1. Catalogs
  2. DXG Ltd.
  3. LGH-80 Catalog

LGH-80 Catalog

LGH-80 Catalog

Product catalog summary
System Components
Main Unit, Sample Probe, Heating Chamber, Measuring Chamber, Flow Control Unit, Purge Motor Unit (including Air pump, Air Filter, Air hose), Cables, and Master Flange. Optional component includes the PGA-91 Pitot Tube Flowmeter.
Certificates and Approvals
Includes Type Approval from Korea.
Features
Optimized for high humidity environments using a wet measurement method. Capable of measuring concentrations as low as 0.05 mg/m³ using the Forward Light Scattering Principle. Ensures extended component lifespan by sampling gas within the duct using the ejector principle. Prevents sampling errors through isokinetic sampling and evaporates moisture in collected gas for accurate measurements. Prevents dust deposition in the sample line through a periodic blowback cycle and compensates for optical contamination effects on measurements through a periodic span check cycle.
Measurement Conditions
Temperature range: -20 to +60 °C, Gas temperature: < +150 °C, Gas flow rate: 4 to 20 m/s, Gas pressure: -50 to 20 mbar, Gas humidity: < 1 Weight %.
Purge Motor Unit Specifications
Dimensions: W550 x D350 x H850 mm, Weight: 15 kg, Voltage: 3P 480 VAC, Power: 1.5 kW.
Probe Specifications
Materials: PVDF, Length: 0.5 to 2.5 m (Adjustable), Weight: 0.5 kg.
Analyzer Main Unit Specifications
Material: SUS 304, Dimensions: W800 x D600 x H1806 mm, Weight: 45 kg, Voltage: 110/220 VAC, 50/60 Hz, Power: 2 kW.
Communication and Interface
1 Channel, 4 to 20 mA, 4 Channel, 1 Channel, 7" LCD Touch Panel, RS232, RS422, RS485.
Technical Specifications
Measured Components: Dust, Measurement Principles: Forward Light Scattering, Min. Measuring Unit: 0.05 mg/m³, Zero Drift (24 hours): < ± 1% FS, Span Drift (24 hours): < ± 2% FS, Repeatability: < ± 1% FS, Linearity: < ± 2% FS, Response Time: < 5 seconds, 1 to 600 sec (selectable), Measuring Ranges: Min 0 to 15 / Max 0 to 200 mg/m³.
See more

Catalog excerpts

LGH-80 Catalog-1

Forward Light Scattering Dust (Wet type) Extractive Technical Specifications Measured Components Measurement Principles Measuring Ranges Measurable Minimum Thickness Min. Measuring Unit Zero Drift (24 hours) Span Drift (24 hours) Repeatability Linearity Response Time Dust Forward Light Scattering Min 0~15 / Max 0~200 mg/m3 System Components Main Unit / Sample Probe / Heating Chamber Measuring Chamber and Flow Control Unit Purge Motor Unit (Air pump, Air Filter, Air hose) Cables / Master Flange PGA-91 Pitot Tube Flowmeter Certificates Type Approval (Korea) Approvals 01 Optimized for high humidity environments using a wet measurement method 02 Capable of measuring concentrations as low as 0.05 mg/m3 using forward scatter with Forward Light Scattering Principle 03 Ensures extended component lifespan by sampling gas within the duct using the ejector principle 04 Prevents sampling errors through isokinetic sampling Evaporates moisture in collected gas for accurate 05 measurements and prevents concentration errors due to moisture condensate Prevents dust deposition in the sample line through 06 periodic blowback cycle Compensates for optical contamination effects on 07 measurements through periodic span check cycle Other Specifications Measurement Conditions Operating Temperature Gas Temperature Gas flow rate Gas Pressure Gas Humidity Analyzer Main Unit Materials Dimensions Weight Voltage Power Consumption Analog Outputs Digital Outputs Digital Inputs Display & Input Device Interface 1 Channel, 4 ~ 20 mA 4 Channel 1 Channel Purge Motor Unit Power Consumption Materials PVDF

 Open the catalog to page 1

All DXG Ltd. catalogs and technical brochures

  1. LSM-30

    1  Page

  2. GGA-70-1

    1  Page

  3. CEMS

    1  Page

  4. DGA-X Catalog

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.