Overview: The document provides technical specifications and selection charts for
single-stage blowers with both single-phase and three-phase motors. It includes dimensions, model codes, and performance data for various models.
Specifications: The document lists dimensions and model codes for different blower models, including TSB.40, TSB.80, TSB.150, TSB.210, TSB.310, TSB.550, and TSB.1100. Each model is detailed with measurements such as height, width, and length, as well as connection sizes.
Performance Charts: Selection charts are provided for both suction and compression usage of blowers. These charts indicate the performance of blowers at different frequencies (50Hz and 60Hz) and highlight the maximum pressure limits that should not be exceeded.
Safety Recommendations: The document emphasizes the importance of not exceeding the maximum pressure (p) indicated in the charts and tables. It recommends installing a relief valve if necessary to prevent overpressure, with references to further details on page 112 and 113.
Technical Data: The document includes detailed technical data such as power requirements, airflow rates (m3/h), pressure levels (mbar), and noise levels (dB(A)) for each blower model. It also specifies the voltage and current requirements for both 50Hz and 60Hz operations.
Key Notes: All performance curves are based on a standard pressure of 1013 mbar (abs) and a temperature of 20°C, with a tolerance of ±10%. This standardization ensures consistency in performance evaluation across different models.