1. Catalogs
  2. DURAG GROUP
  3. DURAG GROUP Product Overview Emission Monitoring

DURAG GROUP Product Overview Emission Monitoring

DURAG GROUP Product Overview Emission Monitoring
1 / 20 PagesView full catalog

DURAG GROUP Product Overview Emission Monitoring

Product catalog summary
Product Overview
This document provides an overview of smart solutions for combustion and environmental monitoring, focusing on emission and ambient monitoring, as well as environmental and process data management systems.
Emission Monitoring
The document details various devices for measuring dust, soot, mercury, and other emissions. It includes specifications for different models such as D-R 220, D-R 290, D-R 320, and others, highlighting their measuring principles, certifications (TÜV, DIN EN 15267-3, US EPA, etc.), and features like automatic zero and control point checks, and remote control capabilities.
Ambient Monitoring
Ambient monitoring devices are designed to measure dust concentrations in various environments. The document outlines the measuring principles, system components, and applications for devices like the D-R 320 and D-R 300, emphasizing their ease of installation, maintenance, and suitability for different industrial applications.
Environmental and Process Data Management Systems
The document describes systems for managing environmental and process data, focusing on their ability to provide accurate and reliable measurements for compliance and process optimization. It includes details on system components, features, and applications in industries such as waste incineration, cement manufacturing, and power plants.
Key Features and Approvals
Each device is equipped with features like automatic contamination control, remote access, and digital interfaces. They are approved and certified according to various international standards, ensuring their reliability and accuracy in different industrial settings.
Specifications:
- Operating temperature range for equipment: -20 to 50 °C.
- Probe material options: stainless steel, Hastelloy.
- Power supply: 230/400 V, 50 Hz, 3x 16 A.
- Protection class: IP65.
- Measuring gas temperature: max. 280 °C.
- Measuring air flow rate: 8 to 10 m³/h.
- Flange size: DN 80 PN 6.
- Digital contacts: 6x max. 35 V, 0.4 A.
- Digital input: optional via switching contact.
System Components:
- Dust concentration monitor for wet gases.
- Continuous extractive dust concentration measurement using the scattered light principle.
- Includes purge air, diluting air heating, injector air fan, probe heating, and solenoid valve.
Features:
- Automatic zero correction.
- Pre-calibrated, unaffected by particle size, color, or moisture.
- Isokinetic sampling.
- Measurement of very low dust concentrations.
Applications:
- Emission dust measurement after wet scrubbers.
- Coal and oil-fired power stations.
- Waste incineration plants.
- Sewage sludge incineration plants.
- Heavy metal analysis.
Approvals:
- Suitability-tested by RW TÜV.
Options:
- Heated dilution line for high dust concentrations.
- Dust sampling option for heavy metal analysis.
- Special design for toxic and explosive gases.
Measuring Principle:
- Exhaust gas is extracted and diluted, passing through a filter.
- A 14C source irradiates the particle-laden filter spot.
- Absorption by dust is measured and compared with an empty filter spot.
Filter Monitor:
- Uses the triboelectric effect to determine dust loads.
- Suitable for monitoring bag filters and dust extraction plants.
- Not suitable for use directly behind electrostatic precipitators.
Combined Probe Sensor:
- Measures dust concentration, volume flow, temperature, and absolute pressure.
- Compact design with no moving parts.
- Automatic zero and reference point check.
Automatic Sampling Device:
- Portable system for gravimetric dust measurements.
- Compliant with EN 13284-1, VDI 2066, EN ISO 9096, and US-EPA Method 5.
Total Mercury Analyser:
- Continuous mercury analysis in smoke gas.
- High operational safety and low maintenance.
- Remote access and automatic calibration module available.
Ambient Air Dust Concentration Monitor:
- Measures smallest concentration of particles in ambient air using beta-ray absorption.
- Certified for PM2.5 or PM10 measurement.
- Cost-efficient with low filter tape consumption.
- Easy integration into existing air quality monitoring networks.
Overview: The document provides detailed technical specifications and applications for various DURAG measurement and data handling systems, focusing on dust concentration, volume flow, and environmental data management.
Dust Measurement Systems: These systems are designed for long-term ambient dust concentration studies, dust measurement at waste sites, and in air ducts. They are TÜV Rheinland tested and comply with European standards.
Sample Probe Heater: Optional components include a sample inlet, temperature and humidity measurement, and a GM counter tube. The system includes a filter adapter, supply reel, and flow-meter for data processing and control.
D-ISC 100 Operating Unit: This unit supports up to eight sensors, offering easy setup, remote support, and modular design. It features a large display and USB interface for local operation.
D-FL 100 Volume Flow Measuring System: Utilizes differential pressure principles for reliable gas velocity measurement, even at high temperatures. It is certified and offers low maintenance with remote operation capabilities.
D-FL 220 Acoustic Measuring System: Uses ultrasonic pulses for non-contact measurement of gas velocity and volume flow, suitable for wet and aggressive emissions. It is TÜV tested and certified.
D-EMS 2000 Data Handling System: A modular system for managing environmental and process data, certified according to European and US standards. It supports various data types and offers extensive data storage and communication capabilities.
Applications and Approvals: The systems are suitable for various industrial applications, including waste incineration and emissions monitoring. They are approved by TÜV and comply with multiple international standards.
Contact Information: The document lists contact details for DURAG offices worldwide, including locations in Germany, India, Korea, Brazil, China, UAE, France, Italy, Russia, USA, Japan, and the UK.
See more

