Overview: This document provides comprehensive technical details on DVP side channel blowers, focusing on their construction, benefits, applications, and operational guidelines. It includes specifications for both single and double-stage blowers, highlighting their oil-free operation and suitability for non-explosive gas mixtures.
Specifications: The blowers are equipped with a two-pole, asynchronous motor with IP55 protection, adhering to IEC 34.1 standards. They are available in single-phase and three-phase models, with detailed power ratings and dimensions provided in tables.
Construction Features: The blowers have a single-block design with the motor directly attached to the blower body. The impellers are mounted on the drive shaft, and the assembly is made from aluminum casting, ensuring a compact and lightweight structure.
Advantages: The blowers offer maintenance-free operation, no contamination of conveyed fluids, silent operation, compact size, easy installation, and stability without vibrations.
Applications: Suitable for various applications such as pneumatic conveying, water treatment, galvanization baths, aquarium oxygenation, industrial ovens, printing machines, and agricultural spraying. They are designed for clean air or non-aggressive gases, with a maximum operating temperature of 40°C.
Operational Guidelines: Users should not exceed the maximum pressure (Dp) indicated in diagrams and tables. Relief valves should be installed to prevent overpressure, and filters are recommended to remove solid components from the intake fluid.
Additional Information: The document includes selection charts and dimension tables for different blower models, providing detailed measurements and performance data to assist in selecting the appropriate blower for specific applications.
Specifications for Valves: The document details technical specifications for vacuum and pressure change-over valves used in side channel blowers, noting a pressure drop of approximately 10 mbar, varying with flow rate.
Procedures: Valves allow inversion of suction or blowing flow without reversing rotation direction, using a motorized electric actuator compliant with Directive 2004/108/CE, powered by AC/DC. A neutral position isolates blower flow without stopping the machine.
Standards and Compliance: Valves comply with Directive 2004/108/CE and have a protection class of EN 60529 IP 55.
Recommendations: Installation requires adjusting the fixation bores of inlet and outlet flanges to a distance of 125 mm for fitting the change-over valve on specific blower models.
Key Data from Diagrams: Assembly diagrams for vacuum and pressure relief valves, change-over valves, and filters specify connection points for user systems, blowers, and air inlets or outlets.
Critical Information: Nominal operating flow rate is 300 m³/h, direction of rotation is -45° / 0 / +45°, power supply is V 24±10% AC/DC, duty cycle is 100%, minimal time between cycles is 10 seconds, and average swap time is 0.5 seconds.
Accessories: Includes mesh filters and various valve models with specific catalogue codes for ordering.
See more

Catalog excerpts

SINGLE STAGE BLOWER TSC.40 40m3/h 0,2kw 115/230V 50-60Hz-1

Turbine a canale laterale Seitenkanalverdichter Side chanel blowers Turbinas de canal lateral

 Open the catalog to page 1
SINGLE STAGE BLOWER TSC.40 40m3/h 0,2kw 115/230V 50-60Hz-2

Turbine a canale laterale. Side channel blowers. Turbina de canal lateral. Le turbine a canale laterale mono e do pp io s t ad io D V P so n o c on ce pite pe r comp rimer e o a spir are , ga s o mis c ele no n esplosive. I l funzionamento senza alcuna lubrificazione, garantisce l'assenza d i o lio da i f luid i co mpr es si. L e t u rb ine so no ac c op pia t e direttamente al motore elettrico 2 poli (2800/3300giri/min) trifase o monofase, asincrono 50/60 Hz, chiusi con grado di protezione IP 55 secondo le norme IEC 34.1 e dotato d i p ro te t to re t er mic o (P TO ) sull'avvolgimento. E '...

 Open the catalog to page 2
SINGLE STAGE BLOWER TSC.40 40m3/h 0,2kw 115/230V 50-60Hz-3

Dimensioni turbine monostadio. Abmessungen einstufiger Verdichter. Overall dimensions for sigle stage blowers. Dimensiones turbinas de una etapa. Turbine con motore monofase. Modello Modell Model Modelo Codice Art-Nr. Code Codigo Turbine con motore trifase. Modello Modell Model Modelo Codice Art-Nr. Code Codigo Blowers with single phase motor. Blowers with three phase motor. Turbinas con motor monofásico. Turbinas con motor trifásico.

 Open the catalog to page 3
SINGLE STAGE BLOWER TSC.40 40m3/h 0,2kw 115/230V 50-60Hz-4

Diagramma di selezione turbine monostadio monofase usate in aspirazione. Auswahldiagramm Vakuumbetrieb für einstufige Verdichter mit 1-Phasen-Motor. E Gráfico curvas para selección turbinas de una etapa monofásico en aspiración. Selection chart for single stage single phase motor blowers for suction usage. Curve riferite alla pressione di 1013mbar (ass.) e temp. 20°C (tolleranza ±10%). Modello Modell Model Modelo Codice Art-Nr. Code Codigo Die Kurve sich aufeinenDrickvon 1013 mbar(abs.) und einer Temperatur von 20°C (toleranz ±10%). N.B. Non superare in nessun caso il massimo Dp indicato nei...

