DURAG data systems data CEMS
12Pages

{{requestButtons}}

Catalog excerpts

DURAG data systems data CEMS - 1

DURAG GROUP a Multi-dimensional Mathematical Modeling (MdM2) Predictive Emission Monitoring System (PEMS)

Open the catalog to page 1
DURAG data systems data CEMS - 2

The Challenge: Emissions Regulations Governments around the world have implemented or are working on stricter emissions regulations to measure and control the level of emissions by industrial processes. These regulations will require operators to monitor, self-certify and justify emissions of NOX , CO, CO2 , SO2 and unburned hydrocarbons to their country’s environmental agency. Predictive Emission Monitoring Systems, designed in accordance with specifications around the world, including US EPA 40 CFR Part 60 and 40 CFR Part 75, help to maintain emissions compliance and meet data reporting...

Open the catalog to page 2
DURAG data systems data CEMS - 4

Industry Independent Applications PEMS solutions are industry independent and are able to deal with emissions from many different applications. However, fuels should not vary in their calorific values and composition.Typically they a used for gas and oil-fired plants in the utility, petrochemical, chemical and steel sector or other industrial plants or municipal sites. In particular they are tailored for: ► Gas- or liquid-fired emission sources ► Reciprocal Internal Combustion Engines (RICE) ► Regenerative Thermal Oxidizers Suitable Fuel Types include:

Open the catalog to page 4
DURAG data systems data CEMS - 5

The DURAG Predictive Emission Monitoring Systems Solution The DURAG PEMS (dataCEMS) solution uses a Multidimensional Mathematical Modeling (MdM2) technology incorporating empirical models suitable for pollutants such as NOX, CO or O2 as well as first principle knowledge, regression type analysis or formula calculation for CO2 or stack flow to provide a continuous and real-time monitoring of emissions. PEMS define the relationship between a number of characteristic parameters of an emission source and the corresponding emission concentration. By employing historical paired emissions and...

Open the catalog to page 5
DURAG data systems data CEMS - 6

Sensor Validation Methodology (SVM) The heart of dataCEMS is a Sensor Validation Methodology that meets the rigorous requirements of US EPA 40 CFR Part 60, Appendix B to Part 60 – Performance Specifications (PS-16) to continue to operate in the event of sensor failure. This requires a methodology to detect sensor failures or drifts and if possible compensate for those failures which is easily achieved with the dataCEMS Sensor Validation Methodology (SVM). It performs a sensor validation for all input parameters once per minute or once per prediction cycle. One of the main advantages of a...

Open the catalog to page 6
DURAG data systems data CEMS - 8

PEMS Features & Benefits DURAG PEMS solutions: the CAPEX and OPEX Saver! rocess insight P PEMS is a viable diagnostic tool to lower emissions and to improve combustion efficiency. igh performance with low investment H PEMS can accomplish the same accuracy and quality of emissions data of a CEMS with around half of the initial costs. Return on investment (ROI) is usually achieved within a couple of years. A PEMS solution provides reliable emission prediction at all times with a data availability of more than 99 %. operational and maintenance cost Low PEMS solutions reduce manpower...

Open the catalog to page 8
DURAG data systems data CEMS - 9

Complete Compliance Monitoring Solutions DURAG PEMS solutions can either be used as standalone versions or as fully integrated in the modular and adaptable D-EMS 2020 environmental and process data management system. Both solutions perfectly meet the demand of today’s customers of a software product. The D-EMS 2020 system fulfills all customer needs towards a modern, flexible and easy to use user interface. It provides comprehensive reporting and visualization options and communicates with all types of plant control systems as various types of fieldbus and software interfaces are supported....

Open the catalog to page 9
DURAG data systems data CEMS - 10

Why DURAG DURAG has more than 40 years of experience in supplying soft- and hardware products and solutions for emissions data evaluation. Our dedicated team of experts will support you in designing your PEMS solution including full-fledged data acquisition and handling systems (DAHS). One-stop shop for reliable products that fit your process Consulting Expert service Applications-know-how Customized solutions Support Prompt, thorough & competent 24/7 on-call service Production Made in Germany Products that fit your process Service Qualified service technicians DURAG GROUP Training...

Open the catalog to page 10
DURAG data systems data CEMS - 11

DURAG Sales and Marketing GmbH & Co. KG Kollaustraße 105 22453 Hamburg, Germany Tel. +49 40 55 42 18-0 Fax +49 40 58 41 54 E-Mail: info@durag.de DURAG India Instrumentation Private Limited #27/30, 2nd Main Road Industrial Town, Rajajinagar Bengaluru 560 044, India Tel. +91 80 2314 5626, 2301 1700 Fax +91 80 2314 5627 E-Mail: info@duragindia.com DURAG Korea Office RM #1131, Manhattan Building, 36-2, Yeouido-Dong, Yeongdeungpo-Gu, Seoul, Korea Tel. +82 2 761 8970 Fax +82 2 761 8971 E-Mail: info@durag-group.co.kr DURAG Brazil DURAG Siena do Brasil Ltda Rua Vinte e Dois de Agosto, 66 Diadema -...

Open the catalog to page 11
DURAG data systems data CEMS - 12

VEREWA – A Brand of DURAG GmbH Kollaustraße 105 22453 Hamburg, Germany Tel. +49 40 55 42 18-0 Fax +49 40 58 41 54 E-Mail: verewa@durag.de DURAG process & systems technology – A Brand of DURAG GmbH Kollaustraße 105 22453 Hamburg, Germany Tel. +49 40 55 42 18-0 Fax +49 40 58 41 54 E-Mail: info@durag-process.de A Brand of DURAG data systems GmbH Branch Office Austria Lastenstraße 36, City Tower 2 4020 Linz, Austria Tel. +43 732 60 99 60-0 Fax +43 732 60 99 60-4 E-Mail: office@utas.at Hegwein GmbH Am Boschwerk 7 70469 Stuttgart Germany Tel. +49 711 135 788-0 Fax +49 711 135 788-5 E-Mail:...

Open the catalog to page 12

All DURAG Group catalogs and technical brochures

  1. D-LX 110

    6 Pages

  2. D-LX 201

    6 Pages

  3. D-EMS 2020

    6 Pages

  4. D-ZL

    1 Pages

  5. AAL 75

    1 Pages

  6. D-LX 200

    4 Pages

  7. D-LX 201/721

    6 Pages

  8. D-LX 100

    1 Pages

  9. D-HG 500

    4 Pages