Product catalog summary
System Components: The system includes a main unit, probe, power distribution panel, purge motor unit, master flange, and cables. Optional components include a probe protector, Teflon coated probe, and an Auto Calibration Unit (ACU). The system is rated IP66 or NEMA 4X and includes a regulator, valve, and calibration gas.
Certificates and Approvals: The system has type approval in Korea, TUV certification in Germany, CPA and CCEP in China, and EAC and PAC in Russia.
Features: The system measures NOx, SO2, and NH3 using Differential Optical Absorption Spectroscopy (DOAS) with a minimum measuring unit of 0.1 ppm. It offers high accuracy (< ±1% FS), repeatability, and a response time of less than 5 seconds. The measuring ranges are SO₂: 0~50 to 0~2000 ppm, NOx: 0~40 to 0~2000 ppm, and NH3: 0~10 to 0~50 ppm. The system operates in the UV range (200-400nm) for precision and minimal moisture interference.
Options: The DGA-X can be equipped with an ACU for real gas calibration or a separated control unit.
Other Specifications: Operating temperature ranges from -20 to +55 °C, with gas temperatures up to +900 °C. Communication interfaces include RS232, 422, 485, LAN (Ethernet), and Hart. The system features a 7" LCD touch screen for display and input. Dimensions are W300 x D380 x H420 mm, with a weight of 22 kg and power consumption of 500 W. The probe is made of SUS 316L or SUS 316Ti, with adjustable lengths from 0.5 to 2.5 m.
Purge System: The purge system dimensions are W183 x H367.5 x L153 mm, with a weight of 13 kg and power consumption of 100 W. It requires instrument air consumption of 8.4 ㎥/h for the analyzer and 60 ㎥/h for the probe.
Explosion-Proof Features: The DGA-X is available in an explosion-proof model, reducing the need for an explosion-proof shelter and saving costs and space.
See more

Catalog excerpts

DGA-X Catalog-1

Technical Specifications Measured Components SO2, NO, NO2, NH3 Measurement Principles Differential Optical Absorption Spectroscopy (DOAS) System Components Main Unit / Probe / Power Distribution Panel / Purge Motor Unit / Master Flange / Cables Min. Measuring Unit 0.1 ppm Accuracy < ±1% FS Span Drift (2 hours) < ±1% FS Repeatability < ±1% FS Probe Protector / Teflon Coated Probe ACU (Auto Calibration Unit) IP66 or NEMA 4X Regulator & Valve / Calibration Gas Response Time < 5 seconds Certificates Approvals Type Approval (Korea) TUV (Germany) CPA, CCEP (China) EAC, PAC (Russia) 01 Measures in the low wavelength UV range (200400nm) for high precision and minimal moisture interference 02 Utilizes the Differential Optical Absorption Spectroscopy (DOAS) method, eliminating the need for calibration 03 Selectively measures two gases out of NOx, SO2, and NH3 simultaneously 04 Enables individual NO and NO2 measurements without the need for a NOx Converter 05 Optional addition of a standard gas calibration device

 Open the catalog to page 1
DGA-X Catalog-2

Options DGA-X with ACU (Real Gas Calibration) Options DGA-X (Separated Control Unit) Other Specifications Measurement Conditions (Dperatmg _20 ~ +55 °C Probe Communication Analog Outputs Digital Outputs Digital Inputs Display & Input Device 2 Channel, 4 ~ 20 mA 4 Channel 2 Channel 7" LCD Monitor (Touch Screen) Materials Length Measurement Section Length Gas Flow Rate Weight Purge Motor Temperature Sensor Dimension & Power Supply Dimensions Weight Enclosure Rating Voltage Power Consumption Purge Motor Unit Dimensions Weight Voltage Power Consumption

 Open the catalog to page 2
DGA-X Catalog-3

Measurement Principles Differential Optical Absorption Spectroscopy (DOAS) Zero Drift (2 hours) < ±1% FS Span Drift (2 hours) < ±1% FS Response Time < 5 seconds System Components Main Unit / Probe / Junction Box / Purge System / Master Flange / Cables Features Options Purge Motor Unit (Air pump, Air filter, Air hose) 01 Explosion-proof model of the DGA-X 02 In-situ explosion-proof design reduces the need for a explosion-proof shelter, saving costs and minimizing space constraints 03 Measures in the low wavelength UV range (200400nm) for high precision and minimal moisture interference 04 Utilizes...

 Open the catalog to page 3

All DXG Ltd. catalogs and technical brochures

  1. LSM-30

    1  Page

  2. GGA-70-1

    1  Page

  3. CEMS

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.