 Open the catalog to page 4
SINGLE STAGE BLOWER TSC.40 40m3/h 0,2kw 115/230V 50-60Hz-5

Diagramma di selezione turbine monostadio monofase usate in compressione. Auswahldiagramm Druckbetrieb für einstufige Verdichter mit 1-Phasen-Motor. Selection chart for single stage single phase motor blowers for compression usage. Gráfico curvas para selección turbinas de una etapa monofásico en compresión. Curve riferite alla pressione di 1013mbar (ass.) e temp. 20°C (tolleranza ±10%). Modello Modell Model Modelo Codice Art-Nr. Code Codigo Die Kurve sich aufeinen Drickvon 1013mbar(abs.) und einer Temperatur von 20°C (toleranz ±10%). N.B. Non superare in nessun caso il massimo Dp indicato nei...

 Open the catalog to page 5
SINGLE STAGE BLOWER TSC.40 40m3/h 0,2kw 115/230V 50-60Hz-6

Diagramma di selezione turbine monostadio trifase usate in aspirazione. Auswahldiagramm Vakuumbetrieb für einstufige Verdichter mit 3-Phasen-Motor. Selection chart for sigle stage three phase motor blowers for suction usage. E Gráfico curvas para selección turbinas trifásico de una etapa en aspiración. Curve riferite alla pressione di 1013mbar (ass.) e temp. 20°C (tolleranza ±10%). Modello Modell Model Modelo Codice Art-Nr. Code Codigo Die Kurve sich aufeinenDrickvon 1013 mbar(abs.) und einer Temperatur von 20°C (toleranz ±10%). N.B. Non superare in nessun caso il massimo Dp indicato nei grafici...

 Open the catalog to page 6
SINGLE STAGE BLOWER TSC.40 40m3/h 0,2kw 115/230V 50-60Hz-7

Diagramma di selezione turbine monostadio trifase usate in compressione. Auswahldiagramm Druckbetrieb für einstufige Verdichter mit 3-Phasen-Motor. Selection chart for single stage three phase motor blowers for compression usage. Gráfico curvas para selección turbinas trifásico de una etapa en compresión. Curve riferite alla pressione di 1013mbar (ass.) e temp. 20°C (tolleranza ±10%). Modello Modell Model Modelo Codice Art-Nr. Code Codigo TSC.40 9402050 TSC.80 9402051 TSC.150 9402052 TSC.150-1 9402053 TSC.150-1 9402054 TSC.210 9402055 TSC.310 9402056 TSC.310-1 9402057 TSC.310-2 9402058 TSC.550...

 Open the catalog to page 7
SINGLE STAGE BLOWER TSC.40 40m3/h 0,2kw 115/230V 50-60Hz-8

Dimensioni turbine doppio stadio. Overall dimensions for double stage blowers. Abmessungen zweistufiger Verdichter. Dimensiones turbinas de dos etapas. Turbine con motore monofase. Modello Modell Model Modelo Codice Art-Nr. Code Codigo Turbine con motore trifase. Modello Modell Model Modelo Codice Art-Nr. Code Codigo Blowers with single phase motor. Turbinas con motor monofásico. Blowers with three phase motor. Turbinas con motor trifásico.

 Open the catalog to page 8
SINGLE STAGE BLOWER TSC.40 40m3/h 0,2kw 115/230V 50-60Hz-9

Diagramma di selezione turbine doppio stadio monofase usate in aspirazione. Auswahldiagramm Vakuumbetrieb für zweistufige Verdichter mit 1-Phasen-Motor. Selection chart for double stage single phase motor blowers for suction usage. 300 E Gráfico curvas para selección turbinas monofásico de dos etapas en aspiración. Curve riferite alla pressione di 1013mbar (ass.) e temp. 20°C (tolleranza ±10%). Modello Modell Model Modelo Codice Art-Nr. Code Codigo Die Kurve sich aufeinen Drickvon 1013mbar(abs.) und einer Temperatur von 20°C (toleranz ±10%). Diagramma di selezione turbine doppio stadio monofase...

 Open the catalog to page 9
SINGLE STAGE BLOWER TSC.40 40m3/h 0,2kw 115/230V 50-60Hz-10

Diagramma di selezione turbine doppio stadio trifase usate in aspirazione. Auswahldiagramm Vakuumbetrieb für zweistufige Verdichter mit 3-Phasen-Motor. Selection chart for double stage three phase motor blowers for suction usage. Gráfico curvas para selección turbinas trifásico de dos etapas en aspiración. Curve riferite alla pressione di 1013mbar (ass.) e temp. 20°C (tolleranza ±10%). Modello Modell Model Modelo Codice Art-Nr. Code Codigo Die Kurve sich aufeinenDrickvon 1013 mbar(abs.) und einer Temperatur von 20°C (toleranz ±10%). N.B. Non superare in nessun caso il massimo Dp indicato nei...

 Open the catalog to page 10
SINGLE STAGE BLOWER TSC.40 40m3/h 0,2kw 115/230V 50-60Hz-11

Diagramma di selezione turbine doppio stadio trifase usate in compressione. Auswahldiagramm Druckbetrieb für zweistufige Verdichter mit 3-Phasen-Motor. Selection chart for double stage three phase motor blowers for compression usage. Gráfico curvas para selección turbinas trifásico de dos etapas en compresión. [m3 /h] Curve riferite alla pressione di 1013mbar (ass.) e temp. 20°C (tolleranza ±10%). Modello Modell Model Modelo Codice Art-Nr. Code Codigo N. B. No n s uper are in nes su n caso il massimo Dp indicato nei grafici e in tabella in funz io ne della potenza installata; applicare eventualmente...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.