Catalog excerpts

DURAG GROUP Product Overview Emission Monitoring-1

Product Overview Emission Monitoring Ambient Monitoring Environmental and Process Data Management Systems smart solutions for combustion and environment

 Open the catalog to page 1
DURAG GROUP Product Overview Emission Monitoring-2

Devices for measuring emissions and immissions Measurement Dust/ Opacity Measuring principle Backward Scattering DURAG Group Device Total Mercury Ambient Dust Forward Scattering Automatic zero and control point Automatic soiling correction Fail safe shutters Range switching Remote control unit smoke spot number Detection limit @ stack Ø 1 m Detection limit @ stack Ø 5 m Measuring ranges Sample collection/ heavy metal analysis Comparison of emission dust monitors according to application criteria Measuring range mg/m3 Duct diameter

 Open the catalog to page 2
DURAG GROUP Product Overview Emission Monitoring-3

D-R 320 Dust monitor New generation stray light dust monitor for low to medium dust concentrations Measuring principle System components ●● Easy installation on standard flange ●● Easy start-up without adjustment ●● Automatic background compensation without light absorber ●● Automatic zero and reference point check ●● Automatic contamination control and correction ●● Integrated purge air monitoring and purge air control ●● Minimum maintenance ●● Remote access possible ●● Digital interface according to VDI 4201-3 The D-R 320 is based on the back-scattered light principle. Thereby the light of...

 Open the catalog to page 3
DURAG GROUP Product Overview Emission Monitoring-4

Measuring device for smoke spot number The D-R 300 operates according to the scattered light method. The modulated light from a halogen lamp illuminates the dust particles in the exhaust duct. The scattered light reflected from these particles is measured and assessed. Extremely sensitive device for measuring smoke spot number Specifications ●● Measuring range: smoke spot number 0-3. Limit value II can be set as delayed disconnected contact ●● Calibration: VDI 2066, part 8. Features ●● In-situ measurement directly in the flue gas flow ●● Automatic system tests and correction of measured values...

 Open the catalog to page 4
DURAG GROUP Product Overview Emission Monitoring-5

D-R 290 Dust and opacity monitor Standard system for plants with small to medium dust concentrations Measuring principle System components ●● Contactless measurement ●● Extremely powerful and stable super-wide band diode (SWBD) light source ●● New SMD electronics with digital Modbus RTU interface ●● Automatic zero and reference point check ●● Automatic contamination control and correction ●● Easy adjustment without additional equipment ●● Extremely low maintenance ●● Remote access possible The device operates using the double-pass method according to the auto-collimation prin­ ciple. The light...

