periods must not exceed the total operating period....

Open the catalog to page 4
PA10VSO Series - 5

Technical data, standard unit Table of values (theoretical values, without efficiencies and tolerances: values rounded) NG Geometrical displacement per revolution Vg max Size lb-ft/rad (Nm/rad) lb-ft/rad (Nm/rad) lb-ft/rad (Nm/rad) lb-ft/rad (Nm/rad) Rotary stiffness, drive shaf maximum at Vg < Vg max Flow nnom and Vg max lb-ft/rad (Nm/rad) lbs-ft² (kgm²) Moment of inertial rotary group Angular acceleration, maximum² α Filling capacity V Weight (without through drive) m The values are applicable: ¹ - for an absolute pressure pabs = 15 psi (1 bar) at suction port S - within the optimum...

Open the catalog to page 5
PA10VSO Series - 6

Technical data, high-speed version Table of values (theoretical values, without efficiencies and tolerances: values rounded) NG Geometrical displacement per revolution Vg max in³ (cm³) Speed ¹ nnom rpm maximum at Vg max nmax perm rpm maximum at Vg < Vg max Rotary stiffness, drive shaf Moment of inertial rotary group JTW Angular acceleration, maximum² α V Filling capacity m Weight (without through drive) lb-ft/rad (Nm/rad) lb-ft/rad (Nm/rad) lb-ft/rad (Nm/rad) lb-ft/rad (Nm/rad) lb-ft/rad (Nm/rad) lbs-ft² (kgm²) The values are applicable: ¹ - for an absolute pressure pabs = 15 psi(1 bar) at...

Open the catalog to page 6
PA10VSO Series - 7

Technical data Permissible radial and axial loading on the drive shaft Size Radial force maximum Fq at a/2 Axial force maximum Permissible input and through-drive torques at Vg max and ∆p = 4000 psi (280 bar)¹ Input torque for drive shaft, maximum² Maximum through-drive torque for drive shaft S TD max lb-ft (Nm) TD max lb-ft (Nm) R P K Without considering efficiency ² For drive shafts free of radial load ¹

Open the catalog to page 7
PA10VSO Series - 8

Technical data Drive power Working position : Flow ISO VG 46 DIN 51519,t = 50 °C size 28 _ _ _ _n = 1500 rpm ______n = 3000 rpm

Open the catalog to page 8
PA10VSO Series - 9

DG — Two-point control, directly operated The variable pump can be set to a minimum swivel angle by connecting an external control pressure to port X. This will supply control fluid directly to the stroke piston; a minimum control pressure of pst ≥ 725 psi (50 bar) is required.。 The variable pump can only be switched between Vg max or Vg min 。 Please note, that the required control pressure at port X is directly dependent on the actual operating pressure pB in port B. (See control pressure characteristic). Control pressure pst = 0 psi (0 bar) Control pressure pst ≥ 725 psi (50 bar) Control...

Open the catalog to page 9
PA10VSO Series - 10

DR — Pressure control Circuit diagram,sizes 18 to 100 Hysteresis / pressure rise Static characteristic Setting rang¹ The pressure control limits the maximum pressure at the pump output within the pump control range. The variable pump only supplies as much hydraulic fluid as is required by the consumers.If the operating pressure exceeds the pressure setpoint set at the integrated pressure valve, the pump will adjust towards a smaller displacement and the control deviation will be reduced. The pressure can be set steplessly at the control valve. ¹ In order to prevent damage to the pump and...