| Model | Output Force (Sinus) | Output Force (Shock) | Frequency Range | Displacement (Peak to Peak) | Max Acceleration | Total Mass | Cooling System | Suspension | Max. Input Current | Amplifier | Input Voltage |
|---|---|---|---|---|---|---|---|---|---|---|---|
| PM-20 | 20 N | 40 N | 0 - 12 kHz | 5 mm | 30 g | 4.1 kg | Air Con. | Spring | 4A | Integrated | 1 VAC |
| PM-100 | 100 N | 200 N | 0 – 8 kHz | 10 mm | 45 g | 9 kg | Air Con. | Spring | 6A | Integrated | 1 VAC |
| PM-250 | 250 N | 500 N | 0 – 5 kHz | 25 mm | 80 g | 15 kg | Forced Air | Spring | 10A | External | 10 VAC |
| PM-440 | 440 N | 880 N | 0 – 5 kHz | 25 mm | 80 g | 15 kg | Forced Air | Spring | 10A | External | 10 VAC |
Dynalabs permanent magnet shakers are compact, lightweight and powerful general-purpose shakers which can be used for modal and vibration testing. They have high DUT capacity despite their small sizes. PM-20 and PM-100 has an integrated amplifier and a sine wave signal generator where the frequency can be adjusted from 1 Hz to 12,000 Hz. Advantages: • Lightweight, durable, portable and easy to use • Adjustable trunnion base provides high degree of flexibility • Broad frequency range • Embedded power amplifier and signal generator for PM-20 and PM-100 Output Force (Sinus) Output Force (Shock) Frequency range Displacement (Peak to Peak) Max Acceleration Total mass Cooling system Suspension Max. Input Current AMPLIFIER Input Voltage PM-250 250 N 500 N 0 - 5 kHz 25 mm 80 g 15 kg Forced Air Spring 10A External 10 VAC PM-440 440 N 880 N 0 - 5 kHz 25 mm 80 g 15 kg Forced Air Spring 10A External 10 VAC Protections for PM-250 and PM-500 • Over travel switch • Over current fuse Ankara / TURKEY [email protected] www.dynalabs.com.tr