 Open the catalog to page 5
DURAG GROUP Product Overview Emission Monitoring-6

D-R 220 Dust and opacity monitor Ideally suited for monitoring medium to high dust concentration on smaller plants and in process applications Measuring principle ●● Automatic self check ●● Extremely low maintenance thanks to durable LED ●● Remote access possible ●● Cost-efficient and space-saving measuring system in the well-known DURAG quality The device operates using the double-pass method according to the auto-collimation prin­ ciple. The light beam traverses the measuring distance twice. The attenuation of the light beam by the dust content in the measuring section is measured and evaluated....

 Open the catalog to page 6
DURAG GROUP Product Overview Emission Monitoring-7

D-R 800 Dust monitor Scattered light dust monitor to measure small to medium dust emissions Measuring principle System components ●● Easy installation on one side of the duct ●● Easy installation, no alignment needed ●● Long lifetime as there are no moving parts inside the duct ●● Probe with corrosion resistant nano-tech coating ●● Automatic zero and reference point check ●● Automatic contamination control and correction The D-R 800 works according to the principle of forward scattering. The concentrated and modulated light of a laser diode penetrates the measuring volume. The forward-scattered...

 Open the catalog to page 7
DURAG GROUP Product Overview Emission Monitoring-8

D-R 820 F Dust concentration monitor for wet gases Measuring principle A defined partial current is withdrawn from the exhaust gas current. This partial current is continuously heated and diluted with clean, heated air directly in the sampling probe. This immediately lowers the relative moisture and aerosols get evaporated in the heated System for continuous extractive dust concentration ­ easurement m in accordance with the scattered light principle probe. The partial current is optically measured in the measuring chamber. The signal is corrected by the measured dilution ratio and is thus a...

 Open the catalog to page 8
DURAG GROUP Product Overview Emission Monitoring-9

Extractive dust concentration monitor ●● Measuring device with PLC control in protective cabinet ●● Heated sample probe with titanium sample nozzle ●● Heated sampling line ●● Filter tape in gas-proof filter holder Dust monitor especially for wet flue gases and for the monitoring of blast furnace gas Options ●● Heated dilution line for high dust concentrations or after wet scrubbers ●● Dust sampling option for heavy metal analysis ●● Special design F-904-20/BFG for measurement of the dust concentration in toxic and explosive blast-furnace or converter gas with shut-off valves for the sample gas...

 Open the catalog to page 9
DURAG GROUP Product Overview Emission Monitoring-10

D-FW 230 231 240/Ex Filter monitor Filter monitor for ­ fficiency e monitoring after filter plants and for continuous dust measuring in dry emissions Compact and rugged design Good price/performance ratio Ideal for monitoring bag filters Minimal maintenance required Early detection of filter malfunctions Savings in cost, as no preventative filter exchange is necessary Applications ●● Power stations ●● Bag filter plants of all types ●● Dust extraction plants in the production industry ●● Waste incineration plants ●● Crematoriums ✖ Not suitable for use directly behind electro­static precipitators...

 Open the catalog to page 10
DURAG GROUP Product Overview Emission Monitoring-11

D-RX 250 Combined probe ­sensor Single rod measurement probe for simultaneous measurement of - Dust concentration [mg/Nm³] - Volume flow [Nm³/h] - Temperature [°C] - Absolute pressure [hPa] Measuring principle ●● Only one probe/ installation opening in the exhaust gas channel ●● Compact design ●● No moving parts ●● Automatic zero and reference point check ●● The dust concentration is determined according to the triboelectric measuring principle. The tribo probe measures the electric charge of the impinging particles. ●● The measurement of the volume flow is based on the mechanical action principle....

 Open the catalog to page 11

All DURAG GROUP catalogs and technical brochures

  1. D-LX 201

    6  Pages

  2. D-LX 110

    6  Pages

  3. D-EMS 2020

    6  Pages

  4. D-ZL

    1  Page

  5. D-LX 200

    4  Pages

  6. D-LX 201/721

    6  Pages

  7. D-LX 100

    1  Page

  8. D-HG 500

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.